Home › Engine / Hybrid System › 2ZR-FXE (HYBRID / BATTERY CONTROL) › ELECTRIC VEHICLE CONVERTER › from 2020.08
RM32K0E _51 Engine / Hybrid System _083958 2ZR-FXE HYBRID / BATTERY CONTROL _0404375 ELECTRIC VEHICLE CONVERTER A

2ZR-FXE HYBRID / BATTERY CONTROL  ELECTRIC VEHICLE CONVERTER  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during HV converter kit removal/installation are shown below.

Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedures Effect/Inoperative Function when Necessary Procedure not Performed Link
Disconnect cable from negative auxiliary battery terminal Memorize steering angle neutral point Panoramic view monitor system (Click here)
Replacement of inverter with converter assembly Resolver learning
·

DTCs are stored

·

Slight vibration at a vehicle speed of 5 km/h (3 mph) or less

·

Shock or vibration during acceleration


·

for NICKEL METAL HYDRIDE BATTERY:

(Click here)

·

for LITHIUM-ION BATTERY:

(Click here)


for SFI system

Replacement of ECM


Perform Vehicle Identification Number (VIN) registration MIL comes on (Click here)

CAUTION:
·
A340386

This vehicle has contains high voltage circuits standardized with orange colored wiring and connectors, so follow the instructions in this manual to perform the procedures correctly.

for NICKEL METAL HYDRIDE BATTERY:

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>PRECAUTION

for LITHIUM-ION BATTERY:

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM (for LITHIUM-ION BATTERY)>PRECAUTION

·

If the correct procedures are not followed according to the instructions in this manual, there is a danger of electric shock from the high voltage circuits.

·
A340358

Be sure to wear insulating gloves when working on high voltage wiring or components.

·

If work is performed without wearing insulating gloves, there is a danger of electric shock.



NOTICE:
A309734

·

If metal shavings are created when bolts are removed from the inverter with converter assembly, remove them using tape or equivalent.

·

Use non-residue type tape.



HINT:

When the cable is disconnected / reconnected to the battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.

·

Learning completes when vehicle is driven

Effect/Inoperative Function When Necessary Procedures are not Performed Necessary Procedures Link

*1: When performing learning using the GTS

Click here(Click here)

Lane tracing assist system Drive the vehicle straight ahead at 35 km/h (22 mph) or more for 5 second or more. (Click here)
Pre-collision system
Simple intelligent parking assist system*1
Parking support brake system*1
Toyota parking assist-sensor system*1

·

Learning completes when vehicle is operated normally

Effect/Inoperative Function When Necessary Procedures are not Performed Necessary Procedures Link
Power door lock control system
·

Back door opener


Perform door unlock operation with door control switch or electrical key transmitter sub-assembly switch. (Click here)
Air conditioning system After the ignition switch is turned to ON, the servo motor standard position is recognized. -



PROCEDURE

Hide G9200 1.REMOVE INVERTER WITH CONVERTER ASSEMBLY

Hide 33829E 4.REMOVE TRANSMISSION CONTROL CABLE BRACKET

Hide 6. VERIFY THAT VOLTAGE OF INVERTER WITH CONVERTER IS 0 V

CAUTION:

Wear insulating gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A376338C01
2.927,0.427 2.698,0.427 2.698,0.427 2.292,0.969 true 3,0.354 3.313,0.552 0.313,0.198 10 false *a
*a Tape


Remove the protective tape from the HV floor under wire opening.


b.
A393691C01
0.313,2.438 0.938,2.438 true 1.375,2.448 2.24,2.448 true 0.135,2.375 0.448,2.531 0.313,0.156 10 false *a 2.281,2.385 2.594,2.542 0.313,0.156 10 false *a
*a Voltage Measurement Position


Using a voltmeter, measure the voltage between the high voltage cable connector terminals.

Standard voltage:

0V


HINT:
·

Use measuring range of DC 750 V or more on the voltmeter.

·

If it is confirmed that high-voltage is not being applied to the inverter with converter assembly, the following procedures can be performed without using insulated tools or gloves.




c.

Apply protective tape to the area that was exposed.

NOTICE:

Use non-residue type tape.



Hide G9200 7.CLEAN INVERTER WITH CONVERTER ASSEMBLY

a.

Using a piece of cloth, clean the outside of the inverter with converter assembly and around the bolts.

NOTICE:

To prevent foreign matter from entering the inverter with converter assembly, make sure that the protective tape is not partially removed.



Hide 8. HOW TO PREVENT STATIC ELECTRICITY

SST
09890-47010  

NOTICE:
·

Static electricity should be eliminated when removing/installing the inverter with converter assembly.

·

Do not touch the electronic components of a circuit board.

·

Keep clothes away from electronic components.

·

Place the inverter with converter assembly and any removed electronic components on SST (antistatic mat).



a.
E104190N03
1.104,0.448 0.615,0.302 0.615,0.302 2.125,0.156 true 0.313,0.24 0.792,0.604 0.479,0.365 10 false SST

Wear an antistatic wrist strap.


b.

Connect the ground clip of the antistatic mat securely to a ground point provided in the workshop or on a workbench (anchor bolt).

HINT:

If the ground clip cable is too short, use an extension cable.



c.

Connect the ground clip of the antistatic wrist strap securely to the specified point of the antistatic mat.


d.

When handling internal components of the inverter with converter assembly, use only antistatic gloves or bare hands to prevent damage from static electricity or the entry of foreign matter.


Hide 9.DRAIN COOLANT (for Inverter)

a.
A393694

Place the inverter with converter assembly on a stand as shown in the illustration.

NOTICE:
·

Make sure to use the stand, otherwise the low voltage connectors or inverter upper cover may be damaged.

·

Make sure to place the inverter with converter assembly on the stand so that the coolant pipes are positioned downward.




b.

Connect the ground clip of the antistatic wrist strap securely to the inverter with converter assembly.


c.
A393692

Remove the 2 caps from the coolant pipes and drain the coolant (for inverter).


d.
A393693

Blow compressed air into the inverter with converter assembly until most all of the coolant (for inverter) is blown out.

NOTICE:
·

Do not damage the coolant pipes.

·

Apply compressed air to the silver colored coolant pipe.



HINT:
·

Use a piece of cloth as shown in the illustration to prevent the coolant (for inverter) from spraying.

·

Cover the air inlet port with a piece of cloth to minimize air leakage.



i.

Install the 2 caps to the coolant pipes.



Hide 10.REMOVE CONVERTER COVER

a.
A376343

Remove the 8 bolts.


b.

Using a screwdriver with its tip wrapped with protective tape, remove the converter cover from the inverter with converter assembly.

A393695C01
4.938,0.885 5.813,1.167 5.813,1.167 6.542,0.896 true 1.083,2.031 1.281,2.031 1.281,2.031 1.438,1.781 false 5.99,3.438 5.833,3.438 5.833,3.438 5.667,3.281 true 5.729,1.198 5.906,1.354 0.177,0.156 10 true *a 0.906,1.958 1.083,2.115 0.177,0.156 10 true *a 6.042,3.354 6.219,3.51 0.177,0.156 10 true *a
*a Protective Tape - -


NOTICE:
·

Do not damage the sealing surfaces of the inverter with converter assembly.

·

Do not touch or allow grease or oil to contact the sealing surfaces of the inverter with converter assembly.

·

Be careful not to damage the sealing surfaces of the inverter with converter assembly.

·

To prevent internal components of the inverter with converter assembly from being damaged, do not insert the screwdriver excessively.




Hide 11.REMOVE SEAL PACKING FROM INVERTER WITH CONVERTER ASSEMBLY

NOTICE:
·

Do not allow any removed seal packing to enter the inverter with converter assembly.

·

Do not touch the circuit board.

·

Do not allow any moisture to come into contact.



a.

Using a finger, remove any seal packing that has seeped into the inverter with converter assembly.

HINT:

Make sure to remove any seal packing which has seeped toward the inside of inverter with converter assembly before installing the seal packing removal cover, otherwise the seal packing may be pushed into the inverter with converter assembly.



b.
A396291

Break off the seal packing removal cover and scraper at each break off line.


c.
A393696C01
0.719,1.854 1,1.854 true 2.427,1.177 2.594,1.177 true 1.594,0.469 1.719,0.156 1.719,0.156 1.854,0.156 true 1.75,3.26 1.875,3.26 1.875,3.26 1.979,2.781 true 0.542,1.771 0.854,1.927 0.313,0.156 10 false *a 1.917,0.073 2.229,0.229 0.313,0.156 10 false *a 2.646,1.104 2.823,1.292 0.177,0.188 10 false *a 1.573,3.177 1.885,3.333 0.313,0.156 10 false *a
*a Tape


Set the seal packing removal cover on the inverter with converter assembly and secure it with tape.

NOTICE:

Make sure that the seal packing removal cover is in secure contact with the inside surface of the inverter with converter assembly without any gaps.



d.
A393697C01
1.51,0.531 1.021,0.094 1.021,0.094 0.885,0.094 true 0.708,0.021 1.021,0.177 0.313,0.156 10 false *a
*a MG Connector Opening


Place the inverter with converter assembly on its side on an antistatic mat as shown in the illustration.

NOTICE:
·

Make sure that the MG connector opening in the inverter with converter assembly is facing upward.

·

Make sure that the inverter with converter assembly is oriented correctly, otherwise seal packing may enter the inverter with converter assembly.




e.

Using a scraper, remove any remaining seal packing from the inverter with converter assembly.

NOTICE:
·

It is not necessary to remove small amounts of seal packing which are not easily scraped off.

A393901C02
2.24,0.958 2.479,0.76 2.479,0.76 2.844,0.76 true 4.5,0.938 4.74,0.74 4.74,0.74 5.146,0.74 true 4.375,1.365 4.615,1.167 4.615,1.167 4.979,1.167 true 1.865,0.083 2.094,0.24 0.229,0.156 10 false *a 4.167,0.083 4.396,0.24 0.229,0.156 10 false *b 2.115,1.542 2.344,1.698 0.229,0.156 10 false *c 4.448,1.563 4.677,1.719 0.229,0.156 10 false *c 2.906,0.688 3.219,0.885 0.313,0.198 10 false *d 5.198,0.656 5.51,0.854 0.313,0.198 10 false *e 5.021,1.083 5.333,1.281 0.313,0.198 10 false *f
*a Correct *b Incorrect
*c Width of Sealing Surface *d Difficult to Remove Seal Packing
*e Peeled Off Seal Packing *f Seal Packing Remaining on Full Width of Sealing Surface


·
A396292

Make sure to use the scraper supplied with the seal packing removal cover.



HINT:

Use the small end of the scraper to remove seal packing from small areas such as bolt holes.



f.

Remove the tape used to secure the seal packing removal cover and then remove any seal packing which was under the tape.


g.

Using a clean piece of cloth, clean the sealing surfaces of the inverter with converter assembly.

NOTICE:
·

Do not use compressed air or a vacuum cleaner to clean the sealing surfaces of the inverter with converter assembly.

·

Do not use non-residue solvent to clean the sealing surfaces of the inverter with converter assembly.




h.
A393699

Remove the seal packing removal cover.

NOTICE:

Make sure that the inverter with converter assembly is oriented correctly, otherwise seal packing may enter the inverter with converter assembly when removing the seal packing removal cover.



i.

Make sure that the inverter with converter assembly is free of foreign matter.


Hide 04899 12.REMOVE HV CONVERTER KIT

NOTICE:
·

Do not touch the circuit board.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.



a.
A393700

Place the inverter with converter assembly on a stand as shown in the illustration.

NOTICE:

Make sure that the inverter with converter assembly is oriented correctly.



b.
A393892C01
1.479,0.167 1.635,0.365 0.156,0.198 10 false 1 1.979,0.156 2.135,0.354 0.156,0.198 10 false 2 1.844,3.042 2,3.24 0.156,0.198 10 false 3
V100135

Bolt (A)
V100136

Bolt (B)


Remove the 3 bolts (A) in the order shown in the illustration.


c.

Remove the 8 bolts (B).


d.
A393702

Disconnect the HV converter kit connector and set it as shown in the illustration.

NOTICE:

Make sure that the wire harness of the connector is engaged to the filter condenser.



e.
A376350

Install 2 HV converter kit installation bolts at the positions shown in the illustration and tighten them in several steps to separate the HV converter kit from the inverter with converter assembly.

NOTICE:
·

Tighten the 2 bolts in several steps.

·

Do not forcibly separate the HV converter kit.

·

In order to prevent any foreign matter from entering the inverter with converter assembly, do not remove the bolts.




f.

Hold the corners of the HV converter kit and remove it as shown in the illustration.

A393703C04
2.323,2.438 2.594,2.198 2.594,2.198 2.771,2.198 true 2.333,3.24 2.604,3 2.604,3 2.781,3 true 0.823,2.948 1.094,2.948 1.094,2.948 1.427,2.625 true 0.813,3.51 1.083,3.51 1.083,3.51 1.417,3.188 true 0.865,2.25 1.125,2.25 1.125,2.25 1.552,2.031 true 4.427,1.25 4.75,1.25 true 4.427,2.281 4.75,2.281 true 5.802,1.219 6.125,1.219 true 5.896,2.427 6.219,2.427 true 0.677,2.188 0.99,2.385 0.313,0.198 10 false *a 2.823,2.146 3.135,2.344 0.313,0.198 10 false *a 2.844,2.948 3.156,3.146 0.313,0.198 10 false *a 0.635,2.875 0.948,3.073 0.313,0.198 10 false *a 0.646,3.438 0.958,3.635 0.313,0.198 10 false *a 6.208,1.167 6.521,1.365 0.313,0.198 10 false *b 6.281,2.375 6.594,2.573 0.313,0.198 10 false *b 4.24,2.229 4.552,2.427 0.313,0.198 10 false *b 4.25,1.208 4.563,1.406 0.313,0.198 10 false *b
*a Do Not Allow Coolant (for Inverter) to Enter *b Hold Here
V100135

Remove in this Direction - -


CAUTION:
·

As there is a coolant passage underneath the HV converter kit, be careful not to spill any coolant (for inverter) into the filter condenser or the holes around the edge of the inverter with converter assembly.

·

If any coolant (for inverter) spills into the filter condenser or the holes around the edge of the inverter with converter assembly, do not reuse the inverter with converter assembly.

·

If any coolant (for inverter) spills onto any area other than the specified areas, remove it with a clean piece of cloth.




g.
A393704C02
0.677,2.802 0.99,2.802 0.99,2.802 1.25,3.031 true 2.354,1.625 2.635,1.813 2.635,1.813 2.885,1.813 true 1.25,1.667 0.969,0.802 0.969,0.802 2.104,1.604 true 1.75,3.188 2.865,3.708 2.865,3.708 2.365,3.177 true 0.781,2.313 1.208,2.313 true 2.458,2.156 2.885,2.156 true 2.458,2.698 2.885,2.698 true 1.344,3.135 1.677,2.646 1.677,2.646 1.927,2.646 true 2.927,1.729 3.125,1.927 0.198,0.198 10 false *a 0.49,2.719 0.688,2.917 0.198,0.198 10 false *a 0.802,0.719 1.031,0.927 0.229,0.208 10 false *b 2.938,2.073 3.167,2.281 0.229,0.208 10 false *b 2.927,2.625 3.156,2.833 0.229,0.208 10 false *b 0.615,2.24 0.844,2.448 0.229,0.208 10 false *b 2.927,3.646 3.156,3.854 0.229,0.208 10 false *b 1.99,2.573 2.219,2.781 0.229,0.208 10 true *b
*a Bolt Contacting Surface
*b Bolt Hole


Remove any metal shavings from the areas around the bolt holes and 2 positions where bolts were installed to separate the HV converter kit, using tape or equivalent.


h.
A376352C02
0,0 0,0 false
V100135

Remove in this Direction


Using a clean scraper, lift the O-ring at the position shown in the illustration and then remove it.

CAUTION:
·

When removing the O-ring, be careful not to spill any coolant (for inverter) into the filter condenser or the holes around the edge of the inverter with converter assembly.

·

If any coolant (for inverter) spills into the filter condenser or the holes around the edge of the inverter with converter assembly, do not reuse the inverter with converter assembly.

·

If any coolant (for inverter) spills onto any area other than the filter condenser or the holes around the edge of the inverter with converter assembly, remove it with a clean piece of cloth.




i.

Clean the O-ring groove of the inverter with converter assembly.

NOTICE:

Make sure that the O-ring groove and coolant passage of the inverter with converter assembly are free of foreign matter.