The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the auxiliary battery removal/installation are shown below.
When the cable is disconnected / reconnected to the battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is driven
Learning completes when vehicle is operated normally
1. PRECAUTION
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When replacing the auxiliary battery, use a new auxiliary battery of the same dimensions with a capacity of 51 Ah or more at a 20-hour rate.
2.DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL
Loosen the nut and disconnect the cable from the negative (-) auxiliary battery terminal.
3.REMOVE AUXILIARY BATTERY
Disengage the 2 claws and open the battery terminal cap in the order shown in the illustration.
| *a | Top View of Claws | - | - |
|
Push Battery Terminal Cap Here |
|
Push |
|
Open | - | - |
Loosen the nut and disconnect the cable from the positive (+) auxiliary battery terminal.
Remove the battery insulator from the auxiliary battery.
Remove the bolt and battery clamp No. 2.
Remove the auxiliary battery from the vehicle.