Home › General › SETUP › WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL › from 2020.08
RM32K0E _V1 General _094707 SETUP _0445407 WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL F

SETUP  WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL  AUTOMATIC LEARNING CHART  


AUTOMATIC LEARNING PERFORMED WHEN CABLE IS DISCONNECTED / RECONNECTED TO BATTERY TERMINAL


When the cable is disconnected / reconnected to the battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.

·

Learning completes when vehicle is driven

Effect/Inoperative Function When Necessary Procedures are not Performed Necessary Procedures Link

*1: When performing learning using the GTS

Click here(Click here)

Lane tracing assist system Drive the vehicle straight ahead at 35 km/h (22 mph) or more for 5 second or more. (Click here)
Pre-collision system
Simple intelligent parking assist system*1
Parking support brake system*1
Toyota parking assist-sensor system*1

·

Learning completes when vehicle is operated normally

Effect/Inoperative Function When Necessary Procedures are not Performed Necessary Procedures Link
Power door lock control system
·

Back door opener


Perform door unlock operation with door control switch or electrical key transmitter sub-assembly switch. (Click here)
Air conditioning system After the ignition switch is turned to ON, the servo motor standard position is recognized. -