The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the instrument panel passenger airbag assembly removal/installation are shown below.
After the power switch is turned off, the radio and display receiver assembly records various types of memory and settings. As a result, after turning the power switch off, make sure to wait at least 120 seconds before disconnecting the cable from the negative (-) auxiliary battery terminal.
When the cable is disconnected / reconnected to the battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is driven
Learning completes when vehicle is operated normally
Use the same procedure for RHD and LHD vehicles.
The following procedure is for LHD vehicles.
1. PRECAUTION
Be sure to read Precaution thoroughly before servicing.
Click hereVehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>AIRBAG SYSTEM>PRECAUTION
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
55401E
2.REMOVE INSTRUMENT PANEL SAFETY PAD SUB-ASSEMBLY
73960A
3.REMOVE INSTRUMENT PANEL PASSENGER AIRBAG ASSEMBLY
|
Deployment Side |
When storing the instrument panel passenger airbag assembly, keep the airbag deployment side facing upward.
Remove the 2 screws.
Disengage the hooks to remove the instrument panel passenger airbag assembly from the instrument panel safety pad sub-assembly.
Do not damage the deployment surface of the instrument panel passenger airbag assembly.
82142A
4.REMOVE NO. 2 INSTRUMENT PANEL WIRE
| *a | Protective Tape |
| *b | Airbag Connector |
| *c | Airbag Connector Lock |
Disengage the clamp.
Using a screwdriver with its tip wrapped in protective tape, release the airbag connector lock.
Disconnect the airbag connector to remove the No. 2 instrument panel wire from the instrument panel passenger airbag assembly.
When disconnecting any airbag connector, take care not to damage the airbag wire harness.