OUTLINE
A dual zone automatic air conditioning system (left and right independent control), manual air conditioning system or heater system is available depending on the specification.
An inside-and-outside dual air layer type air conditioning unit is used depending on the specification.
A Positive Temperature Coefficient (PTC) heater is provided as an additional heater depending on the specification.
HFO-1234yf or HFC-134a refrigerant is used depending on the specification.
SPECIFICATIONS
Performance
| Item | Specification | ||||
|---|---|---|---|---|---|
| Automatic | Manual | Heater | |||
|
*1: Except models with dual air layer type air conditioning unit for RHD *2: Models with dual air layer type air conditioning unit for RHD |
|||||
| Heater | Heater Output | W | 7650*1 | 7650 | 7650 |
| 5450*2 | |||||
| Air Flow Volume | m3/h | 330*1 | 330 | 330 | |
| 365*2 | |||||
| Cooler | Cooling Capacity | W | 7196*1 | 7196 | - |
| 5200*2 | |||||
| Air Flow Volume | m3/h | 505*1 | 505 | - | |
| 505*2 | |||||
Ventilation and Heater Core
| Item | Specification | ||
|---|---|---|---|
|
*1: Except models with dual air layer type air conditioning unit for RHD *2: Models with dual air layer type air conditioning unit for RHD *3: Models with single air layer type air conditioning unit *4: Models with dual air layer type air conditioning unit for LHD |
|||
| Heater Radiator Unit Sub-assembly | Type | Straight Flow Aluminum-II (SFA-II) | |
| Size (W x H x L) | mm (in.) | 233.1 x 148.5 x 28 (9.18 x 5.85 x 1.10)*1 | |
| 222.3 x 120 x 27 (8.75 x 4.72 x 1.06)*2 | |||
| Fin Pitch | mm (in.) | 0.7 (0.03)*1 | |
| 1.8 (0.07)*2 | |||
| Blower Motor with Fan Sub-assembly | Motor Type | DC Motor*1 | |
| DC Ferrite Brushless*2 | |||
| Fan Type | Sirocco | ||
| Fan Size (Dia. x H) | mm (in.) | 156 x 90 (6.14 x 3.54)*3 | |
| Upper Side : 150 x 58 (5.90 x 2.28)*4
Lower Side : 150 x 44.5 (5.90 x 1.75)*4 |
|||
| Upper Side : 122 x 55 (4.80 x 2.17)*2
Lower Side : 125 x 38 (4.92 x 1.50)*2 |
|||
Air Conditioning (Except Models with Heater system)
| Item | Specification | ||
|---|---|---|---|
|
*1: Models for 8NR-FTS engine *2: Models for 3ZR-FAE engine *3: Except models with dual air layer type air conditioning unit for RHD *4: Models with dual air layer type air conditioning unit for RHD *5: Models using HFO-1234yf refrigerant *6: Models using HFC-134a refrigerant |
|||
| Cooler Condenser Assembly | Type | Global Inner-fin Condenser (GIC) | |
| Size (W x H x L) | mm (in.) | 694 x 387.4 x 12 (27.3 x 15.3 x 0.47)*1*3 | |
| 619 x 387.4 x 12 (24.4 x 15.3 x 0.47)*2 | |||
| 690 x 376.2 x 11.5 (27.2 x 14.8 x 0.46)*4 | |||
| Fin Pitch | mm (in.) | 1.2 (0.05)*3 | |
| 2.5 (0.10)*4 | |||
| No. 1 Cooler Evaporator Sub-assembly | Type | Aluminum Brazing Core*3 | |
| Beneficial Refrigerant Stream (BRS)*4 | |||
| Size (W x H x L) | mm (in.) | 250 x 245 x 38 (9.84 x 9.65 x 1.50)*3 | |
| 239.5 x 231 x 38 (9.43 x 9.09 x 1.50)*4 | |||
| Fin Pitch | mm (in.) | 0.05 (0.002)*3 | |
| 3.0 (0.12)*4 | |||
| Compressor with Pulley Assembly | Type | VCS-12E*3 | |
| 6SES12C*4 | |||
| Refrigerant | Type | HFO-1234yf*5 | |
| HFC-134a*6 | |||
MAIN FEATURES
The air conditioning system has the following features:
| Feature | Outline |
|---|---|
|
*1: Models with automatic air conditioning system *2: Models with PTC heater *3: Models with dual air layer type air conditioning unit for RHD *4: Except models with heater system *5: Except models with dual air layer type air conditioning unit for RHD |
|
| High Performance | ·
Neural network control is used so passengers can control the air conditioning accurately for maximum comfort.*1 ·
The blower control has 7 levels in manual mode and 31 levels in automatic mode for more precise control.*1 ·
The Positive Temperature Coefficient (PTC) heater control is used. This system contains a PTC heater (quick heater assembly) that heats the air that has passed through the heater radiator unit sub-assembly to ensure proper heater performance.*2 ·
A pollen removal type clean air filter is used as a clean air filter. |
| Light Weight | A bus connector with a built-in communication/driver IC is used in a lightweight wire harness design to allow a reduced number of wires. The use of this type of connector means that pulse pattern type servo motors can be used.*3 |
| Compact | A semi-center location air conditioning unit in which the No. 1 cooler evaporator sub-assembly*4, heater radiator unit sub-assembly and PTC heater (quick heater assembly)*2 are placed in the vehicle's longitudinal direction is used. |
| Others | The following parts are used to ensure high cooling or heating performance while realizing a compact and lightweight construction.
·
Straight Flow Aluminum (SFA)-II type heater radiator unit sub-assembly ·
Aluminum Brazing Core type No. 1 cooler evaporator sub-assembly*4*5 ·
Beneficial Refrigerant Stream (BRS) type No. 1 cooler evaporator sub-assembly*3 ·
Global Inner-fin Condenser (GIC) Sub-cool Condenser*4 |
PRECAUTION
Precaution for Refrigerant HFO-1234yf
Always use HFO-1234yf as the refrigerant.
Do not charge the system with refrigerant near open flames, as HFO-1234yf is combustible.
When charging the system with refrigerant, make sure the area is well ventilated (especially be careful in areas where the gas can easily accumulate such as under lifts and in garage pits, as the gas is heavier than air).
Follow any local regulations regarding combustible gases.
Be sure to use a refrigerant recovery unit that is compatible with HFO-1234yf systems.
The shape of the service port for refrigerant charging has an exclusive design conforming to international standards for HFO-1234yf to prevent improper refrigerant charging.
Compressor Oil (Models using HFO-1234yf Refrigerant)
Always use VC100YF as the compressor oil.
The oil used for HFC-134a systems (ND-OIL 8) does not work well in HFO-1234yf systems. If the oil used for HFC-134a systems (ND-OIL 8) is used in the HFO-1234yf system, it will result in degradation of the refrigerant and deterioration of resin parts.
When parts of the air conditioning system are removed, quickly block off any areas that are exposed to the outside air with plugs, vinyl tape, etc., as the oil used for HFO-1234yf systems absorbs moisture easily.
Do not allow the compressor oil to spray, as the oil used for HFO-1234yf systems has harmful effects on acrylic resins.
Ignition Switch Expressions
The type of ignition switch used on this model differs depending on the specifications of the vehicle. The expressions listed in the table below are used in this section.
| Expression | Ignition Switch (Position) | Engine Switch (Condition) |
|---|---|---|
| Ignition Switch off | LOCK | Off (Lock) |
| Ignition Switch ACC | ACC | On (ACC) |
| Ignition Switch ON | ON | On (IG) |
| Engine Start | START | On (Start) |