Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
NM32H0E _58 Vehicle Interior _059732 HEATING / AIR CONDITIONING _0292851 AIR CONDITIONING SYSTEM DE DETAILS F

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  DETAILS  COMPRESSOR WITH PULLEY  


CONSTRUCTION


a.

The compressor with pulley assembly is a continuously variable capacity type with a capacity that varies in accordance with the cooling load of the air conditioning.

VCS-12E
Y206775C01
2.083,3.958 2.25,3.958 2.25,3.958 2.833,2.573 true 5.344,3.229 6.177,4.073 6.177,4.073 6.344,4.073 true 1.896,3.865 2.208,4.021 0.313,0.156 10 false *1 6.375,3.969 6.688,4.125 0.313,0.156 10 false *2
*1 Shaft *2 Solenoid Control Valve


6SES12C
Y206776C01
3.594,1.625 3.083,0.667 3.083,0.667 2.917,0.667 true 2.25,0.833 2.417,0.833 2.417,0.833 2.75,1.688 true 1.25,1.167 1.417,1.167 1.417,1.167 2.26,2.427 true 2.083,4.083 2.25,4.083 2.25,4.083 2.875,3.25 true 2.833,4.333 3,4.333 3,4.333 3.469,3.365 true 3.833,4.083 4,4.083 4,4.083 4.25,3.365 true 5.385,2.198 6.167,3.417 6.167,3.417 6.333,3.417 true 4.083,1.667 4.5,0.667 4.5,0.667 4.667,0.667 true 2.719,0.552 3.031,0.708 0.313,0.156 10 false *1 2.052,0.708 2.365,0.865 0.313,0.156 10 false *2 1.073,1.063 1.385,1.219 0.313,0.156 10 false *3 1.896,3.969 2.208,4.125 0.313,0.156 10 false *4 2.646,4.219 2.958,4.375 0.313,0.156 10 false *5 3.635,3.969 3.948,4.125 0.313,0.156 10 false *6 6.375,3.333 6.688,3.49 0.313,0.156 10 false *7 4.708,0.583 5.021,0.74 0.313,0.156 10 false *5
*1 Shoe *2 Crank Chamber
*3 Shaft *4 Lug Plate
*5 Piston *6 Cylinder
*7 Solenoid Control Valve - -




OPERATION


a.

The crank chamber is connected to the suction passage. A solenoid control valve is provided between the suction passage (low pressure) and the discharge passage (high pressure).


b.

The solenoid control valve operates under duty cycle control in accordance with the signals from the air conditioning amplifier assembly.

Y108998C01
1.615,0.323 2.771,0.323 2.771,0.323 3.167,1.167 false 4.198,2.323 4.438,2.323 4.438,2.323 4.573,2.198 false 1.615,1.292 2.24,1.292 2.24,1.292 2.458,1.656 false 1.427,0.219 1.708,0.448 0.281,0.229 10 *1 1.427,1.198 1.708,1.427 0.281,0.229 10 *2 4.021,2.229 4.302,2.458 0.281,0.229 10 *4 4.927,2.917 5.208,3.146 0.281,0.229 10 *5 4.917,0.344 5.198,0.573 0.281,0.229 10 *6 3.625,1.74 3.906,1.969 0.281,0.229 10 *3 3.229,3.198 3.51,3.427 0.281,0.229 10 *3
*1 Suction Passage *2 Crank Chamber
*3 Piston *4 Discharge Passage
*5 Solenoid Control Valve *6 Air Conditioning Amplifier Assembly



c.

When the solenoid control valve closes (the solenoid coil is energized), a difference in pressure is created and the pressure in the crank chamber decreases. Then, the pressure applied to the right side of the piston becomes greater than the pressure applied to the left side of the piston. This compresses the spring and tilts the lug plate. As a result, the piston stroke increases and the discharge capacity increases.

Y108999C01
1.615,0.156 2.771,0.156 2.771,0.156 3.167,1 false 4.198,2.177 4.438,2.177 4.438,2.177 4.573,2.042 false 1.615,1.167 2.24,1.167 2.24,1.167 2.458,1.521 false 1.427,0.052 1.708,0.281 0.281,0.229 10 *1 1.823,2.469 2.104,2.698 0.281,0.229 10 *a 3.771,3.51 4.052,3.74 0.281,0.229 10 *b 1.427,1.073 1.708,1.302 0.281,0.229 10 *2 4.021,2.073 4.302,2.302 0.281,0.229 10 *4 4.917,2.729 5.198,2.958 0.281,0.229 10 *5 4.917,0.188 5.198,0.417 0.281,0.229 10 *6 3.625,1.573 3.906,1.802 0.281,0.229 10 *3 3.229,3.063 3.51,3.292 0.281,0.229 10 *3
*1 Suction Passage *2 Crank Chamber
*3 Piston *4 Discharge Passage
*5 Solenoid Control Valve *6 Air Conditioning Amplifier Assembly
*a Crank Chamber Pressure + Spring Force *b Piston Stroke: Large



d.

When the solenoid control valve opens (the solenoid coil is not energized), the difference in pressure disappears. Then, the pressure applied to the left side of the piston becomes the same as the pressure applied to the right side of the piston. Thus, the spring elongates and eliminates the tilt of the lug plate. As a result, there is a small piston stroke and the discharge capacity decreases.

Y109000C01
1.615,0.156 2.771,0.156 2.771,0.156 3.167,1 false 4.198,2.219 4.438,2.219 4.438,2.219 4.573,2.083 false 1.604,1.083 2.229,1.083 2.229,1.083 2.448,1.438 false 1.427,0.052 1.708,0.281 0.281,0.229 10 *1 1.813,2.479 2.094,2.708 0.281,0.229 10 *a 3.927,3.594 4.167,3.771 0.24,0.177 10 *b 1.417,0.99 1.698,1.219 0.281,0.229 10 *2 4.021,2.125 4.302,2.354 0.281,0.229 10 *4 4.927,2.729 5.208,2.958 0.281,0.229 10 *5 4.927,0.188 5.208,0.417 0.281,0.229 10 *6 3.646,1.542 3.927,1.771 0.281,0.229 10 *3 3.594,3.042 3.875,3.271 0.281,0.229 10 *3
*1 Suction Passage *2 Crank Chamber
*3 Piston *4 Discharge Passage
*5 Solenoid Control Valve *6 Air Conditioning Amplifier Assembly
*a Crank Chamber Pressure + Spring Force *b Piston Stroke: Small