Home › Engine / Hybrid System › 8NR-FTS (ENGINE CONTROL) › SFI SYSTEM › 2016.10–2018.05
NM32H0E _51 Engine / Hybrid System _060396 8NR-FTS ENGINE CONTROL _0296167 SFI SYSTEM DE DETAILS F

8NR-FTS ENGINE CONTROL  SFI SYSTEM  DETAILS  AIR FUEL RATIO SENSOR  


CONSTRUCTION


a.

A planar type air fuel ratio sensor is used.


b.

The planar type air fuel ratio sensor uses alumina, which excels in heat conductivity and electrical insulation, to integrate a sensor element with a heater, thus improving the warm-up performance of the sensor.

W125929C03
3.865,1.552 4.031,1.552 4.031,1.552 4.219,1.792 true 4.573,2.427 5.167,2.427 true 3.885,2.156 4.302,2.156 true 4.552,2.01 5.177,2.01 true 4.448,2.167 5.188,2.167 true 4.354,2.615 4.719,2.688 4.719,2.688 4.938,2.688 true 3.885,1.219 4.146,1.219 4.146,1.219 4.406,2.01 true 3.698,1.469 3.896,1.646 0.198,0.177 10 false *a 3.698,2.063 3.896,2.24 0.198,0.177 10 false *b 5.219,1.927 5.458,2.115 0.24,0.188 10 false *c 5.229,2.094 5.427,2.271 0.198,0.177 10 false *d 4.979,2.583 5.177,2.771 0.198,0.188 10 false *e 5.208,2.354 5.406,2.531 0.198,0.177 10 false *a 3.698,1.135 3.896,1.313 0.198,0.177 10 false *b
*a Alumina *b Platinum Electrode
*c Heater *d Atmosphere
*e Sensor Element (Zirconia) - -



c.

As illustrated below, a conventional oxygen sensor is characterized by a sudden change in its output voltage at the threshold of the stoichiometric air fuel ratio (14.7:1). In contrast, the air fuel ratio sensor data is approximately proportionate to the existing air fuel ratio. The air fuel ratio sensor converts the oxygen density into a voltage signal and sends it to the ECM. As a result, the detection precision of the air fuel ratio has been improved. Air fuel ratio sensor data can be viewed using the Global TechStream (GTS).

W134935E02
3.083,1.167 2,0.167 2,0.167 1.833,0.167 false 4.167,1.5 4.5,0.25 4.5,0.25 4.667,0.25 false 0.792,0.083 1.875,0.333 1.083,0.25 10 false Oxygen Sensor 1.875,0.5 2.333,0.698 0.458,0.198 10 false (V) 5.208,0.469 5.667,0.667 0.458,0.198 10 false (V) 4.75,0.135 6.385,0.333 1.635,0.198 10 false Air Fuel Ratio Sensor 5.5,0.75 5.656,0.948 0.156,0.198 10 false 1 5.333,1.417 6.323,1.781 0.99,0.365 10 false Oxygen Sensor Output 5.458,3.219 5.917,3.417 0.458,0.198 10 false 0.1 2.167,3.667 2.969,3.885 0.802,0.219 10 false 11 (Rich) 3.333,3.719 3.948,3.917 0.615,0.198 10 false 14.7 5.042,3.635 6.417,3.833 1.375,0.198 10 false 19 (Lean) 3.25,3.885 5.396,4.083 2.146,0.198 10 false Air Fuel Ratio 0.302,4.302 5.5,4.583 5.198,0.281 10 false *: This value is calculated internally in the ECM and is not an ECM terminal voltage. 1.583,3.25 2.042,3.448 0.458,0.198 10 false 2.2 1.583,0.75 2.042,0.948 0.458,0.198 10 false 4.2 0.625,1.25 1.979,2.677 1.354,1.427 10 false Air Fuel Ratio Sensor Output* (Data Displayed on Global TechStream (GTS))