Home › Power Source / Network › 8NR-FTS (BATTERY / CHARGING) › CHARGING SYSTEM
NM32H0E _57 Power Source / Network _060418 8NR-FTS BATTERY / CHARGING _0296361 CHARGING SYSTEM DE DETAILS F

8NR-FTS BATTERY / CHARGING  CHARGING SYSTEM  DETAILS  GENERATOR  


CONSTRUCTION


a.

Stator Coil

i.

The joined segment method is used for the stator coil. In this method, segment conductors are inserted and welded together to form the stator. This enables a smaller body, yet higher output, and higher efficiency. By providing a mesh ventilation gap between the coil ends, the coil end inner circumference surfaces that receive the cool wind are smoothened to allow wind to flow smoothly, improving cooling performance and reducing the sound of the wind.

Y130109C02
3.49,1.781 3.635,1.594 3.635,1.594 3.792,1.594 true 4.938,0.479 5.115,0.479 5.115,0.479 5.24,0.979 true 5.885,0.844 6.042,0.448 6.042,0.448 6.25,0.448 false 4.396,1.615 4.531,1.615 4.531,1.615 4.708,1.823 true 1.229,2.302 1.542,2.458 0.313,0.156 10 false *1 3.844,1.531 4.156,1.688 0.313,0.156 10 false *2 4.75,0.417 5.063,0.573 0.313,0.156 10 false *3 2.917,0.198 3.229,0.354 0.313,0.156 10 false *a 3.979,1.167 4.292,1.323 0.313,0.156 10 false *b 6.313,0.375 6.625,0.531 0.313,0.156 10 false *c 3.156,2.021 3.469,2.177 0.313,0.156 10 false *d 4.208,1.552 4.521,1.708 0.313,0.156 10 false *2
*1 Stator *2 Segment
*3 Stator Core - -
*a Twisting *b Joint
*c Ventilation Gap *d Joined Segment Method




b.

Generator Pulley

i.

A clutch is set to the generator pulley.


ii.

Operation of the clutch cancels generator pulley inertia and helps to prevent slipping of the fan and generator V belt. This realizes a low tension fan and generator V belt that achieves reduced friction.

Generator Pulley Cross Section (cSC0 Type Generator)
W134962C01
4.063,0.438 4.333,0.229 4.333,0.229 4.5,0.229 true 4.188,1 4.458,0.792 4.458,0.792 4.625,0.792 true 3.469,0.823 2.781,0.25 2.781,0.25 2.615,0.25 true 2.417,0.156 2.729,0.313 0.313,0.156 10 false *1 4.563,0.135 4.875,0.292 0.313,0.156 10 false *2 4.667,0.698 4.979,0.854 0.313,0.156 10 false *3
*1 Clutch *2 Outer Wheel
*3 Inner Wheel - -


Generator Pulley Cross Section (NRG12+ Type Generator)
W134963C01
4.094,0.531 4.396,0.25 4.396,0.25 4.563,0.25 true 3.135,0.854 2.604,0.406 2.604,0.406 2.438,0.406 true 3.063,1.771 2.385,1.396 2.385,1.396 2.219,1.396 true 3.521,2.031 3.979,2.573 3.979,2.573 4.146,2.573 true 2.25,0.313 2.563,0.469 0.313,0.156 10 false *1 4.625,0.156 4.938,0.313 0.313,0.156 10 false *2 4.188,2.479 4.5,2.635 0.313,0.156 10 false *3 2,1.302 2.313,1.458 0.313,0.156 10 false *4
*1 Coil Spring *2 Pulley
*3 Clutch *4 Shaft





OPERATION


a.

Stator Coil for cSC0 Type Generator

i.

A dual winding system is used. This system consists of 2 sets of three-phase windings whose phase are staggered 30°. This system results in the reduction of both electrical noise (ripple and spike), and magnetic noise (a hum that is heard as generator load is increased). This system significantly suppresses noise at the source (generator). Because the waves that the respective windings generate have opposite polarities, magnetic noise is reduced. The magnetic noise is significantly reduced, but the electrical power generated does not cancel itself out, due to the use of separate rectifiers. The opposite polarities that are generated can be seen below.

W134774E01
1.625,0.177 1.917,0.375 0.292,0.198 10 false 30° 1.385,1.063 1.531,1.24 0.146,0.177 10 false B 2.219,1.073 2.365,1.25 0.146,0.177 10 false A 4.781,1.083 4.927,1.26 0.146,0.177 10 false C 3.031,2 3.177,2.177 0.146,0.177 10 false B 3.031,2.969 3.177,3.146 0.146,0.177 10 false A 0.802,3.208 1.76,3.427 0.958,0.219 10 false Staggered 30° 1.396,3.438 2.385,3.677 0.99,0.24 10 false Dual Windings 6.615,2.948 6.76,3.125 0.146,0.177 10 false C 4.729,3.438 5.802,3.677 1.073,0.24 10 false Single Windings




SPECIFICATION


Item Specification
Generator Type cSC0 NRG12+
Rated Voltage (V) 12 12
Output Rated (A) 100 115
Initial Output Starting Speed (rpm) Max. 1300 Max. 1400