CONSTRUCTION
The basic construction of the air fuel ratio sensor (bank 1, sensor 1) and No. 2 air fuel ratio sensor (bank 1, sensor 2)* is the same. However, they are divided into the cup type and the planar type, in accordance with the different types of heater construction that are used.
*: Models with GPF
The planar type air fuel ratio sensor (bank 1, sensor 1) uses alumina, which excels in heat conductivity and insulation, to integrate a sensor element with the heater, thus achieving the excellent warm-up performance of the sensor.
| *a | Alumina | *b | Platinum Electrode |
| *c | Heater | *d | Atmosphere |
| *e | Sensor Element (Zirconia) | - | - |
The cup type No. 2 air fuel ratio sensor (bank 1, sensor 2) contains a sensor element that surrounds the heater. (Models with GPF)
| *a | Heater | *b | Platinum Electrode |
| *c | Sensor Element (Zirconia) | *d | Atmosphere |