CONSTRUCTION
Except Models for Europe and Destination Package for Taiwan
The cup type oxygen sensor (bank 1, sensor 2) contains a sensor element that surrounds a heater.
The oxygen sensor (bank 1, sensor 2) is located behind the Three-Way Catalytic converter (TWC). The output voltage of the oxygen sensor changes in accordance with the oxygen concentration in the exhaust gas. The ECM uses this output voltage to determine whether the present air fuel ratio is richer or leaner than the stoichiometric air fuel ratio.
| *a | Heater | *b | Atmosphere |
| *c | Platinum Electrode | *d | Sensor Element (Zirconia) |