86750A
1.INSPECT MAYDAY SWITCH ASSEMBLY
| *a | Component without harness connected
(Mayday Switch Assembly) |
| *b | SOS Switch |
| *c | Green Indicator |
| *d | Red Indicator |
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 8 (SIG1) - 1 (GND) | Mayday switch is pushed | 78 to 86 Ω |
| 8 (SIG1) - 1 (GND) | Mayday switch is not pushed | 392 to 432 Ω |
If the resistance is not as specified, replace the mayday switch assembly.
Check the switch illumination.
Apply battery voltage to the mayday switch assembly and check that the illumination comes on.
| Battery Connection | Specified Condition |
|---|---|
| Battery positive (+) → 5 (SLED)
Battery negative (-) → 1 (GND) |
SOS switch comes on |
If the resistance is not as specified, replace the mayday switch assembly.
Check the indicator illumination.
Apply battery voltage to the mayday switch assembly and check that the illumination comes on.
| Battery Connection | Specified Condition |
|---|---|
| Battery positive (+) → 7 (IND1)
Battery negative (-) → 1 (GND) |
Red indicator comes on |
| Battery positive (+) → 3 (IND2)
Battery negative (-) → 1 (GND) |
Green indicator comes on |
If the resistance is not as specified, replace the mayday switch assembly.