RM32H0E
_V1
General
_059376
SPECIFICATIONS
_0295136
3ZR-FAE COOLING
F
SPECIFICATIONS 3ZR-FAE COOLING SERVICE DATA
COOLANT
| Capacity
|
Classification
|
| 5.7 liters (6.1 US qts, 5.1 Imp. qts)
|
Use only "TOYOTA Super Long Life Coolant", or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, and non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of low phosphates and organic acids).
|
THERMOSTAT
| Condition
|
Specified Condition
|
| Standard valve opening temperature
|
78 to 82°C (172 to 180°F)
|
| Standard valve lift
|
for Type A
|
10 mm (0.394 in.) or more at 93°C (199°F)
|
| for Type B
|
10 mm (0.394 in.) to 14 mm (0.551 in.) at 95°C (203°F)
|
COOLING FAN MOTOR
| Item
|
Condition
|
Specified Condition
|
| Cooling fan motor
|
Battery voltage applied at 20°C (68°F)
|
7.4 to 10.9 A
|
COOLING FAN ECU
| Item
|
Condition
|
Specified Condition
|
| Cooling fan motor
|
Battery voltage applied at 20°C (68°F)
|
7.4 to 10.9 A
|
RADIATOR
| Item
|
Condition
|
Specified Condition
|
| Radiator cap
|
Standard value (for brand-new radiator cap sub-assembly)
|
94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.5 to 17 psi)
|
| Minimum standard value (for radiator cap sub-assembly)
|
79 kPa (0.8 kgf/cm2, 11.4 psi)
|
COOLING FAN NO. 1 RELAY
| Tester Connection
|
Condition
|
Specified Condition
|
| 3 - 5
|
Battery voltage not applied between terminals 1 and 2
|
10 kΩ or higher
|
| Battery voltage applied between terminals 1 and 2
|
Below 1 Ω
|