Home › Engine / Hybrid System › 3ZR-FAE (EMISSION CONTROL) › CANISTER
RM32H0E _51 Engine / Hybrid System _060194 3ZR-FAE EMISSION CONTROL _0295175 CANISTER G

3ZR-FAE EMISSION CONTROL  CANISTER  INSPECTION  


PROCEDURE

Hide 1.CHECK CANISTER (FUEL SUCTION TUBE WITH PUMP AND GAUGE ASSEMBLY)

a.

Visually check the canister (fuel suction tube with pump and gauge assembly).

i.

Visually check the canister (fuel suction tube with pump and gauge assembly) for cracks or damage.

If cracks or damage are found, replace the canister (fuel suction tube with pump and gauge assembly).



b.

Inspect the ventilation of the canister (fuel suction tube with pump and gauge assembly).

i.
A379119C01
0.906,0.313 1.167,0.313 1.167,0.313 1.354,0.698 false 1.833,1.208 1.771,1.51 1.771,1.51 1.604,1.51 true 1.417,1.417 1.615,1.625 0.198,0.208 10 true *a 0.698,0.229 1.01,0.469 0.313,0.24 10 false *b 2.542,1.792 2.844,2.042 0.302,0.25 10 false *c
*a Port (A)
*b Port (B)
*c Air


Apply compressed air to the port (A) and check that the air flows out from the port (B).

OK:

The air flows from the port (B).



ii.
A379120C01
1.292,0.156 1.49,0.156 1.49,0.156 1.688,0.479 false 2.271,0.969 2.854,0.969 true 2.906,0.875 3.167,1.063 0.26,0.188 10 false *a 1.052,0.083 1.375,0.302 0.323,0.219 10 false *b 2.542,0.146 2.885,0.427 0.344,0.281 10 false *c
*a Port (A)
*b Port (B)
*c Air


Close the port (A), apply compressed air to the port (B).

OK:

Air does not flow at first. By gradually increasing the pressure, air flows when the pressure in the port reaches a certain level.



iii.
A379121C01
2.302,2.302 2.76,2.302 true 1.521,0.26 1.979,0.26 false 1.427,1.417 1.573,1.417 1.573,1.417 1.646,1.781 false 2.813,2.208 3.104,2.438 0.292,0.229 10 false *a 1.208,1.333 1.427,1.51 0.219,0.177 10 false *b 2.031,0.167 2.365,0.417 0.333,0.25 10 false *c
*a Port (A)
*b Port (B)
*c Vacuum Pump


Using a vacuum pump, apply vacuum to the port (B) with the port (A) closed.

OK:

The vacuum is maintained at first. By gradually increasing the vacuum, air flows and the vacuum decreases after the vacuum reaches a certain level.