HEATING / AIR CONDITIONING  AIR CONDITIONING PRESSURE SENSOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 88719A 1.INSPECT AIR CONDITIONER PRESSURE SENSOR (for DENSO Made)

a.

Check the wire harness.

i.

Disconnect the A22 air conditioner pressure sensor connector.


ii.

Disconnect the F71 air conditioning amplifier assembly connector.


iii.
I113066C02
1.458,0.229 1.948,0.479 0.49,0.25 1.479,1.667 1.969,1.917 0.49,0.25 2.563,2.479 2.917,2.917 true 1.573,2.823 1.24,3.26 true 0.948,2.479 0.5,2.917 true 1.531,0.979 1.167,1.417 true 1.667,1 1.667,1.417 true 1.833,1 2.167,1.417 true 0.625,0.396 0.938,0.552 0.313,0.156 10 false *a 0.25,1.802 0.563,1.958 0.313,0.156 10 false *b 1.583,0.281 1.896,0.438 0.313,0.156 10 false A22 1.604,1.729 1.917,1.885 0.313,0.156 10 false F71 1.125,1.427 1.375,1.583 0.25,0.156 10 false - 1.594,1.448 1.844,1.604 0.25,0.156 10 false PR 2.146,1.427 2.427,1.604 0.281,0.177 10 false + 0.146,2.844 0.563,3 0.417,0.156 10 false SG-2 0.948,3.177 1.365,3.333 0.417,0.156 10 false PRE 2.979,2.833 3.396,2.99 0.417,0.156 10 false S5-3
*a Component without harness connected
(Air Conditioner Pressure Sensor)
*b Component without harness connected
(Air Conditioning Amplifier Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A22-1 (-) - F71-2 (SG-2) Always Below 1 Ω
A22-2 (PR) - F71-24 (PRE) Always Below 1 Ω
A22-3 (+) - F71-6 (S5-3) Always Below 1 Ω
A22-1 (-) or F71-2 (SG-2) - Body ground Always 10 kΩ or higher
A22-2 (PR) or F71-24 (PRE) - Body ground Always 10 kΩ or higher
A22-2 (PR) or F71-24 (PRE) - Body ground Always 10 kΩ or higher


If the resistance is not as specified, repair the wire harness.


iv.

Reconnect the F71 air conditioning amplifier assembly connector.


v.

Ignition switch ON.


vi.
E202734C60
1.385,0.333 1.969,0.583 0.583,0.25 1.906,1.542 2.438,1.958 true 2.479,1.906 2.573,2.083 0.094,0.177 10 false + 0.146,0.094 0.531,0.417 0.385,0.323 10 false *a 1.552,0.375 2.01,0.573 0.458,0.198 10 false A22
*a Component without harness connected
(Air Conditioner Pressure Sensor)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A22-3 (+) - Body ground Ignition switch ON 4.75 to 5.25 V


If the voltage is not as specified, repair the wire harness or replace air conditioning amplifier assembly.



b.

Check the air conditioner pressure sensor.

i.

Connect the connector to the air conditioner pressure sensor.


ii.

Install a manifold gauge set.


iii.

Turn the A/C switch on.


iv.
E328993C20
0.542,0.26 0.958,0.5 0.417,0.24 0.521,1.875 0.844,1.333 false 1.604,1.896 1.208,1.115 false 0.094,0.094 0.406,0.25 0.313,0.156 10 false *a 0.635,0.292 0.948,0.521 0.313,0.229 10 false F71 0.385,1.948 0.698,2.104 0.313,0.156 10 false PRE 1.5,1.927 2,2.104 0.5,0.177 10 false SG-2
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


Measure the voltage according to the value(s) in the table below.

HINT:

Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.


Standard Voltage:
Tester Connection Condition Specified Condition
F71-24 (PRE) -F71-2 (SG-2) Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) 0.74 to 4.61 V


If the voltage is not as specified, replace the air conditioner pressure sensor.



Hide 88719A 2.INSPECT AIR CONDITIONER PRESSURE SENSOR (for VALEO Made)

a.

Check the wire harness.

i.

Disconnect the A52 air conditioner pressure sensor connector.


ii.

Disconnect the F72 air conditioning amplifier assembly connector.


iii.
I113813C01
1.458,0.208 1.958,0.417 0.5,0.208 1.458,1.833 1.958,2.042 0.5,0.208 1.125,1.5 1.542,1.083 true 1.698,1.594 1.698,1.083 true 2.24,1.469 1.854,1.115 true 2.458,3.021 2.073,2.667 true 1.948,3.094 1.948,2.708 true 1.521,3.031 1.854,2.688 true 0.083,0.083 0.396,0.281 0.313,0.198 10 false *a 1.563,0.25 1.958,0.448 0.396,0.198 10 false A52 1.573,1.865 1.969,2.063 0.396,0.198 10 false F72 1.031,1.521 1.344,1.719 0.313,0.198 10 false + 1.625,1.625 1.938,1.823 0.313,0.198 10 false PR 2.313,1.448 2.625,1.646 0.313,0.198 10 false - 1.26,3.073 1.688,3.281 0.427,0.208 10 false SG-2 1.823,3.135 2.25,3.344 0.427,0.208 10 false PRE 2.396,3.063 2.823,3.271 0.427,0.208 10 false S5-3
*a Component without harness connected
(Air Conditioner Pressure Sensor)
*b Component without harness connected
(Air Conditioning Amplifier Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A52-3 (-) - F72-32 (SG-2) Always Below 1 Ω
A52-2 (PR) - F72-33 (PRE) Always Below 1 Ω
A52-1 (+) - F72-34 (S5-3) Always Below 1 Ω
A52-1 (+) - Body ground Always 10 kΩ or higher
A52-2 (PR) - Body ground Always 10 kΩ or higher
A52-3 (SG-2) - Body ground Always 10 kΩ or higher


If the resistance is not as specified, repair the wire harness.


iv.

Reconnect the F72 air conditioning amplifier assembly connector.


v.

Ignition switch ON.


vi.
I113815C01
1.458,0.167 1.938,0.417 0.479,0.25 1.104,1.563 1.521,1.146 true 0.115,0.094 0.427,0.292 0.313,0.198 10 false *a 1.552,0.229 1.917,0.417 0.365,0.188 10 false A52 0.99,1.604 1.302,1.802 0.313,0.198 10 false +
*a Component without harness connected
(Air Conditioner Pressure Sensor)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A52-1 (+) - Body ground Ignition switch ON 4.75 to 5.25 V


If the voltage is not as specified, repair the wire harness or replace air conditioning amplifier assembly.



b.

Check the air conditioner pressure sensor.

i.

Install a manifold gauge set.


ii.

Connect the A52 air conditioner pressure sensor connector.


iii.

Start the engine.


iv.

Measure the voltage according to the value(s) in the table below.

I113814C01
1.5,0.25 2.167,0.5 0.667,0.25 1.281,2.042 1.542,1.573 true 1.906,2.01 1.677,1.583 true 0.177,0.083 0.49,0.281 0.313,0.198 10 false *a 1.708,0.292 2.021,0.49 0.313,0.198 10 false F72 1.146,2.063 1.552,2.25 0.406,0.188 10 false PRE 1.781,2.042 2.333,2.24 0.552,0.198 10 false SG-2
*a Component with harness connected
(Air Conditioning Amplifier Assembly)
- -


Standard Voltage:
Tester Connection Condition Specified Condition
F72-33 (PRE) - F72-32 (SG-2) Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) 0.63 to 4.72 V


If the voltage is not as specified, replace the air conditioner pressure sensor.