Home › Power Source / Network › 3ZR-FAE (BATTERY / CHARGING) › CHARGING SYSTEM
RM32H0E _57 Power Source / Network _060210 3ZR-FAE BATTERY / CHARGING _0295689 CHARGING SYSTEM U

3ZR-FAE BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECM  


CHECK ECM


A381896E06
5.802,0.427 6.167,0.677 0.365,0.25 2.552,0.417 2.938,0.667 0.385,0.25 2.615,0.448 3.042,0.708 0.427,0.26 10 false C63 5.865,0.458 6.26,0.719 0.396,0.26 10 false A38

HINT:

The standard normal voltage between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
C63-59 (E1) - Body ground W-B - Body ground Ground Always Below 1 Ω
A38-1 (BATT) - C63-59 (E1) R - W-B Battery
(for measuring battery voltage and for ECM memory)
Always 11 to 14 V
C63-61 (LIN) - Body ground B - Body ground LIN communication line Ignition switch off
(while LIN communication is stopped)
10 kΩ or higher