Home › Power Source / Network › 3ZR-FAE (BATTERY / CHARGING) › CHARGING SYSTEM
RM32H0E _57 Power Source / Network _060210 3ZR-FAE BATTERY / CHARGING _0295689 CHARGING SYSTEM C

3ZR-FAE BATTERY / CHARGING  CHARGING SYSTEM  P161A  Lost Communication with Alternator  


DESCRIPTION

The ECM and generator assembly detect reception errors respectively.

The generator assembly reception error detected by the generator assembly is sent to the ECM via LIN communication. If an error occurs in the ECM or generator assembly, the ECM determines there is a LIN communication error and stores this DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area
P161A Lost Communication with Alternator Generator assembly or ECM communication stop for about 17 minutes or more with the ignition switch ON.
(1 trip detection logic)
·

Wire harness and connector

·

Generator assembly

·

ECM



WIRING DIAGRAM

A340530E41
1.51,3.167 5.177,3.365 3.667,0.198 10 false : LIN Communication Line 5.073,2.521 6.302,2.719 1.229,0.198 10 false C63 1.594,2.177 2.052,2.375 0.458,0.198 10 false C37 1.594,2.344 3.167,2.781 1.573,0.438 10 false Generator Assembly 4.885,1.708 5.344,1.906 0.458,0.198 10 false LIN 3.083,1.531 3.24,1.729 0.156,0.198 10 false 2 4.625,1.531 4.938,1.729 0.313,0.198 10 false 61 2.792,1.698 3.25,1.896 0.458,0.198 10 false LIN 5.073,2.688 6.302,2.885 1.229,0.198 10 false ECM

PROCEDURE

1.CHECK CHARGING SYSTEM

Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (ECM - GENERATOR ASSEMBLY)

NG

REPAIR OR REPLACE CHARGING SYSTEM

2.CHECK HARNESS AND CONNECTOR (ECM - GENERATOR ASSEMBLY)
a.

Disconnect the C63 ECM connector.


b.

Disconnect the C37 generator assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C63-61 (LIN) - C37-2 (LIN) Always Below 1 Ω
C63-61 (LIN), C37-2 (LIN) - body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR