Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System with Side-mounted Air Conditioner Pressure Sensor)
RM32H0E _58 Vehicle Interior _059841 HEATING / AIR CONDITIONING _0298708 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System with Side-mounted Air Conditioner Pressure Sensor) D

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System with Side-mounted Air Conditioner Pressure Sensor)  SYSTEM DESCRIPTION  


GENERAL


The air conditioning system has the following controls.

Control Outline
Neural Network Control This control is capable of performing complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input/output relationship similar to that of a human brain.
Outlet Air Temperature Control Based on the temperature set by the temperature control dial, neural network control calculates outlet air temperature based on input signals from various sensors.
Left and Right Independent Control The temperature settings for the driver and front passenger are controlled independently in order to provide separate vehicle interior temperatures for the right and left sides of the vehicle. Thus, air conditioning that accommodates the occupants' preferences has been realized.
Blower Control Controls the blower motor in accordance with the airflow volume that has been calculated by neural network control based on input signals from various sensors.
Air Outlet Control Automatically switches the air outlets in accordance with the outlet mode that has been calculated by neural network control.
In accordance with the engine coolant temperature, ambient air temperature, amount of sunlight, required blower, outlet temperature and vehicle speed conditions, this control automatically switches the blower outlet to foot/defroster mode to prevent the windows from becoming fogged up when the ambient air temperature is low.
Air Inlet Control Automatically controls the air inlet control damper to help achieve the calculated outlet air temperature that is required.
Drives the air inlet control servo motor according to the operation of the air inlet control switch and moves the dampers to the fresh or recirculation position.
Variable Capacity Compressor Control Controls the compressor with pulley assembly to turn it on or off and adjust the discharge capacity based on the signals from various sensors.
Defroster Control Defroster control logic is used to improve defroster performance.
ECO Mode Control When the air conditioning control assembly (ECO mode switch) is turned on, the air conditioning amplifier assembly limits the air conditioning system performance.
Parking Fresh Control By automatically switching to fresh air mode when the vehicle is parked. Ventilation of the parked vehicle is facilitated and outside air is introduced into the air conditioner unit assembly.
Diagnosis A Diagnostic Trouble Code (DTC) is stored in memory when the air conditioning amplifier assembly detects a problem with the air conditioning system.


NEURAL NETWORK CONTROL


·

In previous automatic air conditioning systems, the air conditioning amplifier assembly determined the required outlet air temperature and blower air volume in accordance with the calculation formula that has been obtained based on information received from the sensors.

However, because the senses of a person are rather complex, a given temperature is sensed differently, depending on the environment in which the person is situated. For example, a given amount of solar radiation can feel comfortably warm in a cold climate, or extremely uncomfortable in a hot climate. Therefore, as a technique for effecting a higher level of control, a neural network has been adopted in the automatic air conditioning system. With this technique, the data that has been collected under varying environmental conditions is stored in the air conditioning amplifier assembly. The air conditioning amplifier assembly can then effect control to provide enhanced air conditioning comfort.

·

The neural network control consists of neurons in the input layer, intermediate layer and output layer. The input layer neurons process the input data of the outside temperature, the amount of sunlight and the room temperature based on the outputs of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of these is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume and outlet mode control volume. Accordingly, the air conditioning amplifier assembly controls the servo motors and blower motor in accordance with the control volumes that have been calculated by the neural network control.


E266253E02
3.417,2.906 3.958,3.198 0.542,0.292 10 false Control 3,0.073 4.156,0.375 1.156,0.302 10 false Intermediate Layer 2.073,0.344 2.813,0.552 0.74,0.208 10 false Input Layer 4.458,0.354 5.417,0.594 0.958,0.24 10 false Output Layer 1.396,0.75 2.823,0.979 1.427,0.229 10 false Ambient Temperature 4.531,0.75 6.271,0.979 1.74,0.229 10 false Target Output Temperature 1.531,1.344 2.719,1.583 1.188,0.24 10 false Amount of Sunlight 1.542,1.948 2.719,2.188 1.177,0.24 10 false Cabin Temperature 0.333,4.333 1.385,4.635 1.052,0.302 10 false Input Processing 0.396,5.354 1.188,5.792 0.792,0.438 10 false Temperature Setting 0.406,6.604 1.219,6.906 0.813,0.302 10 false Sensor Input 0.406,7.771 1.219,8.073 0.813,0.302 10 false Switch Input 2.688,7.771 3.5,8.073 0.813,0.302 10 false Compressor 5.969,7.771 6.781,8.073 0.813,0.302 10 false Compressor 2.781,7.26 3.594,7.563 0.813,0.302 10 false Inlet Mode 2.729,6.625 3.542,6.927 0.813,0.302 10 false Outlet Mode 2.667,5.719 3.51,6.083 0.844,0.365 10 false Target Airflow Volume 2.49,4.813 3.677,5.24 1.188,0.427 10 false Amount of Sunlight Correction 2.646,3.948 3.542,4.406 0.896,0.458 10 false Target Output Temperature 2.594,3.417 3.552,3.802 0.958,0.385 10 false Neural Network 4.344,3.563 5.135,4.094 0.792,0.531 10 false Temperature Control Correction 4.208,5.167 5.26,5.958 1.052,0.792 10 false Various Types of Airflow Volume Correction 4.219,6.354 5.26,6.823 1.042,0.469 10 false Various Types of Mode Correction 4.208,7.146 5.271,7.521 1.063,0.375 10 false Various Types of Correction 5.958,6.927 6.823,7.313 0.865,0.385 10 false Recirculation Damper Servo 5.958,6.063 6.823,6.448 0.865,0.385 10 false Mode Damper Servo 5.958,5.552 6.823,5.938 0.865,0.385 10 false Blower Motor 5.875,4 6.875,4.406 1,0.406 10 false Air Mix Damper Servo 5.74,2.906 6.896,3.292 1.156,0.385 10 false Output Processing 0.615,8.375 2.823,8.646 2.208,0.271 10 false : Neural Network Operation Range


MODE POSITION AND DAMPER OPERATION


Mode Position and Damper Operation

A395231C01
1.604,1.542 1.99,1.094 true 0.875,1.552 0.5,1.115 true 3.906,1.26 3.74,0.958 true 4.365,1.167 4.198,0.896 true 3.646,1.99 3.438,1.885 true 5.792,2.771 5.625,2.469 true 5.198,2.729 4.865,2.271 true 4.823,2.75 4.698,2.417 true 6.688,1.906 6.458,1.583 true 6.74,1.552 6.385,1.323 true 5.677,1.479 6.031,1.313 true 5.188,1.417 5.042,1.781 true 0.333,1.01 0.646,1.167 0.313,0.156 10 false *1 2.083,1.01 2.396,1.167 0.313,0.156 10 false *2 3.375,0.167 3.688,0.323 0.313,0.156 10 false *3 4.74,0.042 5.052,0.198 0.313,0.156 10 false *4 6.125,0.146 6.438,0.302 0.313,0.156 10 false *5 6.792,1.573 7.104,1.729 0.313,0.156 10 false *6 5.479,1.469 5.792,1.625 0.313,0.156 10 false *7 6.708,1.969 7.021,2.125 0.313,0.156 10 false *8 5.76,2.823 6.073,2.979 0.313,0.156 10 false *9 5.156,2.76 5.625,2.917 0.469,0.156 10 false *10 4.74,2.771 5.208,2.927 0.469,0.156 10 false *11 5.208,1.26 5.677,1.417 0.469,0.156 10 false *12 3.969,0.76 4.438,0.917 0.469,0.156 10 false *13 1.917,2.938 2.385,3.094 0.469,0.156 10 false *14 4.156,2.958 4.625,3.115 0.469,0.156 10 false *15 1.406,3.833 1.875,3.99 0.469,0.156 10 false *16 2.198,3.969 2.667,4.125 0.469,0.156 10 false *17 5.063,3.833 5.531,3.99 0.469,0.156 10 false *18 0.292,0.26 0.604,0.417 0.313,0.156 10 false *a 4.333,1.646 4.646,1.802 0.313,0.156 10 false *b 5.365,0.969 5.677,1.125 0.313,0.156 10 false *c 5.698,0.667 5.969,0.854 0.271,0.188 10 false *d 3.51,0.823 3.979,0.979 0.469,0.156 10 false *13 3.188,1.771 3.656,1.927 0.469,0.156 10 false *13 3.792,3.958 4.26,4.115 0.469,0.156 10 false *17 6.469,0.563 6.74,0.75 0.271,0.188 10 false *d 6.896,0.979 7.104,1.177 0.208,0.198 10 false *c
*1 Driver Side Air Mix Control Damper *2 Front Passenger Side Air Mix Control Damper
*3 Driver Side Defroster *4 Front Defroster
*5 Front Passenger Side Defroster *6 Air Inlet Control Damper (Lower Side)
*7 Air Inlet Control Damper (Upper Side) *8 Clean Air Filter
*9 Blower with Fan Motor Sub-assembly *10 No. 1 Cooler Evaporator Sub-assembly
*11 Air Mix Control Damper *12 Heater Radiator Unit Sub-assembly
*13 Mode Switching Damper *14 Driver Side Footwell Register
*15 Front Passenger Side Footwell Register *16 Driver Side Register
*17 Center Register *18 Front Passenger Side Register
*a Illustration Image View from [A] *b [A] View
*c Recirculated Air *d Fresh Air


Functions of Main Dampers
Control Damper Operation Position Damper Position Operation
Air Inlet Control Damper FRESH A1, B1 Allows fresh air to enter.
RECIRCULATION A2, B2 Causes internal air to recirculate.
Air Mix Control Damper Temperature Setting: 16°C (61°F) to 30°C (86°F) C1 - C2 Varies the driver side mixture ratio of the fresh air and the recirculation air in order to regulate the temperature continuously from HI to LO.
D2 - D1 Varies the front passenger side mixture ratio of the fresh air and the recirculation air in order to regulate the temperature continuously from HI to LO.
Air Outlet Control Damper DEF
E264847

F, H, K Defrosts the windshield through the center defroster, side defrosters and side registers.
FOOT/DEF
E264851

F, H, J to K Defrosts the windshield through the center defroster, side defrosters and side registers, while air is also blown out from the front and rear footwell register ducts.
FOOT
E264850

E, (E to F)*, H, J Air blows out of the front and rear footwell register ducts and side registers. In addition, air blows out slightly from the center defroster and side defrosters.
B/L
E264849

E, G to I, J to K Air blows out of the center registers, side registers and front and rear footwell register ducts.
FACE
E264852

E, G, K Air blows out of the center registers and side registers.


AIR OUTLETS AND AIRFLOW VOLUME


The size of each circle ○ indicates the ratio of airflow volume.

a.

Air Outlets and Airflow Volume.

E352294

Mode FACE FOOT DEF
Center Side Front Center Side
A B C D E
FACE
E264852

E264853

E264853

E264858

E264858

E264858

B/L
E264849

E264854

E264854

E264854

E264858

E264858

FOOT
E264850

E264858

E264856

E264854

E264856

E264856

FOOT/DEF
E264851

E264858

E264856

E264854

E264854

E264856

DEF
E264847

E264858

E264854

E264858

E264853

E264854




FRESH AIR INTRODUCTION WHILE PARKING CONTROL


When 60 seconds have elapsed since the ignition switch has been turned off, the air conditioning amplifier assembly uses control logic which automatically changes the air inlet to FRESH mode to purge undesired odors from the air conditioning unit.

This logic will therefore reduce undesired odors upon starting the air conditioning system.

E279972E25
0.177,0.104 1.115,0.313 0.938,0.208 10 false Timing Chart: 0.188,0.927 1.302,1.365 1.115,0.438 10 false When Last Mode RECIRCULATION 2.021,1.438 3.208,1.667 1.188,0.229 10 false RECIRCULATION 2.625,0.885 3.24,1.094 0.615,0.208 10 false FRESH 2.615,2.698 3.271,2.906 0.656,0.208 10 false FRESH 2.021,3.042 3.208,3.271 1.188,0.229 10 false RECIRCULATION 3.26,3.385 4.625,3.615 1.365,0.229 10 false Ignition Switch off 0.198,2.792 1.271,3.219 1.073,0.427 10 false When Last Mode FRESH 5.385,3.385 6.854,3.604 1.469,0.219 10 false Ignition Switch ON 3.917,0.177 4.469,0.375 0.552,0.198 10 false 60 Sec. 4.646,0.167 6.177,0.417 1.531,0.25 10 false Air Mode When Parked


COMPRESSOR WITH PULLEY


a.

General:

i.

The compressor is a continuously variable capacity type in which its capacity can be varied in accordance with the cooling load of the air conditioning system.

Y206776C03
3.594,1.625 3.083,0.667 3.083,0.667 2.917,0.667 true 2.25,0.833 2.417,0.833 2.417,0.833 2.75,1.688 true 1.25,1.167 1.417,1.167 1.417,1.167 2.26,2.427 true 2.083,4.083 2.25,4.083 2.25,4.083 2.875,3.25 true 2.833,4.333 3,4.333 3,4.333 3.469,3.365 true 3.833,4.083 4,4.083 4,4.083 4.25,3.365 true 5.385,2.198 6.167,3.417 6.167,3.417 6.333,3.417 true 4.083,1.667 4.5,0.667 4.5,0.667 4.667,0.667 true 2.719,0.552 3.031,0.708 0.313,0.156 10 false *1 2.052,0.708 2.365,0.865 0.313,0.156 10 false *2 1.073,1.063 1.385,1.219 0.313,0.156 10 false *3 1.896,3.969 2.208,4.125 0.313,0.156 10 false *4 2.646,4.219 2.958,4.375 0.313,0.156 10 false *5 3.635,3.969 3.948,4.125 0.313,0.156 10 false *6 6.375,3.333 6.688,3.49 0.313,0.156 10 false *7 4.708,0.583 5.021,0.74 0.313,0.156 10 false *5
*1 Shoe *2 Crank Chamber
*3 Shaft *4 Lug Plate
*5 Piston *6 Cylinder
*7 Solenoid Control Valve - -




b.

Solenoid Valve Operation:

i.

The crank chamber is connected to the suction passage. A solenoid valve is provided between the suction passage (low pressure) and the discharge passage (high pressure).


ii.

The solenoid valve operates under duty cycle control in accordance with the signals from the air conditioning amplifier assembly.

Y108998C07
2.583,0.333 2.75,0.333 2.75,0.333 3.167,1.167 false 4.167,2.333 4.333,2.333 4.333,2.333 4.573,2.198 true 2.083,1.25 2.25,1.25 2.25,1.25 2.458,1.656 true 2.365,0.229 2.646,0.458 0.281,0.229 10 false *1 1.875,1.146 2.156,1.375 0.281,0.229 10 false *2 4.021,2.229 4.302,2.458 0.281,0.229 10 false *4 4.927,2.917 5.208,3.146 0.281,0.229 10 false *5 4.917,0.344 5.198,0.573 0.281,0.229 10 false *6 3.625,1.74 3.906,1.969 0.281,0.229 10 false *3 3.229,3.198 3.51,3.427 0.281,0.229 10 false *3
*1 Suction Passage *2 Crank Chamber
*3 Piston *4 Discharge Passage
*5 Solenoid Control Valve *6 Air Conditioning Amplifier Assembly



iii.

When the solenoid control valve closes (the solenoid coil is energized), a difference in pressure is created and the pressure in the crank chamber decreases. Then, the pressure applied to the right side of the piston becomes greater than the pressure applied to the left side of the piston. This compresses the spring and tilts the lug plate. As a result, the piston stroke increases and the discharge capacity increases.

Y108999C07
2.5,0.333 2.667,0.333 2.667,0.333 3.167,1 false 4.25,2.167 4.417,2.167 4.417,2.167 4.573,2.042 true 2.083,1.167 2.24,1.167 2.24,1.167 2.458,1.521 true 2.313,0.25 2.594,0.479 0.281,0.229 10 false *1 1.823,2.469 2.104,2.698 0.281,0.229 10 false *a 3.771,3.51 4.052,3.74 0.281,0.229 10 false *b 1.885,1.073 2.167,1.302 0.281,0.229 10 false *2 4.042,2.073 4.323,2.302 0.281,0.229 10 false *4 4.917,2.729 5.198,2.958 0.281,0.229 10 false *5 4.917,0.188 5.198,0.417 0.281,0.229 10 false *6 3.625,1.573 3.906,1.802 0.281,0.229 10 false *3 3.229,3.063 3.51,3.292 0.281,0.229 10 false *3
*1 Suction Passage *2 Crank Chamber
*3 Piston *4 Discharge Passage
*5 Solenoid Control Valve *6 Air Conditioning Amplifier Assembly
*a Crank Chamber Pressure + Spring Force *b Piston Stroke: Large



iv.

When the solenoid control valve opens (the solenoid coil is not energized), the difference in pressure disappears. Then, the pressure applied to the left side of the piston becomes the same as the pressure applied to the right side of the piston. Thus, the spring elongates and eliminates the tilt of the lug plate. As a result, there is a small piston stroke and the discharge capacity decreases.

Y109000C08
2.583,0.167 2.75,0.167 2.75,0.167 3.167,1 false 4.25,2.25 4.417,2.25 4.417,2.25 4.573,2.083 true 2.083,1.083 2.25,1.083 2.25,1.083 2.448,1.438 true 2.385,0.073 2.667,0.302 0.281,0.229 10 false *1 1.813,2.479 2.094,2.708 0.281,0.229 10 false *a 3.927,3.594 4.167,3.771 0.24,0.177 10 false *b 1.875,0.958 2.156,1.188 0.281,0.229 10 false *2 4.052,2.146 4.333,2.375 0.281,0.229 10 false *4 4.927,2.729 5.208,2.958 0.281,0.229 10 false *5 4.927,0.188 5.208,0.417 0.281,0.229 10 false *6 3.646,1.542 3.927,1.771 0.281,0.229 10 false *3 3.594,3.042 3.875,3.271 0.281,0.229 10 false *3
*1 Suction Passage *2 Crank Chamber
*3 Piston *4 Discharge Passage
*5 Solenoid Control Valve *6 Air Conditioning Amplifier Assembly
*a Crank Chamber Pressure + Spring Force *b Piston Stroke: Small





ION GENERATOR SUB-ASSEMBLY (w/ Ion Generator)


a.

The ion generator sub-assembly operates when the blower switch are on.


b.

The ion generator sub-assembly emits "nanoe" ions that are electrically charged and encapsulated with water. The ions are discharged into the cabin through the side register (front passenger side) to provide skin-friendly clean air.*

CAUTION:
E352299

Do not attempt to disassemble or repair the ion generator sub-assembly because it contains high voltage parts.


NOTICE:

Do not insert anything into the side register (front passenger side), attach anything to it, or use sprays around it. Doing so may cause the ion generator sub-assembly to not work properly.


HINT:
·

*: According to the temperature and humidity conditions, fan speed and air outlet mode selected, the ion generator sub-assembly may not operate at full capacity.

·

When the ion generator sub-assembly operates, a small amount of ozone is emitted and may be faintly smelled in some situations. However, this is approximately the same as the amount that already exists in nature, such as in forests, and as such has no effect on the human body.

·

A slight noise may be heard during operation. This does not indicate a malfunction.



E357635C03
1.75,0.917 1,0.167 true 3.781,2 3.271,1.5 true 1.604,2.583 1.271,2.583 false 5.927,1.25 5.677,1 true 6.167,0.979 5.917,0.729 false 5.083,1.135 4.833,0.885 false 0.813,0.063 1.125,0.219 0.313,0.156 10 false *1 1.698,2.479 2.01,2.635 0.313,0.156 10 false *b 5.052,2.083 5.365,2.24 0.313,0.156 10 false *a 6.188,2.083 6.5,2.24 0.313,0.156 10 false *b 4.635,0.771 4.948,0.927 0.313,0.156 10 false *c 5.49,0.896 5.802,1.052 0.313,0.156 10 false *d 3.823,1.906 4.135,2.063 0.313,0.156 10 false *2 5.729,0.625 6.042,0.781 0.313,0.156 10 false *c
*1 Ion Generator Sub-assembly *2 Air Conditioning Control Assembly (nanoe indicator)
*a Common Negative Ion *b "nanoe" Ion
*c H2O *d Electron


HINT:

"nanoe" is a trademark of Panasonic Co., Ltd.




NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR)


The No. 1 cooler thermistor (evaporator temperature sensor) detects the temperature of the cool air immediately after the evaporator in the form of resistance changes, and outputs it to the air conditioning amplifier assembly.


BLOWER MOTOR WITH FAN SUB-ASSEMBLY


The blower motor has a built-in blower controller, and is controlled using duty control performed by the air conditioning amplifier assembly.


BUS CONNECTOR (AIR CONDITIONING HARNESS ASSEMBLY)


a.

Bus connectors are used in the wire harness that connects the servo motors to the air conditioning amplifier assembly.

E361434C01
0.542,1.719 0.854,1.875 0.313,0.156 10 false *a 6.063,1.698 6.375,1.854 0.313,0.156 10 false *b 4.646,0.927 4.958,1.083 0.313,0.156 10 false *c 1.865,2.969 2.177,3.125 0.313,0.156 10 false *d 0.094,0.083 1.563,0.323 1.469,0.24 12 false Example:
*a Bus Connector
(to No. 1 Air Conditioning Radiator Damper Servo Sub-assembly)
*b Bus Connector
(to No. 1 Blower Damper Servo Sub-assembly)
*c to No. 1 Cooler Thermistor (Evaporator Temperature Sensor) *d to Air Conditioning Amplifier Assembly



b.

Each bus connector has a built-in communication/driver IC which communicates with the air conditioning amplifier assembly, actuates the servo motor, and has a position detection function. This enables bus communication for the servo motor wire harness, for a more lightweight construction and a reduced number of wires.

E334763E01
4.354,0.844 4.281,0.406 4.281,0.406 4.135,0.406 false 4.552,0.948 4.677,0.24 4.677,0.24 4.833,0.24 false 0.427,0.583 5.781,0.781 5.354,0.198 10 false Air Conditioning Amplifier Assembly 0.792,1.177 6.146,1.375 5.354,0.198 10 false Communication Circuit 1.323,2.031 1.885,2.292 0.563,0.26 10 false CPU 0.813,3.333 6.167,3.531 5.354,0.198 10 false : LIN Communication Line 6.073,2.135 7.031,2.396 0.958,0.26 10 false Servo Motor 3.177,0.313 4.458,0.521 1.281,0.208 10 false Bus Connector 4.917,0.156 6.844,0.417 1.927,0.26 10 false Communication/Driver IC



SERVO MOTOR


A pulse pattern type servo motor consists of a printed circuit board and a servo motor. The printed circuit board has three contact points, and can transmit two ON-OFF signals to the air conditioning amplifier assembly based on the difference of the pulse phases. The bus connector can detect the damper position and movement direction with these signals.


COOLER (ROOM TEMP. SENSOR) THERMISTOR


The cooler (room temp. sensor) thermistor detects the cabin temperature based on changes in the resistance of its built-in thermistor and sends a signal to the air conditioning amplifier assembly.


THERMISTOR ASSEMBLY


The thermistor assembly detects the outside temperature based on changes in the resistance of its built-in thermistor and sends a signal to the combination meter assembly and via CAN communication, it sends the outside temperature information to air conditioning amplifier assembly.


AUTOMATIC LIGHT CONTROL SENSOR


The automatic light control sensor detects (in the form of changes in the current that flows through the built-in photo diode) the changes in the amount of sunlight and outputs these sunlight strength signals to the air conditioning amplifier assembly.


AIR CONDITIONER PRESSURE SENSOR


The air conditioner pressure sensor detects the refrigerant pressure and outputs it to the air conditioning amplifier assembly in the form of voltage changes.