Home › Brake › BRAKE SYSTEM (OTHER) › VACUUM PUMP (for 8NR-FTS)
RM32H0E _54 Brake _060040 BRAKE SYSTEM (OTHER) _0299736 VACUUM PUMP(for 8NR-FTS) G

BRAKE SYSTEM (OTHER)  VACUUM PUMP(for 8NR-FTS)  INSPECTION  


PROCEDURE

Hide 29331A 1.INSPECT VACUUM PUMP VANE

a.
C169339C03
1.665,1.497 1.824,1.641 0.158,0.144 10 *2 0.864,1.712 1.018,1.854 0.154,0.142 10 *1 2.135,0.256 2.285,0.403 0.15,0.147 10 *1 2.707,0.665 2.707,0.339 2.707,0.339 2.32,0.339 false 1.323,1.371 1.323,1.584 1.323,1.584 1.641,1.584 false 0.529,1.532 0.529,1.8 0.529,1.8 0.841,1.8 false
*1 Vacuum Pump Vane Cap
*2 Vacuum Pump Vane


Check that the vacuum pump vane or vacuum pump vane caps are not damaged or excessively worn out.

HINT:

If the vacuum pump vane or vacuum pump vane caps are damaged or excessively worn out, replace the damaged parts with new ones.



b.
C169340C03
2.354,2.365 2.625,2.625 0.271,0.26 10 false (A) 1.271,2.365 1.531,2.573 0.26,0.208 10 false (A) 0.802,3 1.052,3.208 0.25,0.208 10 false *a 2.531,2.99 2.729,3.208 0.198,0.219 10 false *a
*a 10 mm (0.394 in.)


Using a micrometer, measure length (A) of the vacuum pump vane with the vacuum pump vane caps removed.

Minimum Length (A):

23.8 mm (0.937 in.)


NOTICE:

Measure the length 10 mm (0.394 in.) in from each end of the vacuum pump vane.


HINT:

If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones.



c.
C169342C06
0.948,1.969 0.948,1.719 0.948,1.719 1.406,1.719 false 2.448,2.625 2.448,2.875 false 0.552,2.625 0.552,2.875 false 2.729,1.969 2.958,2.188 0.229,0.219 10 false *a 2.74,2.469 3,2.656 0.26,0.188 10 false *a 1.479,1.656 1.646,1.823 0.167,0.167 10 false *1 2.365,2.938 2.531,3.104 0.167,0.167 10 false *2 0.458,2.927 0.625,3.094 0.167,0.167 10 false *2 1.427,1.979 1.667,2.177 0.24,0.198 10 false (B) 1.427,2.26 1.667,2.458 0.24,0.198 10 false (B)
*1 Vacuum Pump Vane
*2 Vacuum Pump Vane Cap
*a 5 mm (0.197 in.)


Using a vernier caliper, measure length (B) of the vacuum pump vane with the vacuum pump vane caps installed.

Minimum Length (B):

76.0 mm (2.99 in.)


NOTICE:

Measure the length 5 mm (0.197 in.) in from each end of the vacuum pump vane caps.


HINT:

If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones.



Hide 2.INSPECT VACUUM PUMP HOUSING

a.
C326541

Check that the rotor part, coupling, vacuum pump housing and end cover are not damaged or excessively worn out.

HINT:

If the rotor part, coupling, vacuum pump housing or end cover are damaged or excessively worn out, replace the vacuum pump assembly.