Home › Brake › BRAKE SYSTEM (OTHER) › VACUUM PUMP (for 3ZR-FAE)
RM32H0E _54 Brake _060040 BRAKE SYSTEM (OTHER) _0299737 VACUUM PUMP(for 3ZR-FAE) A

BRAKE SYSTEM (OTHER)  VACUUM PUMP(for 3ZR-FAE)  REASSEMBLY  


PROCEDURE

Hide 29331A 1.INSTALL VACUUM PUMP VANE

a.

Apply engine oil to the vacuum pump vane and 2 vacuum pump vane caps.


b.
C169339C12
1.802,1.281 1.802,1.469 false 2.75,1.042 2.75,1.24 false 0.656,1.51 0.656,1.708 false 1.74,1.5 2.24,1.729 0.5,0.229 10 false *2 2.688,1.271 3.156,1.583 0.469,0.313 10 false *1 0.594,1.719 1.25,1.969 0.656,0.25 10 false *1
*1 Vacuum Pump Vane Cap
*2 Vacuum Pump Vane


Install the vacuum pump vane caps to the vacuum pump vane.

NOTICE:

When reusing the vacuum pump vane and vacuum pump vane caps, install them in the same position as when they were removed.



c.
C142620C01
1.229,0.833 1.385,1.031 0.156,0.198 10 .
V100135

Engine Oil


Apply engine oil to the vacuum pump vane with vacuum pump vane caps and install it to the vacuum pump housing.

NOTICE:

When reusing the vacuum pump vane and vacuum pump vane caps, install them in the same position and orientation as when they were removed.



Hide 29314A 2.INSTALL END COVER

a.
C169343C01
0.844,3.438 0.844,4 true 0.781,4.031 1.24,4.323 0.458,0.292 10 *1
*1 No. 1 O-ring


Install a new No. 1 O-ring to the vacuum pump housing.

NOTICE:
·

Wipe off any oil on the end cover installation surface and end cover.

·

Check that no foreign matter is on the No. 1 O-ring or inside the vacuum pump housing.




b.
C169335

Using a T25 "TORX" socket wrench, install the end cover with 5 new screws.

Torque:
7.5 N*m (76 kgf*cm, 66 in.*lbf)

NOTICE:
·

Hold the vacuum pump assembly so that its installation surface, fitting parts and oil pipe will not be damaged.

·

As the vacuum pump housing deforms when force is applied, do not hold the vacuum pump housing with a tool such as a vise.

·

Securely fit the T25 "TORX" socket wrench to the screws.




c.
C169333