Home › Vehicle Exterior › LIGHTING (EXT) › LIGHTING SYSTEM › 2016.10–2019.09
RM32H0E _59 Vehicle Exterior _060313 LIGHTING (EXT) _0300012 LIGHTING SYSTEM W

LIGHTING (EXT)  LIGHTING SYSTEM  CUSTOMIZE PARAMETERS  


CUSTOMIZE LIGHTING SYSTEM (EXT)


NOTICE:
·

When the customer requests a change in a function, first make sure that the function can be customized.

·

Be sure to make a note of the current settings before customizing.

·

When troubleshooting a function, first make sure that the function is set to the default setting.



HINT:

The following items can be customized.


a.

Customizing with the GTS

i.

Connect the GTS to the DLC3.


ii.

Turn the ignition switch to ON.


iii.

Turn the GTS on.


iv.

Enter the following menus: Body Electrical / Main Body / Utility / Customize / Light Control, Illuminated Entry or Warning.


v.

Select the setting by referring to the table below.

Light Control
Tester Display Description Default Setting ECU
Response Time Changes the delay timing of lighting the taillights when going into a tunnel when the light control switch is in the AUTO position.*2 Normal 0:Normal,1:Long Main Body ECU (Multiplex Network Body ECU)
Disp Ex ON Sen Changes the ambient brightness level required to dim the lights such as the indicator lights of the combination meter, A/C indicator light and clock.*A NORMAL 000:NORMAL,001:DARK2,010:DARK1,011:LIGHT1,100:LIGHT2 Main Body ECU (Multiplex Network Body ECU)
Disp Ex OFF Sen Changes the ambient brightness level required to cancel the dimming of the lights such as the indicator lights of the combination meter, A/C indicator light and clock.*B NORMAL 000:NORMAL,001:DARK2,010:DARK1,011:LIGHT1,100:LIGHT2 Main Body ECU (Multiplex Network Body ECU)
Light Auto OFF Delay Keep the headlights on for a certain period of time after turning the ignition switch off and closing all doors with the low beam headlights on.*3 30 s 00:OFF,01:30 s,10:60 s,11:90 s Main Body ECU (Multiplex Network Body ECU)
Sensitivity Adjusts the sensitivity of the automatic light control system.*C Normal 000:Normal,001:Dark2,010:Dark1,011:Light1,100:Light2 Main Body ECU (Multiplex Network Body ECU)
Follow Me Home Lighting Time Sets the headlight lighting time after the ignition switch is turned off.*1 30 s 00:30 s,01:60 s,10:90 s,11:120 s Main Body ECU (Multiplex Network Body ECU)
50006 8
Warning
Tester Display Description Default Setting ECU
Lane Change Flashing Times Setting Function to change the lane change flashing times. 3 000:OFF,001:3,010:4,011:5,100:6,101:7 Combination Meter Assembly
50006 7

*1: w/ Follow Me Home System

*2: Vehicles displaying the Item "Response Time" on the GTS

*3: Vehicles displaying the Item "Light Auto OFF Delay" on the GTS


HINT:

The sensitivity adjustment may be difficult to confirm. Check by driving the vehicle.


*A

E259624E01
0.375,0.333 2.292,0.708 1.917,0.375 10 Brightness level required to dim the lights 2.771,0.542 3.385,0.74 0.615,0.198 10 Dark 6.281,0.542 6.896,0.74 0.615,0.198 10 Bright 1.083,1.104 1.729,1.333 0.646,0.229 10 Setting 2.667,1.104 3.313,1.333 0.646,0.229 10 DARK2 3.521,1.104 4.167,1.333 0.646,0.229 10 DARK1 4.406,1.104 5.083,1.333 0.677,0.229 10 NORMAL 5.333,1.104 6.01,1.333 0.677,0.229 10 LIGHT1 6.177,1.104 6.76,1.313 0.583,0.208 10 LIGHT2

*B

E259624E02
0.323,0.302 2.427,0.698 2.104,0.396 10 false Brightness level required to cancel the dimming of the lights 1.104,1.094 2,1.365 0.896,0.271 10 false Setting 2.781,0.531 3.333,0.781 0.552,0.25 10 false Dark 6.313,0.542 6.865,0.792 0.552,0.25 10 false Bright 2.688,1.115 3.24,1.365 0.552,0.25 10 false DARK2 3.573,1.115 4.125,1.365 0.552,0.25 10 false DARK1 4.396,1.115 5.042,1.344 0.646,0.229 10 false NORMAL 6.229,1.115 6.781,1.365 0.552,0.25 10 false LIGHT2 5.344,1.115 5.896,1.365 0.552,0.25 10 false LIGHT1

*C

E259624E03
0.365,0.302 2.354,0.708 1.99,0.406 10 Sensitivity of the automatic light control system 1.104,1.094 2,1.365 0.896,0.271 10 Setting 2.781,0.531 3.333,0.781 0.552,0.25 10 Dark 6.313,0.542 6.865,0.792 0.552,0.25 10 Bright 2.719,1.115 3.271,1.365 0.552,0.25 10 Dark2 3.615,1.115 4.167,1.365 0.552,0.25 10 Dark1 4.469,1.115 5.021,1.365 0.552,0.25 10 Normal 6.271,1.115 6.823,1.365 0.552,0.25 10 Light2 5.375,1.115 5.927,1.365 0.552,0.25 10 Light1


Illuminated Entry
Tester Display Description Default Setting ECU
Mirr-Foot-Lgt Approached/Exterior Light Approached Lights up the door mirror foot lights when a key enters any actuation area around the doors.*1 ON 0:OFF,1:ON Main Body ECU (Multiplex Network Body ECU)
Mirr-Foot-Lgt Unlocked/Exterior Light Unlocked Lights up door mirror foot lights when doors are unlocked using a mechanical key or door control transmitter.*1 ON 0:OFF,1:ON Main Body ECU (Multiplex Network Body ECU)
Mirror Foot Light Time/Exterior Light Time Changes the lighting time of the door mirror foot lights.*1 15 s 00:15 s,01:7.5 s,10:30 s,11:0 s Main Body ECU (Multiplex Network Body ECU)
Exterior Light Control Changes the door mirror foot light control.*1 ON 0:OFF,1:ON Main Body ECU (Multiplex Network Body ECU)
50006 6

*1: w/ Door Mirror Foot Light Control




b.

Customizing with the multi-display

i.

Turn the ignition switch to ON.


ii.

Enter the following menus: MENU / Setup / Vehicle / Vehicle customization / Lights settings.


iii.

Select the setting by referring to the table below.

Lights settings
Tester Display Description Default Setting ECU
Light sensor sensitivity Adjusts the sensitivity of the automatic light control system.*A 0 -2, -1, 0, +1 or +2 Main Body ECU (Multiplex Network Body ECU)
Exterior lights off timer Changes the lighting time of the door mirror foot lights.*1 15 sec. Off, 7.5 sec., 15 sec. or 30 sec. Main Body ECU (Multiplex Network Body ECU)

*1: w/ Door Mirror Foot Light Control


HINT:

The sensitivity adjustment may be difficult to confirm. Check by driving the vehicle.


*A

E259624E05
0.365,0.302 2.354,0.708 1.99,0.406 10 Sensitivity of the automatic light control system 1.104,1.094 2,1.365 0.896,0.271 10 Setting 2.781,0.531 3.333,0.781 0.552,0.25 10 Dark 6.313,0.542 6.865,0.792 0.552,0.25 10 Bright 2.813,1.125 3.365,1.375 0.552,0.25 10 -2 3.708,1.125 4.26,1.375 0.552,0.25 10 -1 4.646,1.125 5.198,1.375 0.552,0.25 10 0 6.375,1.125 6.729,1.323 0.354,0.198 10 +2 5.49,1.125 5.854,1.333 0.365,0.208 10 +1