AIR CONDITIONING AMPLIFIER ASSEMBLY
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Terminal No. (symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| F72-1 (B) - Body ground | V - Body ground | Power source (Back-up) | Always | 11 to 14 V |
| F72-3 (LIN1) - F72-29 (GND) | L - W-B*3
BE - W-B*4 |
LIN communication signal (Air conditioning control assembly) | Ignition switch ON | Pulse generation
(See waveform 1) |
| F72-5 (IG+) - Body ground | B - Body ground | Power Source (IG) | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | |||
| F72-9 (CANH) - F72-10 (CANL) | P - SB | CAN communication | CAN communication is performed | Pulse generation |
| F72-15 (SOL-) - F72-29 (GND)*7 | L - W-B | Compressor solenoid operation | ·
Engine running ·
Blower switch: Lo ·
A/C switch: On |
Pulse generation
(See waveform 2) |
| F72-19 (PTC1) - F72-29 (GND)*1 | L - W-B | Output for driving PTC1 heater relay | ·
Ignition switch ON ·
ECO mode: off ·
Temperature setting: MAX HOT ·
Ambient temperature: 25°C (77°F) or lower ·
Engine coolant temperature: 75°C (167°F) or lower ·
Light control switch off ·
Blower switch: Lo |
Below 1 V |
·
Ignition switch ON ·
ECO mode: off ·
Temperature setting: MAX HOT ·
Ambient temperature: 25°C (77°F) or lower ·
Engine coolant temperature: 75°C (167°F) or lower ·
Light control switch off ·
Blower switch: Off |
11 to 14 V | |||
| F72-20 (PTC3) - F72-29 (GND)*1 | BR - W-B | Output for driving PTC3 heater relay | ·
Ignition switch ON ·
ECO mode: off ·
Temperature setting: MAX HOT ·
Ambient temperature: -7°C (19°F) or lower ·
Engine coolant temperature: 65°C (149°F) or lower ·
Light control switch off ·
Blower switch: Lo |
Below 1 V |
·
Ignition switch ON ·
ECO mode: off ·
Temperature setting: MAX HOT ·
Ambient temperature: -7°C (19°F) or lower ·
Engine coolant temperature: 65°C (149°F) or lower ·
Light control switch off ·
Blower switch: Off |
11 to 14 V | |||
| F72-29 (GND) - Body ground | W-B - Body ground | Ground for main power supply | Always | Below 1 V |
| F72-32 (SG-2) - Body ground*7 | G - Body ground | Ground for air conditioner pressure sensor | Always | Below 1 V |
| F72-33 (PRE) - F72-32 (SG-2)*5,*7 | V - G | Input from refrigerant gas sensor | ·
Ignition switch ON ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (more than 3025 kPa (30.8 kgf/cm2, 439 psi)) |
4.61 V or higher |
·
Ignition switch ON ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (less than 176 kPa (1.8 kgf/cm2, 26 psi)) |
Below 0.74 V | |||
·
Ignition switch ON ·
Air conditioning system operating ·
Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) |
0.74 to 4.61 V | |||
| F72-33 (PRE) - F72-32 (SG-2)*6,*7 | V - G | Input from refrigerant gas sensor | ·
Ignition switch ON ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (more than 2812 kPa (28.7 kgf/cm2, 408 psi)) |
4.61 V or higher |
·
Ignition switch ON ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (less than 195 kPa (2.0 kgf/cm2, 28 psi)) |
Below 0.74 V | |||
·
Ignition switch ON ·
Air conditioning system operating ·
Refrigerant pressure: Normal pressure (less than 2812 kPa (28.7 kgf/cm2, 408 psi) and more than 195 kPa (2.0 kgf/cm2, 28 psi)) |
0.74 to 4.61 V | |||
| F72-34 (S5-3) - F72-32 (SG-2)*7 | GR - G | Power supply for air conditioner pressure sensor | Ignition switch ON | 4.75 to 5.25 V |
| Ignition switch off | Below 1 V | |||
| F72-39 (PTC2) - F72-29 (GND)*1 | V - W-B | Output for driving PTC2 heater relay | ·
Ignition switch ON ·
ECO mode: off ·
Temperature setting: MAX HOT ·
Ambient temperature: 16°C (61°F) or lower ·
Engine coolant temperature: 70°C (158°F) or lower ·
Light control switch off ·
Blower switch: Lo |
Below 1 V |
·
Ignition switch ON ·
ECO mode: off ·
Temperature setting: MAX HOT ·
Ambient temperature: 16°C (61°F) or lower ·
Engine coolant temperature: 70°C (158°F) or lower ·
Light control switch off ·
Blower switch: Off |
11 to 14 V | |||
| F7A-1 (SHUNT1) - Body ground | - | Set HVAC double layer | ·
Ignition switch ON ·
Double Layer*2 |
11 to 14 V |
·
Ignition switch ON ·
Single Layer |
Below 1 V | |||
| F7A-2 (B2AI) - Body ground | - | Output for driving the motor to switch inlet/outlet B2 | ·
Ignition switch ON ·
No. 1 blower damper servo sub-assembly (fresh/recirculation) operating |
Pulse generation
(See waveform 3) |
| F7A-3 (A2AI) - Body ground | - | Output for driving the motor to switch inlet/outlet A2 | ·
Ignition switch ON ·
No. 1 blower damper servo sub-assembly (fresh/recirculation) operating |
Pulse generation
(See waveform 3) |
| F7A-4 (A2AO) - Body ground | - | Output for driving the motor to switch mode A2 | ·
Ignition switch ON ·
No. 2 air conditioning radiator damper servo sub-assembly (mode switching) operating |
Pulse generation
(See waveform 4) |
| F7A-6 (B2AO) - Body ground | - | Output for driving the motor to switch mode B2 | ·
Ignition switch ON ·
No. 2 air conditioning radiator damper servo sub-assembly (mode switching) operating |
Pulse generation
(See waveform 4) |
| F7A-8 (B1AO) - Body ground | - | Output for driving the motor to switch mode B1 | ·
Ignition switch ON ·
No. 2 air conditioning radiator damper servo sub-assembly (mode switching) operating |
Pulse generation
(See waveform 4) |
| F7A-9 (A1AI) - Body ground | - | Output for driving the motor to switch inlet/outlet A1 | ·
Ignition switch ON ·
No. 1 blower damper servo sub-assembly (fresh/recirculation) operating |
Pulse generation
(See waveform 3) |
| F7A-10 (B1AI) - Body ground | - | Output for driving the motor to switch inlet/outlet B1 | ·
Ignition switch ON ·
No. 1 blower damper servo sub-assembly (fresh/recirculation) operating |
Pulse generation
(See waveform 3) |
| F7A-13 (BAI) - Body ground | - | Power supply to the motor to switch inlet/outlet | Ignition switch ON | 11 to 14 V |
| F7A-16 (A1AO) - Body ground | - | Output for driving the motor to switch mode A1 | ·
Ignition switch ON ·
No. 2 air conditioning radiator damper servo sub-assembly (mode switching) operating |
Pulse generation
(See waveform 4) |
| F7A-21 (SHUNT2) - Body ground | - | Set HVAC double layer | ·
Ignition switch ON ·
Double Layer*2 |
11 to 14 V |
·
Ignition switch ON ·
Single Layer |
Below 1 V | |||
| F7A-22 (B1RU) - Body ground | - | Output for driving the air mix motor in right upper layer B1 | ·
Ignition switch ON ·
No. 1 air conditioning radiator damper servo sub-assembly (upper air mix) operating |
Pulse generation
(See waveform 5) |
| F7A-23 (A2RL) - Body ground | - | Output for driving the air mix motor in right lower layer A2 | ·
Ignition switch ON ·
No. 1 air conditioning radiator damper servo sub-assembly (lower air mix) operating |
Pulse generation
(See waveform 6) |
| F7A-24 (A1RU) - Body ground | - | Output for driving the air mix motor in right upper layer A1 | ·
Ignition switch ON ·
No. 1 air conditioning radiator damper servo sub-assembly (upper air mix) operating |
Pulse generation
(See waveform 5) |
| F7A-25 (B2RL) - Body ground | - | Output for driving the air mix motor in right lower layer B2 | ·
Ignition switch ON ·
No. 1 air conditioning radiator damper servo sub-assembly (lower air mix) operating |
Pulse generation
(See waveform 6) |
| F7A-26 (B1RL) - Body ground | - | Output for driving the air mix motor in right lower layer B1 | ·
Ignition switch ON ·
No. 1 air conditioning radiator damper servo sub-assembly (lower air mix) operating |
Pulse generation
(See waveform 6) |
| F7A-27 (A2RU) - Body ground | - | Output for driving the air mix motor in right upper layer A2 | ·
Ignition switch ON ·
No. 1 air conditioning radiator damper servo sub-assembly (upper air mix) operating |
Pulse generation
(See waveform 5) |
| F7A-28 (A1RL) - Body ground | - | Output for driving the air mix motor in right lower layer A1 | ·
Ignition switch ON ·
No. 1 air conditioning radiator damper servo sub-assembly (lower air mix) operating |
Pulse generation
(See waveform 6) |
| F7A-29 (B2RU) - Body ground | - | Output for driving the air mix motor in right upper layer B2 | ·
Ignition switch ON ·
No. 1 air conditioning radiator damper servo sub-assembly (upper air mix) operating |
Pulse generation
(See waveform 5) |
| F7A-32 (BAO) - Body ground | - | Power supply to the motor to switch mode | Ignition switch ON | 11 to 14 V |
| F7A-33 (BRU) - Body ground | - | Power supply to the air mix motor in right upper layer | Ignition switch ON | 11 to 14 V |
| F7A-34 (BRL) - Body ground | - | Power supply to the air mix motor in right lower layer | Ignition switch ON | 11 to 14 V |
| F7A-38 (TEA) - F7A-39 (SGA) | - | Input No. 1 cooler thermistor | ·
Ignition switch ON ·
Evaporator temperature: 0°C (32°F) |
0.5 V |
·
Ignition switch ON ·
Evaporator temperature: 25°C (77°F) |
1.6 V | |||
| F7A-39 (SGA) - Body ground | - | Ground for No. 1 cooler thermistor | Always | Below 1 V |
| F7A-40 (BLW) - F72-29 (GND) | - | Output for driving Blower motor | ·
Ignition switch ON ·
Blower switch: Lo |
Pulse generation
(See waveform 4) |
*1: w/ PTC Heater
*2: w/ Headlight Cleaner System
*3: for LHD
*4: for RHD
*5: for HFC-134a (R134a)
*6: for HFO-1234yf (R1234yf)
*7: w/ Cooler System
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. | F72-3 (LIN1) - F72-29 (GND) |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Vehicle Condition | Ignition switch ON |
Waveform 2:
| Item | Content |
|---|---|
| Terminal No. | F72-15 (SOL-) - F72-29 (GND) |
| Tool Setting | 5 V/DIV., 1 ms./DIV. |
| Vehicle Condition | ·
Engine running ·
Blower switch: Lo ·
A/C switch: On |
Waveform 3:
| Item | Content |
|---|---|
| Terminal No. | F7A-2 (B2AI) - Body ground |
| F7A-3 (A2AI) - Body ground | |
| F7A-9 (A1AI) - Body ground | |
| F7A-10 (B1AI) - Body ground | |
| Tool Setting | 2 V/DIV., 10 ms./DIV. |
| Vehicle Condition | ·
Ignition switch ON ·
No. 1 blower damper servo sub-assembly (fresh/recirculation) operating |
Waveform 4:
| Item | Content |
|---|---|
| Terminal No. | F7A-4 (A2AO) - Body ground |
| F7A-6 (B2AO) - Body ground | |
| F7A-8 (B1AO) - Body ground | |
| F7A-16 (A1AO) - Body ground | |
| Tool Setting | 2 V/DIV., 10 ms./DIV. |
| Vehicle Condition | ·
Ignition switch ON ·
No. 2 air conditioning radiator damper servo sub-assembly (mode switching) operating |
Waveform 5:
| Item | Content |
|---|---|
| Terminal No. | F7A-22 (B1RU) - Body ground |
| F7A-24 (A1RU) - Body ground | |
| F7A-27 (A2RU) - Body ground | |
| F7A-29 (B2RU) - Body ground | |
| Tool Setting | 2 V/DIV., 10 ms./DIV. |
| Vehicle Condition | ·
Ignition switch ON ·
No. 1 air conditioning radiator damper servo sub-assembly (upper air mix) operating (for LHD) |
Waveform 6:
| Item | Content |
|---|---|
| Terminal No. | F7A-23 (A2RL) - Body ground |
| F7A-25 (B2RL) - Body ground | |
| F7A-26 (B1RL) - Body ground | |
| F7A-28 (A1RL) - Body ground | |
| Tool Setting | 2 V/DIV., 10 ms./DIV. |
| Vehicle Condition | ·
Ignition switch ON ·
No. 1 air conditioning radiator damper servo sub-assembly (lower air mix) operating (for LHD) |
Waveform 7:
| Item | Content |
|---|---|
| Terminal No. | F7A-40 (BLW) - F72-29 (GND) |
| Tool Setting | 2 V/DIV., 1 ms./DIV. |
| Vehicle Condition | ·
Ignition switch ON ·
Blower switch: Lo |
AIR CONDITIONING CONTROL ASSEMBLY
Check from the rear of the connector while it is connected to the air conditioning control assembly.
| Terminal No. (symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| F61-2 (LIN1) - Body ground | L - Body ground | LIN communication | Ignition switch ON | Pulse generation (See waveform 1) |
| F61-10 (IG+) - Body ground | BE - Body ground | Power source (IG) | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | |||
| F61-16 (GND) - Body ground | W-B - Body ground | Ground for air conditioning control assembly | Always | Below 1 V |
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. | F61-2 (LIN1) - Body ground |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Vehicle Condition | Ignition switch ON |