Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Manual Air Conditioning System)
RM32H0E _58 Vehicle Interior _059841 HEATING / AIR CONDITIONING _0298709 AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  DATA LIST / ACTIVE TEST  


DATA LIST


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Data List.


e.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Ambient Temp Sensor Thermistor assembly Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed -
Adjusted Ambient Temp Adjusted ambient temperature Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F)
- -
Evaporator Fin Thermistor No. 1 cooler thermistor (evaporator temperature sensor) Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed *2
Evaporator Target Temp Evaporator target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed *2
Regulator Control Current Solenoid valve control current Min.: 0 A
Max.: 0.997 A
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation *2
Electric Heater Count Maximum electric heater operation level Min.: 0
Max.: 3
Maximum possible operation level of electric heater displayed *1
Electric Heater Active Level Actual electric heater operation level Min.: 0
Max.: 3
Actual operation level of electric heater displayed *1
A/C Cutoff Signal A/C control cutoff signal ON or OFF A/C switch on: OFF
A/C switch off: ON
*2
Refrigerant Gas Type Refrigerant gas type R134a or 1234yf Refrigerant gas type displayed *2
Number of Trouble Codes Number of trouble codes Min.: 0
Max.: 255
Number of DTCs displayed -
Upper Air Mix Target Position (Driver Side) No. 1 air conditioning radiator damper servo sub-assembly (upper air mix) target position Min.: 0
Max.: 100
·

MAX COLD: 0 (%)

·

MAX HOT: 100 (%)


-
Upper Air Mix Current Position (Driver Side) No. 1 air conditioning radiator damper servo sub-assembly (upper air mix) current position Min.: 0
Max.: 100
·

MAX COLD: 0 (%)

·

MAX HOT: 100 (%)


-
Lower Air Mix Target Position (Driver Side) No. 1 air conditioning radiator damper servo sub-assembly (lower air mix) target position Min.: 0
Max.: 100
·

MAX COLD: 0 (%)

·

MAX HOT: 100 (%)


-
Lower Air Mix Current Position (Driver Side) No. 1 air conditioning radiator damper servo sub-assembly (lower air mix) current position Min.: 0
Max.: 100
·

MAX COLD: 0 (%)

·

MAX HOT: 100 (%)


-
Front Air Outlet Target Position No. 2 air conditioning radiator damper servo sub-assembly (mode switching) target position Min.: 0
Max.: 100
·

FACE: 0 (%)

·

B/L: 36 (%)

·

FOOT: 61 (%)

·

FOOT/DEF: 71 (%)

·

DEF: 100 (%)


-
Front Air Outlet Current Position No. 2 air conditioning radiator damper servo sub-assembly (mode switching) actual position Min.: 0
Max.: 100
·

FACE: 0 (%)

·

B/L: 36 (%)

·

FOOT: 61 (%)

·

FOOT/DEF: 71 (%)

·

DEF: 100 (%)


-
Air Inlet Target Position No. 1 blower damper servo sub-assembly target position Min.: 0
Max.: 100
w/o Headlight Cleaner System
·

Recirculation: 100 (%)

·

Fresh: 0 (%)


w/ Headlight Cleaner System
·

Recirculation: 50 (%)

·

Bi-layer: 100 (%)

·

Fresh: 0 (%)


-
Air Inlet Current Position No. 1 blower damper servo sub-assembly current position Min.: 0
Max.: 100
w/o Headlight Cleaner System
·

Recirculation: 100 (%)

·

Fresh: 0 (%)


w/ Headlight Cleaner System
·

Recirculation: 50 (%)

·

Bi-layer: 100 (%)

·

Fresh: 0 (%)


-
Engine Coolant Temperature Engine coolant temperature sensor Min.: 0.5°C (32.9°F)
Max.: 127.5°C (261.5°F)
Actual engine coolant temperature displayed -
Regulator Pressure Sensor Air conditioner pressure sensor Min.: 0 kPa
Max.: 3760 kPa
Actual refrigerant pressure displayed -
Air Outlet Target Temperature (Driver Side) Air outlet target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Actual air outlet target temperature displayed -

*1: w/ PTC Heater

*2: w/ Cooler System




ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Magnetic Clutch Relay Air conditioning system operation OFF or ON *2
Heater Active Level Quick heater assembly OFF or ON *1
Blower Motor Blower motor with fan sub-assembly Min.: 0
Max.: 100
Operates between
0 to 100%
Air Inlet No. 1 blower damper servo sub-assembly (fresh/recirculation) Min.: 0
Max.: 100
Operates between
0 to 100%
Air Outlet (Front) No. 2 air conditioning radiator damper servo sub-assembly (mode switching) Min.: 0
Max.: 100
Operates between
0 to 100%
Upper Air Mix (Driver Side) No. 1 air conditioning radiator damper servo sub-assembly (upper air mix) Min.: 0
Max.: 100
Operates between
0 to 100%
Lower Air Mix (Driver Side) No. 1 air conditioning radiator damper servo sub-assembly (lower air mix) Min.: 0
Max.: 100
Operates between
0 to 100%

*1: w/ PTC Heater

*2: w/ Cooler System