AIR CONDITIONING AMPLIFIER ASSEMBLY
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| F71-1 (SG-1) - Body ground | LG - Body ground | Ground for cooler (room temp. sensor) thermistor | Always | Below 1 V |
| F71-2 (SG-2) - Body ground | G - Body ground | Ground for air conditioner pressure sensor | Always | Below 1 V |
| F71-6 (S5-3) - F71-2 (SG-2) | GR - G | Power supply for air conditioner pressure sensor | Ignition switch ON | 4.75 to 5.25 V |
| Ignition switch off | Below 1 V | |||
| F71-14 (TR) - F71-1 (SG-1) | B - LG | Cooler (room temp. sensor) thermistor signal | ·
Ignition switch ON ·
Cabin temperature: 25°C (77°F) |
1.8 to 2.2 V |
·
Ignition switch ON ·
Cabin temperature: 40°C (104°F) |
1.2 to 1.6 V | |||
| F71-24 (PRE) - F71-2 (SG-2) | V - G | Air conditioner pressure sensor signal | ·
Engine running ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (more than 3.025 MPaG (30.8 kgf/cm2, 439 psi)*2, more than 2.812 MPaG (28.7 kgf/cm2, 408 psi)*3) |
4.61 V or higher |
·
Engine running ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (less than 0.176 MPaG (1.8 kgf/cm2, 26 psi)*2, less than 0.196 MPaG (2.0 kgf/cm2, 28 psi) or less*3) |
Below 0.74 V | |||
·
Engine running ·
Air conditioning system operating ·
Refrigerant pressure: Normal pressure (less than 3.025 MPaG (30.8 kgf/cm2, 439 psi) and more than 0.176 MPaG (1.8 kgf/cm2, 26 psi)*2, less than 2.812 MPaG (28.7 kgf/cm2, 408 psi) and more than 0.196 MPaG (2.0 kgf/cm2, 28 psi)*3) |
0.74 to 4.61 V | |||
| F73-1 (B) - F73-4 (GND) | V - W-B | Power source (Back-up) | Always | 11 to 14 V |
| F73-2 (IG+) - F73-4 (GND) | B - W-B | Power source (IG) | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | |||
| F73-3 (SOL+) - F73-4 (GND) | B - W-B | Compressor solenoid operation signal | ·
Engine running ·
Blower switch: Lo ·
A/C switch: On |
Pulse generation
(See waveform 1) |
| F73-4 (GND) - Body ground | W-B - Body ground | Ground for main power supply | Always | Below 1 V |
| F73-6 (BLW) - F73-4 (GND) | Y - W-B | Blower motor speed control signal | ·
Ignition switch ON ·
Blower switch: Lo |
Pulse generation
(See waveform 2) |
| F73-11 (CANH) - F73-12 (CANL) | P - SB | CAN communication signal | CAN communication is performed | Pulse generation |
| F73-14 (LIN1) - F73-4 (GND) | BE - W-B | LIN communication signal (Air conditioning control assembly) | Ignition switch ON | Pulse generation
(See waveform 3) |
| F73-7 (NANO) - F73-4 (GND)*1 | R - W-B | Ion generator sub-assembly operation signal | ·
Ignition switch ON ·
Blower switch: Lo ·
"nanoe" switch: On |
Below 1 V |
·
Ignition switch ON ·
Blower switch: Lo ·
"nanoe" switch: off |
11 to 14 V | |||
| F73-26 (NAIN) - F73-4 (GND)*1 | W - W-B | Ion generator sub-assembly operation condition signal | ·
Ignition switch ON ·
Blower switch: Lo ·
"nanoe" switch: On |
Below 1 V |
·
Ignition switch ON ·
Blower switch: Lo ·
"nanoe" switch: off |
4.75 to 5.25 V | |||
| m5-2 (BUSG) - Body ground | B - Body ground | Ground for BUS IC | Always | Below 1 V |
| m5-3 (BUS) - m5-2 (BUSG) | L - B | BUS IC control signal | Ignition switch ON | Pulse generation
(See waveform 4) |
| m5-4 (BUSB) - m5-2 (BUSG) | R - B | Power supply for BUS IC | Always | 11 to 14 V |
| m5-5 (SG-3) - Body ground | GR - Body ground | Ground for No. 1 cooler thermistor (evaporator temperature sensor) | Always | Below 1 V |
| m5-6 (TE) - m5-5 (SG-3) | GR - GR | No. 1 cooler thermistor (evaporator temperature sensor) | ·
Ignition switch ON ·
Evaporator temperature: 0°C (32°F) |
1.7 to 2.1 V |
·
Ignition switch ON ·
Evaporator temperature: 15°C (59°F) |
0.9 to 1.3 V |
*1: w/ Ion Generator
*2: for HFC-134a (R134a)
*3: for HFO-1234yf (R1234yf)
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. (Symbol) | F73-3 (SOL+) - F73-4 (GND) |
| Tool Setting | 5 V/DIV., 500 μs./DIV. |
| Vehicle Condition | ·
Engine running ·
Blower switch: Lo ·
A/C switch: on |
Waveform 2:
| Item | Content |
|---|---|
| Terminal No. | F73-6 (BLW) - F73-4 (GND) |
| Tool Setting | 2 V/DIV., 1 ms./DIV. |
| Vehicle Condition | ·
Ignition switch ON ·
Blower switch: Lo |
Waveform 3:
| Item | Content |
|---|---|
| Terminal No. | F73-14 (LIN1) - F73-4 (GND) |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Vehicle Condition | Ignition switch ON |
Waveform 4:
| Item | Content |
|---|---|
| Terminal No. | m5-3 (BUS) - m5-2 (BUSG) |
| Tool Setting | 2 V/DIV., 2 ms./DIV. |
| Vehicle Condition | Ignition switch ON |
AIR CONDITIONING CONTROL ASSEMBLY
Check from the rear of the connector while it is connected to the air conditioning control assembly.
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| F61-16 (GND) - Body ground | W-B - Body ground | Ground for air conditioning control assembly | Always | Below 1 V |
| F61-2 (LIN1) - Body ground | BE - Body ground | LIN communication signal | Ignition switch ON | Pulse generation
(See waveform 1) |
| F61-10 (IG+) - F61-16 (GND) | BE - W-B | Power source (IG) | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V |
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. | F61-2 (LIN1) - Body ground |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Vehicle Condition | Ignition switch ON |