Home › Power Source / Network › 8NR-FTS (BATTERY / CHARGING) › CHARGING SYSTEM › from 2021.09
RM32H0E _57 Power Source / Network _060209 8NR-FTS BATTERY / CHARGING _0295688 CHARGING SYSTEM U

8NR-FTS BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECM  


CHECK ECM


A384862C11
2.417,0.75 2.917,1 0.5,0.25 5.323,0.75 5.833,1 0.51,0.25 2.406,0.354 2.906,0.604 0.5,0.25 2.521,0.802 2.979,1 0.458,0.198 10 false C74 5.427,0.802 5.885,1 0.458,0.198 10 false A38 2.521,0.396 2.979,0.594 0.458,0.198 10 false C62 3.031,0.375 3.49,0.573 0.458,0.198 12 false *A 3.052,0.781 3.51,0.979 0.458,0.198 12 false *B
*A for TMMT Made *B for TMC Made


HINT:

The standard normal voltage between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


for TMMT Made
Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
C62-53 (E1) - Body ground W-B - Body ground Ground Always Below 1 Ω
A38-1 (BATT) - C62-53 (E1) B - W-B Battery (for measuring battery voltage and for ECM memory) Always 11 to 14 V
C62-61 (LIN) - Body ground B - Body ground LIN communication line Ignition switch off
(while LIN communication stopped)
10 kΩ or higher

for TMC Made
Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
C74-53 (E1) - Body ground W-B - Body ground Ground Always Below 1 Ω
A38-1 (BATT) - C74-53 (E1) B - W-B Battery (for measuring battery voltage and for ECM memory) Always 11 to 14 V
C74-61 (LIN) - Body ground B - Body ground LIN communication line Ignition switch off
(while LIN communication stopped)
10 kΩ or higher