2006-2011 Camry Aurion · Service Manual ENGINE

P0037 Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2)

Diagnostic trouble codes · Vehicles built Oct 2006 – May 2009

Also covers:

Versions by build date: Oct 2006 – May 2009 from Jun 2009

DESCRIPTION

A three-way catalytic converter (TWC) is used in order to convert the carbon monoxide (CO), hydrocarbon (HC), and nitrogen oxide (NOx) into less harmful substances. To allow the TWC to function effectively, it is necessary to keep the air-fuel ratio of the engine near the stoichiometric air-fuel ratio. For the purpose of helping the ECM to deliver accurate air-fuel ratio control, a Heated Oxygen (HO2) sensor is used.
The HO2 sensor is located behind the TWC, and detects the oxygen concentration in the exhaust gas. Since the sensor is integrated with the heater that heats the sensing portion, it is possible to detect the oxygen concentration even when the intake air volume is low (the exhaust gas temperature is low).
When the air-fuel ratio becomes lean, the oxygen concentration in the exhaust gas becomes rich. The HO2 sensor informs the ECM that the post-TWC air-fuel ratio is lean (low voltage, i.e. less than 0.45 V).
Conversely, when the air-fuel ratio is richer than the stoichiometric air-fuel level, the oxygen concentration in the exhaust gas becomes lean. The HO2 sensor informs the ECM that the post-TWC air-fuel ratio is rich (high voltage, i.e. more than 0.45 V). The HO2 sensor has the property of changing its output voltage drastically when the air-fuel ratio is close to the stoichiometric level.
The ECM uses the supplementary information from the HO2 sensor to determine whether the air-fuel ratio after the TWC is rich or lean, and adjusts the fuel injection time accordingly. Thus, if the HO2 sensor is working improperly due to internal malfunctions, the ECM is unable to compensate for deviations in the primary air-fuel ratio control.
A088111E14

HINT:
  1. Sensor 2 refers to the sensor mounted behind the Three-Way Catalytic Converter (TWC) and located far from the engine assembly.
  2. When any of these DTCs are set, the ECM enters fail-safe mode. The ECM turns off the Heated Oxygen (HO2) sensor heater in fail-safe mode. Fail-safe mode continues until the ignition switch is turned off.

  3. The ECM provides a pulse width modulated control circuit to adjust the current through the heater. The HO2 sensor heater circuit uses a relay on the B+ side of the circuit.

    A103832E53
DTC No.
DTC Detection Condition
Trouble Area
P0037
P0057
Heated Oxygen (HO2) sensor heater current is less than 0.3 A (1 trip detection logic)
  1. Open in HO2 sensor heater circuit
  2. HO2 sensor heater
  3. Engine room junction block
  4. ECM
P0038
P0058
Heated Oxygen (HO2) sensor heater current is more than 3.5 A (1 trip detection logic)
  1. Short in HO2 sensor heater circuit
  2. HO2 sensor heater
  3. Engine room junction block
  4. ECM

HINT:
  1. Bank 1 refers to the bank that includes cylinder No. 1.
  2. Bank 2 refers to the bank that does not include cylinder No. 1.
  3. Sensor 1 refers to the sensor closest to the engine assembly.
  4. Sensor 2 refers to the sensor farthest away from the engine assembly.


WIRING DIAGRAM

Refer to DTC P0136 (Click here).

INSPECTION PROCEDURE

HINT:
Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction (Click here).


1. INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)

  1. A137614E15
    Disconnect the C52 heated oxygen sensor connector (Bank 1 Sensor 2) or C51 heated oxygen sensor connector (Bank 2 Sensor 2).

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Bank 1 sensor 2:
    Tester Connection
    Condition
    Specified Condition
    HT1B (1) - +B (2)
    20°C (68°F)
    11 to 16 Ω
    HT1B (1) - E2 (4)
    Always
    10 kΩ or higher
    Bank 2 sensor 2:
    Tester Connection
    Condition
    Specified Condition
    HT2B (1) - +B (2)
    20°C (68°F)
    11 to 16 Ω
    HT2B (1) - E2 (4)
    Always
    10 kΩ or higher

  1. Reconnect the HO2 sensor connector.



NG
REPLACE HEATED OXYGEN SENSOR (Click here)
OK


2. CHECK TERMINAL VOLTAGE (+B OF HO2 SENSOR)

  1. A137619E06
    Disconnect the C52 heated oxygen sensor connector (Bank 1 Sensor 2) or C51 heated oxygen sensor connector (Bank 2 Sensor 2).

  1. Turn the ignition switch on (IG).

  1. Measure the voltage between the terminals.

    Standard voltage:
    Tester Connection
    Specified Condition
    +B (C52-2) - Body ground
    9 to 11 V
    +B (C51-2) - Body ground
    9 to 11 V

  1. Reconnect the HO2 sensor connector.



OK
Go to step 7
NG


3. INSPECT FUSE (EFI NO. 3)

  1. A135018E01
    Remove the EFI No. 3 fuse from the engine room R/B.

  1. Measure the EFI No. 3 fuse resistance.

    Standard resistance:
    Below 1 Ω

  1. Reinstall the EFI No. 3 fuse.



NG
REPLACE EFI NO. 3 FUSE
OK


4. INSPECT ENGINE ROOM JUNCTION BLOCK

  1. A150648E03
    Remove the engine room junction block from the engine room R/B.

  1. Inspect the EFI relay.

    1. Measure the EFI relay resistance.

      Standard resistance:
      Tester Connection
      Specified Condition
      1E-12 - 1E-6
      10 kΩ or higher
      1E-12 - 1E-6
      Below 1 Ω (Apply battery voltage between terminals 1E-9 and 1E-10)

  1. Reinstall the engine room junction block.



NG
REPLACE ENGINE ROOM JUNCTION BLOCK
OK


5. INSPECT FUSE (EFI MAIN)

  1. A135017E01
    Remove the EFI MAIN fuse from the engine room R/B.

  1. Measure the EFI MAIN fuse.

    Standard resistance:
    Below 1 Ω

  1. Reinstall the EFI MAIN fuse.



NG
REPLACE EFI MAIN FUSE
OK


6. CHECK HARNESS AND CONNECTOR (HO2 SENSOR - EFI RELAY)

  1. A140656E01
    Disconnect the C52 or C51 HO2 sensor connector.

  1. Remove the engine room junction block from the engine room R/B.

  1. Measure the resistance between the terminals.

    Standard resistance:
    Check for open:
    Tester Connection
    Specified Condition
    +B (C52-2) - 1E-6 (Engine room R/B)
    Below 1 Ω
    +B (C51-2) - 1E-6 (Engine room R/B)
    Below 1 Ω
    Check for short:
    Tester Connection
    Specified Condition
    +B (C52-2) or 1E-6 (Engine room R/B) - Body ground
    10 kΩ or higher
    +B (C51-2) or 1E-6 (Engine room R/B) - Body ground
    10 kΩ or higher

  1. Reinstall the engine room junction block.

  1. Reconnect the HO2 sensor connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

CHECK ECM POWER SOURCE CIRCUIT

7. CHECK HARNESS AND CONNECTOR (HO2 SENSOR - ECM)

  1. A137615E02
    Disconnect the C52 heated oxygen sensor connector (Bank 1 Sensor 2) or C51 heated oxygen sensor connector (Bank 2 Sensor 2).

  1. Turn the ignition switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Terminal Connection
    Specified Condition
    +B (C52-2) - Body ground
    9 to 14 V
    +B (C51-2) - Body ground
    9 to 14 V

  1. Turn the ignition switch off.

  1. Disconnect the C58 (RHD) or C55 (LHD) ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    RHD:
    Terminal Connection
    Specified Condition
    HT1B (C52-1) - HT1B (C58-48)
    Below 1 Ω
    OX1B (C52-3) - OX1B (C58-88)
    Below 1 Ω
    E2 (C52-4) - EX1B (C58-65)
    Below 1 Ω
    HT2B (C51-1) - HT2B (C58-47)
    Below 1 Ω
    OX2B (C51-3) - OX2B (C58-87)
    Below 1 Ω
    E2 (C51-4) - EX2B (C58-64)
    Below 1 Ω
    LHD:
    Terminal Connection
    Specified Condition
    HT1B (C52-1) - HT1B (C55-48)
    Below 1 Ω
    OX1B (C52-3) - OX1B (C55-88)
    Below 1 Ω
    E2 (C52-4) - EX1B (C55-65)
    Below 1 Ω
    HT2B (C51-1) - HT2B (C55-47)
    Below 1 Ω
    OX2B (C51-3) - OX2B (C55-87)
    Below 1 Ω
    E2 (C51-4) - EX2B (C55-64)
    Below 1 Ω


    Standard resistance (Check for short):
    RHD:
    Terminal Connection
    Specified Condition
    HT1B (C52-1) or HT1B (C58-48) - Body ground
    10 kΩ or higher
    OX1B (C52-3) or OX1B (C58-88) - Body ground
    10 kΩ or higher
    E2 (C52-4) or EX1B (C58-65) - Body ground
    10 kΩ or higher
    HT2B (C51-1) or HT2B (C58-47) - Body ground
    10 kΩ or higher
    OX2B (C51-3) or OX2B (C58-87) - Body ground
    10 kΩ or higher
    E2 (C51-4) or EX2B (C58-64) - Body ground
    10 kΩ or higher
    LHD:
    Terminal Connection
    Specified Condition
    HT1B (C52-1) or HT1B (C55-48) - Body ground
    10 kΩ or higher
    OX1B (C52-3) or OX1B (C55-88) - Body ground
    10 kΩ or higher
    E2 (C52-4) or EX1B (C55-65) - Body ground
    10 kΩ or higher
    HT2B (C51-1) or HT2B (C55-47) - Body ground
    10 kΩ or higher
    OX2B (C51-3) or OX2B (C55-87) - Body ground
    10 kΩ or higher
    E2 (C51-4) or EX2B (C55-64) - Body ground
    10 kΩ or higher

  1. Reconnect the HO2 sensor connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


8. CHECK WHETHER DTC OUTPUT RECURS
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the intelligent tester on.

  1. Clear the DTCs (Click here).

  1. Start the engine.

  1. Allow the engine to idle for 2 minutes.

  1. Select the following menu items: Powertrain / Engine / DTC.

  1. Read the DTCs.

    Result:
    Display (DTC Output)
    Proceed to
    No output
    A
    P0037, P0038, P0057 and/or P0058
    B



B
REPLACE ECM (Click here)
A

CHECK FOR INTERMITTENT PROBLEMS


← P0031 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 1 Sensor 1) (+ P0032, P0051, P0052) (from Jun 2009)P0037 Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2) (+ P0038, P0057, P0058) (from Jun 2009) →