B1413/13 Evaporator Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built from Jun 2006
DESCRIPTION
The evaporator temperature sensor (A/C thermistor) is installed on the evaporator in the air conditioning unit. It detects the temperature of the cooled air that has passed through the evaporator and its signal is used to control the air conditioning. It sends a signal to the A/C amplifier. The resistance of the evaporator temperature sensor (A/C thermistor) changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The A/C amplifier applies voltage (5 V) to the evaporator temperature sensor (A/C thermistor) and reads voltage changes as the resistance of the evaporator temperature sensor (A/C thermistor) changes. This sensor is used to prevent the evaporator from freezing.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1413/13 |
Open or short in evaporator temperature sensor circuit |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE ON INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch on.
Select the item below in the Data List, and read the display on the intelligent tester.
Data List / Air Conditioner: Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Evaporator Fin Thermistor
(Evap Fin Temp)
Evaporator fin thermistor / Min.: -29.7°C (-21.46°F), Max.: 59.55°C (139.19°F)
Actual evaporator temperature is displayed
Open in circuit: -29.7°C (-21.46°F)
Short in circuit: 59.55°C (139.19°F)
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
Proceed to
NG
A
OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
B
OK (When troubleshooting according to the DTC)
C
|
|
||||
|
|
||||
| A | |
| 2. INSPECT EVAPORATOR TEMPERATURE SENSOR |
Disconnect the connector from the evaporator temperature sensor.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
e2-1 - e2-2
-10°C (14°F)
7.30 to 9.10 kΩ
e2-1 - e2-2
-5°C (23°F)
5.65 to 6.95 kΩ
e2-1 - e2-2
0°C (32°F)
4.40 to 5.35 kΩ
e2-1 - e2-2
5°C (41°F)
3.40 to 4.15 kΩ
e2-1 - e2-2
10°C (50°F)
2.70 to 3.25 kΩ
e2-1 - e2-2
15°C (59°F)
2.14 to 2.58 kΩ
e2-1 - e2-2
20°C (68°F)
1.71 to 2.05 kΩ
e2-1 - e2-2
25°C (77°F)
1.38 to 1.64 kΩ
e2-1 - e2-2
30°C (86°F)
1.11 to 1.32 kΩ
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
|
|
||||
| OK | |
| 3. INSPECT AIR CONDITIONING HARNESS |
Remove the air conditioning harness.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
(Symbols)
Condition
Specified Condition
e1-6 (TEA) - e2-2
Always
Below 1 Ω
e1-5 (SGA) - e2-1
Always
Below 1 Ω
e1-6 (TEA) - Body ground
Always
10 kΩ or higher
e1-5 (SGA) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||