2006-2011 Camry Aurion · Service Manual HEATER & AIR CONDITIONING SYSTEM

Blower Motor Circuit

Circuit diagnosis · Vehicles built from Oct 2006

Versions by build date: Jun 2006 – Sep 2006 from Oct 2006

DESCRIPTION

E107334E04
The blower motor is operated by signals from the A/C amplifier. The blower motor speed is controlled using various duty ratios.
Duty Ratio:
  1. The duty ratio is the ratio of the blower motor ON time (A) to the total of the blower motor ON and OFF time (A + B).
  2. The blower motor controller controls the blower motor speed.

WIRING DIAGRAM

E116881E05

INSPECTION PROCEDURE


1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and turn the intelligent tester main switch on.

  1. Select the item below in the Active Test and then check that the blower motor operates.

Active Test / Air Conditioner: 
Tester Display
Test Part
Control Range
Blower Motor
(Blower Motor)
Blower motor / Min.: Level 01, Max.: Level 31
-

Result:
Result
Proceed to
OK
A
NG (Blower motor does not operate)
B
NG (Blower motor operates but does not change speed)
C



B
Go to step 2

C
Go to step 6
A

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

2. INSPECT FUSIBLE LINK (HTR)

  1. C136500E03
    Remove the fusible link from the engine room R/B.

  1. E130412E01
    Check if the fusible link is melted.

    OK:
    The point indicated by "A" is not melted.

  1. Install the fusible link to the engine room R/B with the nut.



NG
REPLACE FUSIBLE LINK (HTR)
OK


3. CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BODY GROUND)

  1. I041124E15
    Disconnect the blower motor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    E39-1 (GND) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4. CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BATTERY)

  1. I041124E16
    Disconnect the blower motor connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    E39-3 (+B) - Body ground
    Always
    10 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5. CHECK HARNESS AND CONNECTOR (A/C AMPLIFIER - BLOWER MOTOR)

  1. E124470E12
    Disconnect the A/C amplifier connector.

  1. I041124E17
    Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    (Symbols)
    Condition
    Specified Condition
    E39-2 (SI) - E38-23 (BLW)
    Always
    Below 1 Ω
    E39-2 (SI) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6. INSPECT BLOWER MOTOR
  1. Reconnect the connector to the blower motor.

  1. E124470E12
    Measure the voltage on the A/C amplifier connector side according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    E38-23 (BLW) - Body ground
    Ignition switch on (IG)
    4.5 to 5.5 V



NG
REPLACE BLOWER MOTOR
OK


7. INSPECT AIR CONDITIONING AMPLIFIER
  1. Remove the A/C amplifier.

  1. E124471E06
    Reconnect the connector to the A/C amplifier.

  1. E103396E01
    Turn the ignition switch on (IG).

  1. Turn the blower switch on.

  1. Measure the waveform between terminal E38-23 (BLW) of the A/C amplifier and body ground.

    OK:
    Waveform is as shown in the illustration.

    HINT:
    Waveform varies with the blower level.

Item
Contents
Tool setting
1 V/DIV., 500 μs/DIV.
Vehicle condition
Ignition switch on (IG)
Blower switch: ON


NG
REPLACE AIR CONDITIONING AMPLIFIER
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE