OPERATION CHECK
Troubleshooting · Vehicles built from Jun 2009
| SELF-CHECK FUNCTION INSPECTION |
Turn the ignition switch on (IG).

When the clearance sonar main switch is turned on, check that the following occurs: 1) after 0.4 milliseconds, the buzzer sounds for approximately 1 +/- 0.3 seconds, and 2) the system starts the obstacle detection operation.
- HINT:
- If a sensor has an open circuit or a sensor detection operation malfunctions because it is wet or frozen, the buzzer sounds.
- When the sensor condition returns to normal, the system ends normal clearance sonar mode.
- If the ignition switch is turned on (IG) after the clearance sonar main switch is turned on, the buzzer does not sound.
- If a sensor has an open circuit or a sensor detection operation malfunctions because it is wet or frozen, the buzzer sounds.
| MALFUNCTION BUZZER |
Ultrasonic sensor open circuit
If there is an open circuit between the ultrasonic sensors and the clearance warning ECU or if a sensor is malfunctioning, the malfunction buzzer sounds as shown in the illustration.


| DETECTION RANGE MEASUREMENT |
Detection range measurement
- NOTICE:
- Make sure that the vehicle does not move by applying the parking brake firmly.
Turn the ignition switch on (IG).
Move the shift lever to R to check the ultrasonic sensors (rear sensors).
Turn the clearance sonar main switch on.
Move a 60 mm (2.36 in.) diameter pole near each sensor to measure its detection range.


- NOTICE:
- These detection ranges are applicable when positioning the 60 mm (2.36 in.) diameter pole parallel or perpendicular to the ground. The detection range varies depending on the measuring method and type of obstacle (such as walls).
When the ultrasonic sensors (back sonar) have detected an obstacle, check buzzer sound.
Operation Condition Ignition Switch
Clearance Sonar Main Switch
Shift Lever Position
On (IG)
On
R


- Standard:
Detection Range
During Detection
Obstacle
*1
Close-range detection
Within approx. 350 +/- 40 mm (13.78 +/- 1.57 in.)
Buzzer: Sounds continuously
60 mm (2.36 in.) diameter pole
*2
Medium-range detection
From approx. 350 +/- 40 to 450 +/- 50 mm (13.78 +/- 1.57 to 17.72 +/- 1.97 in.)
Buzzer: Sounds intermittently (ON: 75 ms. / OFF: 75 ms.)
60 mm (2.36 in.) diameter pole
*3
Long-range detection
From approx. 450 +/- 50 to 600 +/- 60 mm (17.72 +/- 1.97 to 23.62 +/- 2.36 in.)
Buzzer: Sounds intermittently (ON: 150 ms. / OFF: 150 ms.)
60 mm (2.36 in.) diameter pole
*4
Maximum long-range detection
From approx. 600 +/- 60 to 1500 +/- 150 mm (23.62 +/- 2.36 to 59.06 +/- 5.91 in.)
Buzzer: Sounds intermittently (ON: 150 ms. / OFF: 650 ms.)
Wall
- HINT:
- Ultrasonic waves are used to measure the detection range; however, the detection range may vary depending on the ambient temperature.