2006-2011 Camry Aurion · Service Manual TRANSMISSION

P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)

Diagnostic trouble codes · Vehicles built from Oct 2006

DESCRIPTION

The amount of current flow to the solenoid is controlled by the (*) duty ratio of the TCM output signal. The higher the duty ratio becomes, the higher the lock-up hydraulic pressure becomes during the lock-up operation.
C133227E01
(*) Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle. For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then Duty Ratio = A/(A + B) x 100 (%).
DTC No.
DTC Detection Condition
Trouble Area
P2759
Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1-trip detection logic).
  1. Open or short in shift solenoid valve SLU circuit
  2. Shift solenoid valve SLU
  3. TCM

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve (SLU) circuit is detected, the TCM determines there is a malfunction. The TCM will turn on the MIL and store this DTC.

WIRING DIAGRAM

C133261E12

INSPECTION PROCEDURE


1. INSPECT TRANSMISSION WIRE (SLU)

  1. C133212E07
    Remove the TCM from the transaxle.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    11 (SLU+) - 5 (SLU-)
    5.0 to 5.6 Ω
    (at 20°C (68°F))

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Check for short:
    Tester Connection
    Specified Condition
    11 (SLU+) - Body ground
    10 kΩ or higher
    5 (SLU-) - Body ground
    10 kΩ or higher



OK
REPLACE TCM
NG


2. INSPECT SHIFT SOLENOID VALVE SLU

  1. G020767E09
    Remove the shift solenoid valve SLU.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 - 2
    5.0 to 5.6 Ω
    (at 20°C (68°F))

  1. Connect a positive (+) lead through a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes an operating sound.



NG
REPLACE SHIFT SOLENOID VALVE SLU
OK

REPLACE TRANSMISSION WIRE


← P2757 Torque Converter Clutch Pressure Control Solenoid Performance (Shift Solenoid Valve SLU) (from Jun 2009)P2769 Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) (+ P2770) (from Oct 2006) →