B2416 Height Control Sensor Malfunction
Diagnostic trouble codes · Vehicles built from Oct 2006
DESCRIPTION
The AFS ECU receives signals indicating the height of the vehicle from the rear height control sensor.| DTC No. |
DTC Detecting Condition |
Trouble Area |
| B2416 |
|
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch on.
Select the items below in the DATA LIST, and read the display on the intelligent tester.
AFS ECU: Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Rr Height Sens
Rear height control sensor signal value / 0 to 5 V
Approx. 2.5 V
-
Height Sens Val
Rear height control sensor power supply value / 0 to 5 V
Approx. 5.0 V
-
- OK:
- Normal conditions listed above are displayed.
|
|
||||
| NG | |
| 2. CHECK HARNESS AND CONNECTOR (AFS ECU - REAR HEIGHT CONTROL SENSOR SUB-ASSEMBLY) |
Disconnect the A61 AFS ECU connector.

Disconnect the O23 rear height control sensor sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A61-18 (A6M) - O23-3 (SHB)
Always
Below 1 Ω
A61-19 (A6E) - O23-2 (SHRR)
Always
Below 1 Ω
A61-21 (A6N) - O23-1 (SHG)
Always
Below 1 Ω
A61-18 (A6M) - Body ground
Always
10 kΩ or higher
A61-19 (A6E) - Body ground
Always
10 kΩ or higher
A61-21 (A6N) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 3. INSPECT AFS ECU |
Reconnect the A61 AFS ECU connector.

Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Condition
Condition
Specified Condition
A61-18 (A6M) - A61-21 (A6N)
Ignition switch on (IG)
4.5 to 5.5 V
|
|
||||
| OK | |
| 4. INSPECT REAR HEIGHT CONTROL SENSOR SUB-ASSEMBLY |
Connect 3 dry cell batteries (1.5 V) in series.

Remove the rear height control sensor sub-assembly.
Connect the positive (+) lead from the battery to terminal 3, and the negative (-) lead from the battery to terminal 1.
Measure the voltage between terminals 2 and 1 while slowly moving the link up and down.
- Standard voltage:
Tester Condition
Condition
Specified Condition
2 (SHRR) - 1 (SHG)
+45°(High)
Approx. 4.05 V
0°(Normal)
Approx. 2.25 V
-45°(Low)
Approx. 0.45 V
|
|
||||
| OK | ||
| ||