P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
Diagnostic trouble codes · Vehicles built from Jun 2006
DESCRIPTION
The shift solenoid valve (SLT) controls the transmission line pressure for smooth transmission operation based on signals from the throttle position sensor and the vehicle speed sensor. The ECM adjusts the duty cycle of the SLT solenoid valve to control hydraulic line pressure coming from the primary regulator valve. Appropriate line pressure assures smooth shifting with varying engine outputs.(*): Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle.
For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then
Duty Ratio=A/(A + B) x 100(%)
| DTC No. |
DTC Detection Condition |
Trouble Area |
| P2716 |
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detecting logic). |
|


MONITOR DESCRIPTION
When an open or short in the shift solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SLT) |
Disconnect the transmission wire connector from the transaxle.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
2 (SLT+) - 8 (SLT-)
5.0 to 5.6 Ω
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for short):
Tester Connection
Specified Condition
2 (SLT+) - Body ground
10 kΩ or higher
8 (SLT-) - Body ground
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
Connect the transmission wire connector to the transaxle.

Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
C24-76 (SLT+) - C24-75 (SLT-)
5.0 to 5.6 Ω
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for short):
Tester Connection
Specified Condition
C24-76 (SLT+) - Body ground
10 kΩ or higher
C24-75 (SLT-) - Body ground
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE (SLT) |
Remove the shift solenoid valve (SLT).

Measure the resistance according to the value(s) in the table below.
- Standard resistance :
Tester Connection
Specified Condition
20°C (68°F)
1 - 2
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid makes an operating sound.
|
|
||||
| OK | ||
| ||