2006-2011 Camry Aurion · Service Manual ENGINE

INSPECTION

Inspection · Vehicles built from Oct 2006


INSPECT INTAKE AIR CONTROL VALVE

  1. Inspection procedure when applying voltage between the terminals:

    1. Disconnect the connector from the intake air control valve.

    2. A142732
      Apply battery voltage between terminals 1 (-) and 2 (+) of the intake air control valve. Check that a clicking sound is heard from the intake air control valve.
      If the result is not as specified, replace the intake air surge tank.


INSPECT AIR CLEANER ASSEMBLY

  1. A129503
    Apply 26.6 kPa (200 mmHg, 7.9 in. Hg) of vacuum to the actuator. Check if the valve rotates open, as shown in the illustration.

  1. Apply vacuum for 1 minute. The actuator should continue to keep the valve open.
    If the result is not as specified, replace the air cleaner assembly.

← ON-VEHICLE INSPECTION (from Oct 2006)COMPONENTS (from Jun 2006) →