B1411/11 Room Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built from Oct 2006
Versions by build date: Jun 2006 – Sep 2006 from Oct 2006
DESCRIPTION
This sensor detects the cabin temperature that is used as the basis for temperature control and sends a signal to the A/C amplifier.| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1411/11 |
Room temperature sensor circuit (Open or short) |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch on.
Select the item below in the Data List, and read the display on the intelligent tester.
Data List / Air Conditioner: Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Room Temperature Sensor
(Room Temp)
Room temperature sensor / min.: -6.5°C (20.3°F), max.: 57.25°C (135.05°F)
Actual cabin temperature is displayed
-
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
Proceed to
NG
A
OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
B
OK (When troubleshooting according to the DTC)
C
|
|
||||
|
|
||||
| A | |
| 2. INSPECT AIR CONDITIONING AMPLIFIER |
Remove the A/C amplifier with the connectors still connected.

Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
E38-29 (TR) - E38-34 (SG-1)
Ignition switch on (IG) at 25°C (77°F)
1.35 to 1.75 V
E38-29 (TR) - E38-34 (SG-1)
Ignition switch on (IG) at 40°C (104°F)
0.9 to 1.2 V
- HINT:
- As the temperature increases, the voltage decreases.
- Result:
Result
Proceed to
NG
A
OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
B
OK (When troubleshooting according to the DTC)
C
|
|
||||
|
|
||||
| A | |
| 3. INSPECT A/C ROOM TEMPERATURE SENSOR |
Remove the A/C room temperature sensor.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
E27-1 - E27-2
10°C (50°F)
3.00 to 3.73 kΩ
E27-1 - E27-2
15°C (59°F)
2.45 to 2.88 kΩ
E27-1 - E27-2
20°C (68°F)
1.95 to 2.30 kΩ
E27-1 - E27-2
25°C (77°F)
1.60 to 1.80 kΩ
E27-1 - E27-2
30°C (86°F)
1.28 to 1.47 kΩ
E27-1 - E27-2
35°C (95°F)
1.00 to 1.22 kΩ
E27-1 - E27-2
40°C (104°F)
0.80 to 1.00 kΩ
E27-1 - E27-2
45°C (113°F)
0.65 to 0.85 kΩ
E27-1 - E27-2
50°C (122°F)
0.50 to 0.70 kΩ
E27-1 - E27-2
55°C (131°F)
0.44 to 0.60 kΩ
E27-1 - E27-2
60°C (140°F)
0.36 to 0.50 kΩ
- NOTICE:
- Hold the sensor only by its connector. Touching the sensor may change the resistance value.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Hold the sensor only by its connector. Touching the sensor may change the resistance value.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR (A/C ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
Disconnect the connector from the A/C amplifier.

Disconnect the connector from the A/C room temperature sensor.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
E38-29 (TR) - E27-1
Always
Below 1 Ω
E38-34 (SG-1) - E27-2
Always
Below 1 Ω
E38-29 (TR) - Body ground
Always
10 kΩ or higher
E38-34 (SG-1) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||
