2006-2011 Camry Aurion · Service Manual HEATER & AIR CONDITIONING SYSTEM

B1411/11 Room Temperature Sensor Circuit

Diagnostic trouble codes · Vehicles built from Oct 2006

Versions by build date: Jun 2006 – Sep 2006 from Oct 2006

DESCRIPTION

This sensor detects the cabin temperature that is used as the basis for temperature control and sends a signal to the A/C amplifier.
DTC No.
DTC Detection Condition
Trouble Area
B1411/11
Room temperature sensor circuit (Open or short)
  1. A/C room temperature sensor
  2. Harness or connector between A/C room temperature sensor and A/C amplifier
  3. A/C amplifier

WIRING DIAGRAM

I008282E06

INSPECTION PROCEDURE


1. READ VALUE USING INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and turn the intelligent tester main switch on.

  1. Select the item below in the Data List, and read the display on the intelligent tester.

    Data List / Air Conditioner: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temperature Sensor
    (Room Temp)
    Room temperature sensor / min.: -6.5°C (20.3°F), max.: 57.25°C (135.05°F)
    Actual cabin temperature is displayed
    -

    OK:
    The display is as specified in the normal condition column.


    Result:
    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


2. INSPECT AIR CONDITIONING AMPLIFIER

  1. E124471E02
    Remove the A/C amplifier with the connectors still connected.

  1. Turn the ignition switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    E38-29 (TR) - E38-34 (SG-1)
    Ignition switch on (IG) at 25°C (77°F)
    1.35 to 1.75 V
    E38-29 (TR) - E38-34 (SG-1)
    Ignition switch on (IG) at 40°C (104°F)
    0.9 to 1.2 V

    HINT:
    As the temperature increases, the voltage decreases.

    Result:
    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


3. INSPECT A/C ROOM TEMPERATURE SENSOR

  1. E110805E04
    Remove the A/C room temperature sensor.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    E27-1 - E27-2
    10°C (50°F)
    3.00 to 3.73 kΩ
    E27-1 - E27-2
    15°C (59°F)
    2.45 to 2.88 kΩ
    E27-1 - E27-2
    20°C (68°F)
    1.95 to 2.30 kΩ
    E27-1 - E27-2
    25°C (77°F)
    1.60 to 1.80 kΩ
    E27-1 - E27-2
    30°C (86°F)
    1.28 to 1.47 kΩ
    E27-1 - E27-2
    35°C (95°F)
    1.00 to 1.22 kΩ
    E27-1 - E27-2
    40°C (104°F)
    0.80 to 1.00 kΩ
    E27-1 - E27-2
    45°C (113°F)
    0.65 to 0.85 kΩ
    E27-1 - E27-2
    50°C (122°F)
    0.50 to 0.70 kΩ
    E27-1 - E27-2
    55°C (131°F)
    0.44 to 0.60 kΩ
    E27-1 - E27-2
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Hold the sensor only by its connector. Touching the sensor may change the resistance value.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).



NG
REPLACE A/C ROOM TEMPERATURE SENSOR
OK


4. CHECK HARNESS AND CONNECTOR (A/C ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)

  1. E124470E29
    Disconnect the connector from the A/C amplifier.

  1. E124472E02
    Disconnect the connector from the A/C room temperature sensor.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    E38-29 (TR) - E27-1
    Always
    Below 1 Ω
    E38-34 (SG-1) - E27-2
    Always
    Below 1 Ω
    E38-29 (TR) - Body ground
    Always
    10 kΩ or higher
    E38-34 (SG-1) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER


← B1411/11 Room Temperature Sensor Circuit (Jun 2006 – Sep 2006)B1412/12 Ambient Temperature Sensor Circuit (Jun 2006 – Sep 2006) →