2006-2011 Camry Aurion · Service Manual HEATER & AIR CONDITIONING SYSTEM

SYSTEM DESCRIPTION

Troubleshooting · Vehicles built Jun 2006 – Sep 2006

Versions by build date: Jun 2006 – Sep 2006 from Oct 2006


GENERAL
The air conditioning system has the following controls:
Control
Outline
Manual A/C
Automatic A/C
Neural Network Control
This control is capable of effecting complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input/output relationship that is similar to a human brain.
-
○
Manual Control
The A/C amplifier controls the damper positions (air inlet control damper, air mix control damper and mode control damper) and blower speed in accordance with the positions of the switches (temperature control switch, blower switch, mode select switch and air inlet control switch).
○
-
Outlet Air Temp. Control
Based on the temperature set at the temperature control switch, the neural network control calculates the outlet air temperature based on the input signals from various sensors.
-
○
The temperature setting for the driver and front passenger are controlled independently in order to provide a separate vehicle interior temperatures for the right and left side of the cabin. Thus, air conditioning that accommodates the occupants' preferences has been realized.
-
○
Blower Control
Controls the blower motor in accordance with the airflow volume that has been calculated by the neural network control based on the input signals from various sensors.
-
○
Air Outlet Control
Automatically switches the air outlets in accordance with the outlet mode that has been calculated by the neural network control based on the input signals from various sensors.
-
○
In accordance with the engine coolant temperature, outside air temperature, amount of sunlight, required blower, outlet temperature, and vehicle speed conditions, this control automatically switches the blower outlet to the FOOT / DEF mode to prevent the windows from becoming fogged when the outside air temperature is low.
-
○
Air Inlet Control
Automatically controls the air inlet control damper to achieve the calculated required outlet air temperature.
-
○
Drives the servo motor (for air inlet) according to the operation of the air inlet control switch and moves the dampers to the FRESH or RECIRC position.
-
○
Compressor Control
Through the calculation of the target evaporator temperature based on various sensor signals, the A/C amplifier optimally controls the discharge capacity by regulating the opening extent of the A/C compressor solenoid valve.
○
○
Rear Window Defogger Control
Switch the rear defogger on for 15 minutes when the rear defogger button is pressed. Switches them off if the button is pressed while they are operating.
○
○
Outside Temperature Indication Control
Calculates the outside temperature using signals transmitted by the outside temperature sensor. Calculated values are corrected by the A/C amplifier and then indicated on the multi-information display.
○
○
Self-Diagnosis
A DTC (Diagnostic Trouble Code) is stored in the memory when the A/C amplifier detects a problem with the air conditioning system.
○
○

NEURAL NETWORK CONTROL
  1. In previous automatic air conditioning systems, the A/C amplifier determined the required outlet air temperature and blower air volume in accordance with the calculation formula that has been obtained based on information received from the sensors.
    However, because the senses of a person are rather complex, a given temperature is sensed differently, depending on the environment in which the person is situated. For example, a given amount of solar radiation can feel comfortably warm in a cold climate, or extremely uncomfortable in a hot climate. Therefore, as a technique for effecting a higher level of control, a neural network has been adopted in the automatic air conditioning system. With this technique, the data that has been collected under varying environmental conditions is stored in the A/C amplifier. The A/C amplifier can then effect control to provide enhanced air conditioning comfort.
  2. The neural network control consists of neurons in the input layer, intermediate layer, and output layer. The input layer neurons process the input data of the outside temperature, the amount of sunlight, and the room temperature based on the outputs of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of these is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume, and outlet mode control volume. Accordingly, the A/C amplifier controls the servo motors and blower motor in accordance with the control volumes that have been calculated by the neural network control.
E116942E01

MODE POSITION AND DAMPER OPERATION

  1. Mode Position and Damper Operation (for Manual A/C)
    E138247E03

    Functions of Main Dampers: 
    Control Damper
    Operation Position
    Damper Position
    Operation
    Air Inlet Control Damper
    FRESH
    A
    Brings in fresh air.
    RECIRC
    B
    Recirculates internal air.
    Air Mix Control Damper
    MAX COLD to MAX HOT Temperature Setting
    C - D - E
    T - U - V
    Varies the mixture ratio of the fresh air and the recirculation air in order to regulate the temperature continuously from HOT to COLD.
    Air Outlet Control Damper
    DEF
    E106660
    F, J, L, P, S, Y
    Defrosts the windshield through the center defroster, side defroster, side register, and rear register.
    FOOT / DEF
    E106659
    G, J, L, P, Q, X
    Defrosts the windshield through the center defroster, side defroster, side register, and rear register, while air is also blown out from the front and rear foot well register ducts.
    FOOT
    E106658
    H, J, L, P, Q, X
    Air blows out of the foot well register duct and side register. In addition, air blows out slightly from the center defroster and side defroster.
    BI-LEVEL
    E106657
    I, K, N, O, R, X
    Air blows out of the front center register, side register and front and rear foot well register ducts.
    FACE
    E106656
    I, K, M, O, S, W
    Air blows out of the front center register and side register.

  2. Mode Position and Damper Operation (for Automatic A/C)
    C118756E05

    Functions of Main Dampers: 
    Control Damper
    Operation Position
    Damper Position
    Operation
    Air Inlet Control Damper
    FRESH
    A
    Brings in fresh air.
    RECIRC
    B
    Recirculates internal air.
    Air Mix Control Damper
    MAX COLD to MAX HOT Temperature Setting
    C - D - E
    (C' - D' - E')
    T - U - V
    Varies the mixture ratio of the fresh air and the recirculation air in order to regulate the temperature continuously from HOT to COLD.
    Air Outlet Control Damper
    DEF
    E106660
    F, J, L, P, S, Y
    Defrosts the windshield through the center defroster, side defroster, and side register.
    FOOT / DEF
    E106659
    G, J, L, P, Q, X
    Defrosts the windshield through the center defroster, side defroster, side register, and rear center register, while air is also blown out from the front and rear foot well register ducts.
    FOOT
    E106658
    H, J, L, P, Q, X
    Air blows out of the foot well register dust, and side register. In addition, air blows out slightly from the center defroster and side defroster.
    BI-LEVEL
    E106657
    I, K, N, O, R, X
    Air blows out of the front and rear center registers, side register and front and rear foot well register ducts.
    FACE
    E106656
    I, K, M, O, S, W
    Air blows out of the front and rear center registers, and side register.


AIR OUTLETS AND AIRFLOW VOLUME

  1. Air Outlets and Airflow Volume
    E133944E02

    INDICATION
    (MODE)
    SELECTION
    (Auto / Manual)
    FACE
    FOOT
    DEF
    CTR
    SIDE
    RR
    FR
    RR
    CTR
    SIDE
    A
    B
    C*6
    D
    E
    F
    G
    E106656
    FACE
    ○ / ○
    E107019
    E107019
    E107019
    E107318
    E107318
    E107318
    E107318
    E106657
    B/L-U*1
    ○ / ○
    E107020
    E107020
    E107020
    E107021
    E107021
    E107318
    E107318
    E106657
    B/L-L*2
    ○ / -
    E107021
    E107021
    E107021
    E107020
    E107020
    E107318
    E107318
    E106658
    FOOT-F*3
    ○ / -
    E107318
    E107021
    E107021
    E107020
    E107021
    E107317
    E107317
    E106658
    FOOT-R*4
    ○ / ○
    E107318
    E107021
    E107021
    E107020
    E107020
    E107317
    E107317
    E106658
    FOOT-D*5
    ○ / -
    E107318
    E107021
    E107021
    E107021
    E107021
    E107021
    E107021
    E106659
    F/D
    ○ / ○
    E107318
    E107021
    E107021
    E107020
    E107020
    E107020
    E107020
    E106660
    DEF
    ○ / ○
    E107318
    E107021
    E107318
    E107318
    E107318
    E107019
    E107019
    The size of the circle ○ indicates the proportion of airflow volume.
    *1: Greater airflow volume at the upper area
    *2: Greater airflow volume at the lower area
    *3: Greater airflow volume at the front
    *4: Greater airflow volume at the rear
    *5: Greater airflow volume at the defroster
    *6: Only for models with automatic air conditioning.


BLOWER MOTOR
The blower motor has a built-in blower controller, and is controlled with duty control from the A/C amplifier.

BUS CONNECTOR

  1. A BUS connector is used in the wire harness connection that connects the servo motor from the A/C amplifier.
    E116948E01

  2. The BUS connector has a built-in communication/driver IC which communicates with each servo motor connector, actuates the servo motor, and has a position detection function. This enables bus communication for the servo motor wire harness, for a more lightweight construction and a reduced number of wires.
    E116949E01


SERVO MOTOR

  1. The pulse pattern type servo motor consists of a printed circuit board and servo motor. The printed circuit board has three contact points, and transmits to the A/C amplifier two ON-OFF signals for the difference of the pulse phase. The BUS connector detects the damper position and movement direction with this signal.
    E116950E01


A/C COMPRESSOR
  1. General

    1. The A/C compressor is a continuously variable capacity type in which its capacity can be varied in accordance with the cooling load of the air conditioning.

    2. This compressor consists of the A/C pulley, shaft, lug plate, swash plate, piston, shoe, crank chamber, cylinder, and solenoid valve.

    3. The DL (Damper Limiter) type A/C pulley is installed.

    4. A solenoid valve that adjusts the suction pressure so that the compressor capacity can be controlled as desired is provided.

    5. The internal valve is provided to improve the A/C compressor durability under the high speed and large thermal load conditions. The internal valve is integrated into the solenoid valve.

  2. Solenoid Valve Operation

    1. The crank chamber is connected to the discharge passage. A solenoid valve is provided between the discharge passage (LO pressure) and the discharge passage (HI pressure).

    2. The solenoid valve operates under duty cycle control in accordance with the signals from A/C amplifier.

    3. When the solenoid valve closes (solenoid coil is energized), a difference in pressure is created and the pressure in the crank chamber decreases. Then, the pressure that is applied to the right side of the piston becomes greater than the pressure that is applied to the left side of the piston. This compresses the spring and tilts the swash plate. As a result, the piston stroke increases and the discharge capacity increases.

    4. When the solenoid valve opens (solenoid coil is not energized), the difference in pressure disappears. Then, the pressure that is applied to the left side of the piston becomes the same as the pressure that is applied to the right side of the piston. Thus, the spring elongates and eliminates the tilt of the swash plate. As a result, there is no piston stroke and the discharge capacity is reduced.

  3. Internal Valve Operation

    1. The internal valve operates when the A/C compressor speed has increased rapidly, the A/C compressor speed is high, or when thermal load has suddenly changed. As a result, the A/C compressor capacity is reduced, increasing the durability of the A/C compressor.

  4. DL type A/C Pulley

    1. This pulley contains a damper to absorb the torque fluctuations of the engine and a limiter mechanism to protect the drive belt in case the compressor locks. In the event that the compressor locks, the limiter mechanism causes the spoke portion of the pulley to break, thus separating the pulley from the compressor.


ROOM TEMPERATURE SENSOR (for Automatic A/C)
The room temperature sensor detects the cabin temperature based on changes in the resistance of its built-in thermistor and sends a signal to the A/C amplifier.

AMBIENT TEMPERATURE SENSOR
The ambient temperature sensor detects the outside temperature based on changes in the resistance of its built-in thermistor and sends a signal to the A/C amplifier.

SOLAR SENSOR (for Automatic A/C)
  1. The solar sensor consists of a photo diode, two amplifier circuits for the solar sensor, and frequency converter circuit for the light control sensor.

  2. A solar sensor detects (in the form of changes in the current that flows through the built-in photo diode) the changes in the amount of sunlight from the LH and RH sides (2 directions) and outputs these sunlight strength signals to the A/C amplifier.
    E116951E01


EVAPORATOR TEMPERATURE SENSOR
The evaporator temperature sensor detects the temperature of the cool air immediately past the evaporator in the form of resistance changes, and outputs it to the A/C amplifier.

A/C PRESSURE SENSOR
The A/C pressure sensor detects the refrigerant pressure and outputs it to the A/C amplifier in the form of voltage changes.
← SYSTEM DIAGRAM (from Jun 2006)SYSTEM DESCRIPTION (from Oct 2006) →