Interior Light Circuit
Circuit diagnosis · Vehicles built from Oct 2006
DESCRIPTION
The main body ECU controls the illuminated entry system (interior light and ignition key cylinder light).WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch on.
Select the item(s) below in the ACTIVE TEST, and check the operation.
Main Body (Main Body ECU): Tester Display
Test Part
Control Range
Diagnostic Note
Illuminated Entry System
Interior light and ignition key cylinder light (Interior light switch is in DOOR position and all doors are closed).
ON / OFF
-
- OK:
- Each light illuminates.
|
|
||||
| NG | |
| 2. CHECK VEHICLE CONDITION |
Check the vehicle condition.
- Result:
Condition
Proceed to
without Sliding Roof
A
with Sliding Roof
B
|
|
||||
| A | |
| 3. CHECK HARNESS AND CONNECTOR (LIGHT - BATTERY AND INSTRUMENT PANEL J/B ASSEMBLY) |
Disconnect the E25 transponder key amplifier connector (*1).

Disconnect the Q9 rear room light assembly connector.
Disconnect the IR and II instrument panel J/B assembly connectors.
Measure the voltage and resistance according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
E25-2 (ILL+) - Body ground (*1)
Always
10 to 14 V
Q9-1 (B) - Body ground
Always
10 to 14 V
- Standard resistance:
Tester Connection
Condition
Specified Condition
II-10 - E25-6 (ILL-) (*1)
Always
Below 1 Ω
IR-5 - Q9-2 (CTY)
Always
Below 1 Ω
II-10 - Body ground
Always
10 kΩ or higher
IR-5 - Body ground
Always
10 kΩ or higher
- HINT:
- *1: without Smart Entry and Start System
|
|
||||
| OK | ||
| ||
| 4. CHECK HARNESS AND CONNECTOR (LIGHT - BATTERY AND INSTRUMENT PANEL J/B ASSEMBLY) |
Disconnect the E25 transponder key amplifier connector (*1).

Disconnect the Q6 overhead J/B connector.
Disconnect the IR and II instrument panel J/B assembly connectors.
Measure the voltage and resistance according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
E25-2 (ILL+) - Body ground (*1)
Always
10 to 14 V
Q6-7 (B) - Body ground
Always
10 to 14 V
- Standard resistance:
Tester Connection
Condition
Specified Condition
II-10 - E25-6 (ILL-) (*1)
Always
Below 1 Ω
IR-5 - Q6-6 (CTY)
Always
Below 1 Ω
II-10 - Body ground
Always
10 kΩ or higher
IR-5 - Body ground
Always
10 kΩ or higher
- HINT:
- *1: without Smart Entry and Start System
|
|
||||
| OK | ||
| ||