INSPECTION
Inspection · Vehicles built from Oct 2006
| INSPECT ROOM TEMPERATURE SENSOR |
 |
- Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
|
Condition
|
Specified Condition
|
1 - 2
|
10°C (50°F)
|
3.00 to 3.73 kΩ
|
1 - 2
|
15°C (59°F)
|
2.45 to 2.88 kΩ
|
1 - 2
|
20°C (68°F)
|
1.95 to 2.30 kΩ
|
1 - 2
|
25°C (77°F)
|
1.60 to 1.80 kΩ
|
1 - 2
|
30°C (86°F)
|
1.28 to 1.47 kΩ
|
1 - 2
|
35°C (95°F)
|
1.00 to 1.22 kΩ
|
1 - 2
|
40°C (104°F)
|
0.80 to 1.00 kΩ
|
1 - 2
|
45°C (113°F)
|
0.65 to 0.85 kΩ
|
1 - 2
|
50°C (122°F)
|
0.50 to 0.70 kΩ
|
1 - 2
|
55°C (131°F)
|
0.44 to 0.60 kΩ
|
1 - 2
|
60°C (140°F)
|
0.36 to 0.50 kΩ
|
- NOTICE:
- Hold the sensor only by its connector. Touching the sensor may change the resistance value.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
If the resistance is not as specified, replace the room temperature sensor.