2006-2011 Camry Aurion · Service Manual ENGINE

INSTALLATION

Removal / installation · Vehicles built Oct 2006 – May 2009

Versions by build date: Jun 2006 – Sep 2006 Oct 2006 – May 2009 from Jun 2009


1. INSTALL STARTER ASSEMBLY (for Manual Transaxle)

  1. A133566E02
    Install the starter assembly and clutch flexible hose bracket with the 3 bolts.

    Torque:
    Bolt A:
    37 N*m{ 380 kgf*cm , 28 ft.*lbf }
    Bolt B:
    12 N*m{ 120 kgf*cm , 9 ft.*lbf }

  1. A133565
    Connect the wire harness to terminal 30 and install the nut. Then, attach the terminal cap.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }

  1. Connect the terminal 50 connector to the starter assembly.


2. INSTALL STARTER ASSEMBLY (for Automatic Transaxle)

  1. A134877
    Install the starter assembly with the 2 bolts.

    Torque:
    37 N*m{ 380 kgf*cm , 28 ft.*lbf }

  1. A134876
    Connect the wire harness to terminal 30 and install the nut. Then, attach the terminal cap.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }

  1. Connect the terminal 50 connector to the starter assembly.


3. INSTALL AIR CLEANER CASE SUB-ASSEMBLY

  1. A134905
    Install the air cleaner case with the 3 bolts.

    Torque:
    5.0 N*m{ 51 kgf*cm , 44 in.*lbf }

  1. Connect the hose clamp.


4. INSTALL AIR CLEANER CAP SUB-ASSEMBLY
  1. Install the air cleaner filter element onto the air cleaner case.

  1. A135670
    Insert the hinges. Install the air cleaner cap sub-assembly with the 2 bolts.

  1. A236553E01
    Connect the No. 1 air cleaner hose to the throttle body and unfasten the No. 1 air cleaner hose clamp.

    NOTICE:
    1. Match each concave area concavity of the air cleaner hose with the bolt of the throttle body.
    2. Make sure that the hose clamp is at the correct angle.

  1. A146036
    Connect the No. 2 ventilation hose to the air cleaner hose.

  1. A135666E02
    Connect the purge line hose to the clamp (*1).

  1. Connect the 2 purge VSV vacuum hoses (*2).

  1. Connect the purge VSV connector (*3).

  1. Connect the mass air flow meter connector (*4).


5. INSTALL AIR CLEANER INLET ASSEMBLY

  1. A134903
    Install the air cleaner inlet with the 2 bolts.

    Torque:
    5.0 N*m{ 51 kgf*cm , 44 in.*lbf }


6. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

Torque:
6.9 N*m{ 70 kgf*cm , 61 in.*lbf }

← INSTALLATION (Jun 2006 – Sep 2006)INSTALLATION (from Jun 2009) →