2006-2011 Camry Aurion · Service Manual TRANSMISSION

INSPECTION

Inspection · Vehicles built from Oct 2006


INSPECT SHIFT SOLENOID VALVE SL

  1. C133217
    Measure the resistance according to the value(s) in the table below.
    Standard resistance 
    Tester Connection
    Specified Condition
    20°C (68°F)
    Solenoid Connector (SL) - Solenoid Body (SL)
    11 to 15 Ω
    If the value is not as specified, replace the shift solenoid valve.

  1. C133218
    Connect the positive (+) lead to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

    OK:
    The solenoid makes an operating noise.

    If the operation cannot be done as specified, replace the shift solenoid valve.


INSPECT SHIFT SOLENOID VALVE SLT

  1. G020767E08
    Measure the resistance according to the value(s) in the table below.
    Standard resistance 
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

    OK:
    The solenoid makes an operating noise.

    If the operation cannot be done as specified, replace the shift solenoid valve.


INSPECT SHIFT SOLENOID VALVE SLU

  1. G020767E09
    Measure the resistance according to the value(s) in the table below.
    Standard resistance 
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

    OK:
    The solenoid makes an operating noise.

    If the operation cannot be done as specified, replace the shift solenoid valve.


INSPECT SHIFT SOLENOID VALVE SL2

  1. G020767E07
    Measure the resistance according to the value(s) in the table below.
    Standard resistance 
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

    OK:
    The solenoid makes an operating noise.

    If the operation cannot be done as specified, replace the shift solenoid valve.


INSPECT SHIFT SOLENOID VALVE SL1

  1. G020767E05
    Measure the resistance according to the value(s) in the table below.
    Standard resistance 
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

    OK:
    The solenoid makes an operating noise.

    If the operation cannot be done as specified, replace the shift solenoid valve.


INSPECT SHIFT SOLENOID VALVE SL3

  1. G020767E29
    Measure the resistance according to the value(s) in the table below.
    Standard resistance 
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

    OK:
    The solenoid makes an operating noise.

    If the operation cannot be done as specified, replace the shift solenoid valve.


INSPECT SHIFT SOLENOID VALVE SL4

  1. G020767E50
    Measure the resistance according to the value(s) in the table below.
    Standard resistance 
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

    OK:
    The solenoid makes an operating noise.

    If the operation cannot be done as specified, replace the shift solenoid valve.

← DISASSEMBLY (from Oct 2006)REASSEMBLY (from Oct 2006) →