B1412/12 Ambient Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built Jun 2006 – Sep 2006
Versions by build date: Jun 2006 – Sep 2006 from Oct 2006
DESCRIPTION
The ambient temperature sensor is installed in front of the condenser to detect the ambient temperature. This sensor is connected to the A/C amplifier and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the A/C amplifier. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The A/C amplifier applies voltage (5 V) to the ambient temperature sensor and reads voltage changes as the resistance of the ambient temperature sensor changes.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1412/12 |
Open or short in ambient temperature sensor circuit |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position and turn the intelligent tester main switch on.
Select the item below in the Data List, and read the display on the intelligent tester.
| Tester Display |
Measurement Item/Range |
Normal Condition |
Diagnostic Note |
| Ambient Temp Sensor (Ambi Temp Sens) |
Ambient temperature sensor / Min: -23.3°C (-9.94°F), Max: 65.95°C (150.71°F) |
Actual ambient temperature is displayed |
Open in circuit: -23.3°C (-9.94°F) Short in circuit: 65.95°C (150.71°F) |
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
Proceed to
NG
A
OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
B
OK (When troubleshooting according to the DTC)
C
|
|
||||
|
|
||||
| A | |
| 2. INSPECT AIR CONDITIONING AMPLIFIER |
Remove the A/C amplifier with the connectors still connected.

Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
E38-5 (TAM) - E38-13 (SG-2)
Ignition switch: ON
at 25°C (77°F)
1.35 to 1.75 V
E38-5 (TAM) - E38-13 (SG-2)
Ignition switch: ON
at 40°C (104°F)
0.9 to 1.2 V
- HINT:
- As the temperature increases, the voltage decreases.
- Result:
Result
Proceed to
NG
A
OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
B
OK (When troubleshooting according to the DTC)
C
|
|
||||
|
|
||||
| A | |
| 3. INSPECT AMBIENT TEMPERATURE SENSOR |
Remove the ambient temperature sensor.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A2-1 - A2-2
10°C (50°F)
3.00 to 3.73 kΩ
A2-1 - A2-2
15°C (59°F)
2.45 to 2.88 kΩ
A2-1 - A2-2
20°C (68°F)
1.95 to 2.30 kΩ
A2-1 - A2-2
25°C (77°F)
1.60 to 1.80 kΩ
A2-1 - A2-2
30°C (86°F)
1.28 to 1.47 kΩ
A2-1 - A2-2
35°C (95°F)
1.00 to 1.22 kΩ
A2-1 - A2-2
40°C (104°F)
0.80 to 1.00 kΩ
A2-1 - A2-2
45°C (113°F)
0.65 to 0.85 kΩ
A2-1 - A2-2
50°C (122°F)
0.50 to 0.70 kΩ
A2-1 - A2-2
55°C (131°F)
0.44 to 0.60 kΩ
A2-1 - A2-2
60°C (140°F)
0.36 to 0.50 kΩ
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - A/C AMPLIFIER) |
Disconnect the ambient temperature sensor connector.

Disconnect the A/C amplifier connector.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A2-2 - E38-5 (TAM)
Always
Below 1 Ω
A2-1 - E38-13 (SG-2)
Always
Below 1 Ω
E38-5 (TAM) - Body ground
Always
10 kΩ or higher
E38-13 (SG-2) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||