2006-2011 Camry Aurion · Service Manual HEATER & AIR CONDITIONING SYSTEM

B1412/12 Ambient Temperature Sensor Circuit

Diagnostic trouble codes · Vehicles built Jun 2006 – Sep 2006

Versions by build date: Jun 2006 – Sep 2006 from Oct 2006

DESCRIPTION

The ambient temperature sensor is installed in front of the condenser to detect the ambient temperature. This sensor is connected to the A/C amplifier and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the A/C amplifier. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The A/C amplifier applies voltage (5 V) to the ambient temperature sensor and reads voltage changes as the resistance of the ambient temperature sensor changes.
DTC No.
DTC Detection Condition
Trouble Area
B1412/12
Open or short in ambient temperature sensor circuit
  1. Ambient temperature sensor
  2. Harness or connector between ambient temperature sensor and A/C amplifier
  3. A/C amplifier

WIRING DIAGRAM

I008282E07

INSPECTION PROCEDURE


1. READ VALUE USING INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to the ON position and turn the intelligent tester main switch on.

  1. Select the item below in the Data List, and read the display on the intelligent tester.

Data List / Air Conditioner: 
Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Ambient Temp Sensor
(Ambi Temp Sens)
Ambient temperature sensor / Min: -23.3°C (-9.94°F), Max: 65.95°C (150.71°F)
Actual ambient temperature is displayed
Open in circuit: -23.3°C (-9.94°F)
Short in circuit: 65.95°C (150.71°F)

OK:
The display is as specified in the normal condition column.


Result:
Result
Proceed to
NG
A
OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
B
OK (When troubleshooting according to the DTC)
C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


2. INSPECT AIR CONDITIONING AMPLIFIER

  1. E124471E15
    Remove the A/C amplifier with the connectors still connected.

  1. Turn the ignition switch to the ON position.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    E38-5 (TAM) - E38-13 (SG-2)
    Ignition switch: ON
    at 25°C (77°F)
    1.35 to 1.75 V
    E38-5 (TAM) - E38-13 (SG-2)
    Ignition switch: ON
    at 40°C (104°F)
    0.9 to 1.2 V

    HINT:
    As the temperature increases, the voltage decreases.

    Result:
    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


3. INSPECT AMBIENT TEMPERATURE SENSOR

  1. E118395E04
    Remove the ambient temperature sensor.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A2-1 - A2-2
    10°C (50°F)
    3.00 to 3.73 kΩ
    A2-1 - A2-2
    15°C (59°F)
    2.45 to 2.88 kΩ
    A2-1 - A2-2
    20°C (68°F)
    1.95 to 2.30 kΩ
    A2-1 - A2-2
    25°C (77°F)
    1.60 to 1.80 kΩ
    A2-1 - A2-2
    30°C (86°F)
    1.28 to 1.47 kΩ
    A2-1 - A2-2
    35°C (95°F)
    1.00 to 1.22 kΩ
    A2-1 - A2-2
    40°C (104°F)
    0.80 to 1.00 kΩ
    A2-1 - A2-2
    45°C (113°F)
    0.65 to 0.85 kΩ
    A2-1 - A2-2
    50°C (122°F)
    0.50 to 0.70 kΩ
    A2-1 - A2-2
    55°C (131°F)
    0.44 to 0.60 kΩ
    A2-1 - A2-2
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).



NG
REPLACE AMBIENT TEMPERATURE SENSOR
OK


4. CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - A/C AMPLIFIER)

  1. E124473E02
    Disconnect the ambient temperature sensor connector.

  1. E124470E03
    Disconnect the A/C amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A2-2 - E38-5 (TAM)
    Always
    Below 1 Ω
    A2-1 - E38-13 (SG-2)
    Always
    Below 1 Ω
    E38-5 (TAM) - Body ground
    Always
    10 kΩ or higher
    E38-13 (SG-2) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER


← B1411/11 Room Temperature Sensor Circuit (from Oct 2006)B1412/12 Ambient Temperature Sensor Circuit (from Oct 2006) →