P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)
Diagnostic trouble codes · Vehicles built from Oct 2006
DESCRIPTION
Shifting from 1st to 6th is performed in combination with "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, SL3, SL4 and SL which is controlled by the TCM. If an open or short circuit occurs in any of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (Click here).| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0778 |
The TCM checks for an open or short in the shift solenoid valve SL2 circuit while driving and shifting gears. (1-trip detection logic)
|
|
MONITOR DESCRIPTION
This DTC indicates an open or short in the shift solenoid valve SL2 circuit. The TCM commands gear shifts by turning the shift solenoid valves on or off. When there is an open or short circuit in any of the shift solenoid valve circuits, the TCM detects the problem, illuminates the MIL and stores the DTC. The TCM also performs the fail-safe function and turns the other normal shift solenoid valves on or off. (In case of an open or short circuit, the TCM stops sending current to the circuit.)While driving and shifting gears, if the TCM detects an open or short in the shift solenoid valve SL2 circuit, the TCM determines there is a malfunction (Click here).
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- The shift solenoid valve SL2 is turned on or off automatically when the shift lever is in the D position:
TCM command gearshift
1st
2nd
3rd
4th
5th
6th
Shift solenoid valve SL2
OFF
OFF
OFF
ON
ON
ON
| 1. INSPECT TRANSMISSION WIRE (SL2) |
Remove the TCM from the transaxle.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
9 (SL2+) - 8 (SL2-)
5.0 to 5.6 Ω
(at 20°C (68°F))
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
- Check for short:
Tester Connection
Specified Condition
9 (SL2+) - Body ground
10 kΩ or higher
8 (SL2-) - Body ground
10 kΩ or higher
|
|
||||
| NG | |
| 2. INSPECT SHIFT SOLENOID SL2 |
Remove the shift solenoid valve SL2.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
1 - 2
5.0 to 5.6 Ω
(at 20°C (68°F))
Connect a positive (+) lead through a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid makes an operating sound.
|
|
||||
| OK | ||
| ||
