B1805/52 Short in Front Passenger Side Squib Circuit
Diagnostic trouble codes · Vehicles built Jun 2006 – Sep 2006
Also covers:
- B1806/52 Open in Front Passenger Side Squib Circuit
- B1807/52 Short to GND in Front Passenger Side Squib Circuit
- B1808/52 Short to B+ in Front Passenger Side Squib Circuit
Versions by build date: Jun 2006 – Sep 2006 Oct 2006 – May 2009 from Jun 2009
DESCRIPTION
The front passenger side squib circuit consists of the center airbag sensor assembly and the front passenger airbag assembly.The circuit instructs the SRS to deploy when deployment conditions are met.
These DTCs are recorded when a malfunction is detected in the front passenger side squib circuit.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1805/52 |
|
|
| B1806/52 |
|
|
| B1807/52 |
|
|
| B1808/52 |
|
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- Perform the simulation method by selecting "check mode" (signal check) with the intelligent tester (Click here).
- After selecting "check mode" (signal check), perform the simulation method by wiggling each connector of the airbag system or driving the vehicle on a city or rough road (Click here).
- Perform the simulation method by selecting "check mode" (signal check) with the intelligent tester (Click here).
| 1. CHECK FRONT PASSENGER AIRBAG ASSEMBLY (FRONT PASSENGER SIDE SQUIB) |
Turn the ignition switch to the LOCK position.

Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connectors from the front passenger airbag assembly.
Connect the white wire side of SST (resistance 2.1 Ω) to connector E (orange connector).
- CAUTION:
- Never connect the tester to the front passenger airbag assembly (front passenger side squib) for measurement, as this may lead to a serious injury due to airbag deployment.
- NOTICE:
- Do not forcibly insert the SST into the terminals of the connector when connecting.
- Insert straight the SST into the terminals of the connector.
- Do not forcibly insert the SST into the terminals of the connector when connecting.
- SST
- 09843-18060
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear the DTCs stored in the memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check the DTCs (Click here).
- OK:
- DTC B1805, B1806, B1807, B1808, or 52 is not output.
- HINT:
- Codes other than DTC B1805, B1806, B1807, B1808, and 52 may be output at this time, but they are not related to this check.
|
|
||||
| NG | |
| 2. CHECK CONNECTOR |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the SST from connector E.
Check that the instrument panel wire assembly connectors (on the front passenger airbag assembly side) are not damaged.
- OK:
- The lock button is not disengaged, or the claw of the lock is not deformed or damaged.
|
|
||||
| OK | |
| 3. CHECK FRONT PASSENGER SIDE SQUIB CIRCUIT |
Disconnect the connectors from the center airbag sensor assembly.

Check for a short to B+ in the circuit.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
c2-1 (P+) - Body ground
Ignition switch ON
Below 1 V
c2-2 (P-) - Body ground
Ignition switch ON
Below 1 V
Check for an open in the circuit.
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
c2-1 (P+) - c2-2 (P-)
Always
Below 1 Ω
Check for a short to ground in the circuit.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
c2-1 (P+) - Body ground
Always
1 MΩ or higher
c2-2 (P-) - Body ground
Always
1 MΩ or higher
Check for a short in the circuit.
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
c2-1 (P+) - c2-2 (P-)
Always
1 MΩ or higher
|
|
||||
| OK | |
| 4. CHECK CENTER AIRBAG SENSOR ASSEMBLY |
Connect the connectors to the front passenger airbag assembly and the center airbag sensor assembly.

Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear the DTCs stored in the memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check the DTCs (Click here).
- OK:
- DTC B1805, B1806, B1807, B1808, or 52 is not output.
- HINT:
- Codes other than DTC B1805, B1806, B1807, B1808, and 52 may be output at this time, but they are not related to this check.
|
|
||||
| OK | ||
| ||
| 5. CHECK INSTRUMENT PANEL WIRE |
Restore the released activation prevention mechanism of connector B to the original condition.

Disconnect the instrument panel wire connector from the instrument panel wire assembly.
Check for a short to B+ in the circuit.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
Ec1-1 (P+) - Body ground
Ignition switch ON
Below 1 V
Ec1-2 (P-) - Body ground
Ignition switch ON
Below 1 V
Check for an open in the circuit.
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
Ec1-1 (P+) - Ec1-2 (P-)
Always
Below 1 Ω
Check for a short to ground in the circuit.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
Ec1-1 (P+) - Body ground
Always
1 MΩ or higher
Ec1-2 (P-) - Body ground
Always
1 MΩ or higher
Check for a short in the circuit.
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
Ec1-1 (P+) - Ec1-2 (P-)
Always
1 MΩ or higher
|
|
||||
| OK | |
| 6. CHECK INSTRUMENT PANEL WIRE ASSEMBLY |
Check for a short to B+ in the circuit.

Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
c2-1 (P+) - Body ground
Ignition switch ON
Below 1 V
c2-2 (P-) - Body ground
Ignition switch ON
Below 1 V
Check for an open in the circuit.
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
c2-1 (P+) - c2-2 (P-)
Always
Below 1 Ω
Check for a short to ground in the circuit.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
c2-1 (P+) - Body ground
Always
1 MΩ or higher
c2-2 (P-) - Body ground
Always
1 MΩ or higher
Check for a short in the circuit.
Release the activation prevention mechanism built into connector D (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
c2-1 (P+) - c2-2 (P-)
Always
1 MΩ or higher
|
|
||||
| OK | ||
| ||