2006-2011 Camry Aurion · Service Manual ENGINE

ON-VEHICLE INSPECTION

Inspection · Vehicles built from Oct 2006


COOLING FAN MOTOR

  1. A110241E05
    Check that the motor turns smoothly when the battery is connected to the fan motor connector.

  1. Measure the current while the motor is turning.

    Standard current:
    11.8 to 14.8 A at 20°C (68°F)

    If the result is not as specified, replace the cooling fan motor.


NO. 2 COOLING FAN MOTOR

  1. A110242E05
    Check that the motor turns smoothly when the battery is connected to the fan motor connector.

  1. Measure the current while the motor is turning.

    Standard current:
    11.8 to 14.8 A at 20°C (68°F)

    If the result is not as specified, replace the No. 2 cooling fan motor.

← INSTALLATION (from Jun 2009)ON-VEHICLE INSPECTION (from Oct 2006) →