INSPECTION
Inspection · Vehicles built from Jun 2006
| INSPECT CRANKSHAFT POSITION SENSOR |
 |
- Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Temperature
|
Specified Condition
|
Cold
|
985 to 1,600 Ω
|
Hot
|
1,265 to 1,890 Ω
|
- NOTICE:
- "Cold" and "Hot" mean the temperature of the coils themselves. "Cold" is from -10 to 50°C (14 to 122°F) and "Hot" is from 50 to 100°C (122 to 212°F).
If the resistance is not as specified, replace the sensor.