P0985 Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR)
Diagnostic trouble codes · Vehicles built from Jun 2006
Also covers:
- P0986 Shift Solenoid "E" Control Circuit High (Shift Solenoid Valve SR)
DESCRIPTION
Shifting from 1st to 5th is performed in combination with "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, SL3, S4 and SR which are controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (Fail safe function).| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0985 |
ECM detects short in solenoid valve SR circuit 2 times when solenoid valve SR is operated (1-trip detection logic) |
|
| P0986 |
ECM detects open in solenoid valve SR circuit 2 times when solenoid valve SR is not operated (1-trip detection logic) |
|
MONITOR DESCRIPTION
The ECM commands gear shifts by turning the shift solenoid valves "ON/OFF". When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem and illuminates the MIL and stores the DTC. And the ECM performs the fail-safe function and turns the other normal shift solenoid valves "ON/OFF" (In case of an open or short circuit, the ECM stops sending current to the circuit.)(Click here).
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SR) |
Disconnect the transmission wire connector from the transaxle.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
9 - Body ground
11 to 15 Ω
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
Connect the transmission connector to the transaxle.

Disconnect the connector from the ECM.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
C24-80 (SR) - Body ground
11 to 15 Ω
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE (SR) |
Remove the shift solenoid valve SR.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
Solenoid Connector (SR) - Solenoid Body (SR)
11 to 15 Ω
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
- OK:
- The solenoid makes an operating sound.
|
|
||||
| OK | ||
| ||