ON-VEHICLE INSPECTION
Inspection · Vehicles built Jun 2006 – May 2009
Versions by build date: Jun 2006 – May 2009 from Jun 2009
| INSPECT AUTOMATIC LIGHT CONTROL SENSOR (for Manual Air Conditioning System) |
Disconnect the E11 automatic light control sensor connector.

Measure the voltage and resistance according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
E11-3 (CLTB) - E11-6 (CLTE)
Ignition switch OFF
Below 1 V
Ignition switch ON
10 to 14 V
- Standard resistance:
Tester Connection
Specified Condition
E11-6 (CLTE) - Body ground
Below 1 Ω
Reconnect the automatic light control sensor connector.
Connect an oscilloscope to the automatic light control sensor connector.
Check the waveform.

- OK:
Tester Connection
Tool Setting
Condition
Specified Condition
E11-6 (CLTE) - E11-4 (CLTS)
5 V/DIV., 5 ms./DIV
Ignition switch ON, light control switch in AUTO
Correct waveform is as shown
- HINT:
- If the ambient light becomes brighter, width A becomes narrower.
| INSPECT AUTOMATIC LIGHT CONTROL SENSOR (for Automatic Air Conditioning System) |
Disconnect the E11 automatic light control sensor connector.

Measure the voltage and resistance according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
E11-6 (CLTB) - E11-3 (CLTE)
Ignition switch OFF
Below 1 V
Ignition switch ON
10 to 14 V
- Standard resistance:
Tester Connection
Specified Condition
E11-3 (CLTE) - Body ground
Below 1 Ω
Reconnect the automatic light control sensor connector.
Connect an oscilloscope to the automatic light control sensor connector.
Check the waveform.

- OK:
Tester Connection
Tool Setting
Condition
Specified Condition
E11-3 (CLTE) - E11-5 (CLTS)
5 V/DIV., 5 ms./DIV
Ignition switch ON, light control switch in AUTO
Correct waveform is as shown
- HINT:
- If the ambient light becomes brighter, width A becomes narrower.
