2006-2011 Camry Aurion · Service Manual BODY ELECTRICAL

ON-VEHICLE INSPECTION

Inspection · Vehicles built from Jun 2009

Versions by build date: Oct 2006 – May 2009 from Jun 2009


INSPECT AUTOMATIC LIGHT CONTROL SENSOR (for Manual Air Conditioning System)

  1. E193004E03
    Disconnect the h2 automatic light control sensor connector.

  1. Measure the voltage and resistance according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    h2-3 (CLTB) - h2-5 (CLTE)
    Ignition switch off
    Below 1 V
    Ignition switch on (IG)
    10 to 14 V

    Standard resistance:
    Tester Connection
    Specified Condition
    h2-5 (CLTE) - Body ground
    Below 1 Ω

    If the result is not as specified, there may be a malfunction on the wire harness side.

  1. Reconnect the automatic light control sensor connector.

  1. Connect an oscilloscope to the automatic light control sensor connector.

  1. B113714E01
    Check the waveform.

    OK:
    Tester Connection
    Tool Setting
    Condition
    Specified Condition
    h2-5 (CLTE) - h2-4 (CLTS)
    5 V/DIV., 5 ms./DIV.
    Ignition switch on (IG), light control switch in AUTO
    Correct waveform is as shown

    HINT:
    If the ambient light becomes brighter, width A becomes narrower.

    If the result is not as specified, replace the automatic light control sensor.


INSPECT AUTOMATIC LIGHT CONTROL SENSOR (for Automatic Air Conditioning System)

  1. B109993E37
    Disconnect the h1 automatic light control sensor connector.

  1. Measure the voltage and resistance according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    h1-6 (CLTB) - h1-3 (CLTE)
    Ignition switch off
    Below 1 V
    Ignition switch on (IG)
    10 to 14 V

    Standard resistance:
    Tester Connection
    Specified Condition
    h1-3 (CLTE) - Body ground
    Below 1 Ω

    If the result is not as specified, there may be a malfunction on the wire harness side.

  1. Reconnect the automatic light control sensor connector.

  1. Connect an oscilloscope to the automatic light control sensor connector.

  1. B113714E01
    Check the waveform.

    OK:
    Tester Connection
    Tool Setting
    Condition
    Specified Condition
    h1-3 (CLTE) - h1-5 (CLTS)
    5 V/DIV., 5 ms./DIV.
    Ignition switch on (IG), light control switch in AUTO
    Correct waveform is as shown

    HINT:
    If the ambient light becomes brighter, width A becomes narrower.

    If the result is not as specified, replace the automatic light control sensor.

← ON-VEHICLE INSPECTION (Oct 2006 – May 2009)REMOVAL (Oct 2006 – May 2009) →