ON-VEHICLE CLEANING
Removal / installation · Vehicles built from Oct 2006
| 1. INSPECT FINS BLOCKAGE |
If the fins are clogged, wash them with water or a steam cleaner. Dry with compressed air.

- NOTICE:
- If the distance between the steam cleaner and the core is too close, the fins may become damaged. Keep the following injection distance.
- Standard:
Injection Distance
Injection Pressure
300 mm (11.81 in.)
2942 to 4903 kPa
(30 to 50 kgf/cm2, 427 to 711 psi)
500 mm (19.69 in.)
4903 to 7845 kPa
(50 to 80 kgf/cm2, 711 to 1138 psi)
- If the fins are bent, straighten them with a screwdriver or pliers.
- Never apply water directly onto the electronic components.
- If the distance between the steam cleaner and the core is too close, the fins may become damaged. Keep the following injection distance.
