Room Oscillator Circuit
Circuit diagnosis · Vehicles built from Jun 2009
Versions by build date: Oct 2006 – May 2009 from Jun 2009
DESCRIPTION
The certification ECU activates the electrical key oscillators (console and rear seat). The power is supplied from the certification ECU to both the front and rear cabin oscillators. If the smart entry and start system does not operate properly inside the vehicle, check both the electrical key oscillators (console and rear seat) circuits.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - ELECTRICAL KEY OSCILLATOR) |
Disconnect the E58 ECU connector.

Disconnect the oscillator connectors.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection (Symbols)
Condition
Specified Condition
E58-12 (CG5B) - E56 or E99-3 (CLGB)
Always
Below 1 Ω
E58-11 (CLG5) - E56 or E99-1 (CLG3)
Always
Below 1 Ω
E58-14 (CG6B) - N11 or N49-3 (CLGB)
Always
Below 1 Ω
E58-13 (CLG6) - N11 or N49-1 (CLG4)
Always
Below 1 Ω
E58-12 (CG5B) - Body ground
Always
10 kΩ or higher
E58-11 (CLG5) - Body ground
Always
10 kΩ or higher
E58-14 (CG6B) - Body ground
Always
10 kΩ or higher
E58-13 (CLG6) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 2. CHECK AND REPLACE ELECTRICAL KEY OSCILLATOR |
Replace the electrical key oscillator.
Check that the entry start and lock-in prevention functions operates normally.
- OK:
- Entry start and lock-in prevention functions operates normally.
|
|
||||
| NG | |
| 3. PERFORM ACTIVE TEST USING INTELLIGENT TESTER |
Reconnect the oscillator and the ECU connectors.
Connect the intelligent tester to the DLC3.


Turn the engine switch on (IG).
Following the display on the tester, select "ACTIVE TEST".
Entry and Start (Certification ECU): Tester Display
Test Part
Control Range
Diagnostic Note
Fr Transmitter
Indoor electrical key oscillator (console)
ON/OFF
-
Rr Transmitter
Indoor electrical key oscillator (rear seat)
ON/OFF
-
Measure the frequency according to the value(s) in the table below.

- Standard:
Tester Connection (Symbols)
Condition
Specified Condition
E58-12 (CG5B) - E58-11 (CLG5)
During ACTIVE TEST
Frequency is generated (higher than 0 Hz)
E58-14 (CG6B) - E58-13 (CLG6)
During ACTIVE TEST
Frequency is generated (higher than 0 Hz)
|
|
||||
| OK | ||
| ||