2006-2011 Camry Aurion · Service Manual BODY

INSPECTION

Inspection · Vehicles built from Oct 2006


INSPECT FRONT POWER SEAT SWITCH LH (for LHD)

  1. B105970E08
    Measure the resistance between the specified terminals when each switch is operated.

    Standard resistance (Slide switch):
    Tester Connection
    Switch Condition
    Specified Condition
    U7-1 (B) - U7-9 (SLDF)
    FRONT
    Below 1 Ω
    U7-4 (E) - U7-6 (SLDR)
    FRONT
    Below 1 Ω
    U7-1 (B) - U7-6 (SLDR)
    FRONT
    10 kΩ or higher
    U7-4 (E) - U7-9 (SLDF)
    FRONT
    10 kΩ or higher
    U7-4 (E) - U7-6 (SLDR)
    OFF
    Below 1 Ω
    U7-4 (E) - U7-9 (SLDF)
    OFF
    Below 1 Ω
    U7-1 (B) - U7-6 (SLDR)
    OFF
    10 kΩ or higher
    U7-1 (B) - U7-9 (SLDF)
    OFF
    10 kΩ or higher
    U7-1 (B) - U7-6 (SLDR)
    REAR
    Below 1 Ω
    U7-4 (E) - U7-9 (SLDF)
    REAR
    Below 1 Ω
    U7-1 (B) - U7-9 (SLDF)
    REAR
    10 kΩ or higher
    U7-4 (E) - U7-6 (SLDR)
    REAR
    10 kΩ or higher

    Standard resistance (Front vertical switch):
    Tester Connection
    Switch Condition
    Specified Condition
    U7-1 (B) - U7-10 (FUP)
    UP
    Below 1 Ω
    U7-4 (E) - U7-5 (FDWN)
    UP
    Below 1 Ω
    U7-1 (B) - U7-5 (FDWN)
    UP
    10 kΩ or higher
    U7-4 (E) - U7-10 (FUP)
    UP
    10 kΩ or higher
    U7-4 (E) - U7-5 (FDWN)
    OFF
    Below 1 Ω
    U7-4 (E) - U7-10 (FUP)
    OFF
    Below 1 Ω
    U7-1 (B) - U7- 5 (FDWN)
    OFF
    10 kΩ or higher
    U7-1 (B) - U7-10 (FUP)
    OFF
    10 kΩ or higher
    U7-1 (B) - U7-5 (FDWN)
    DOWN
    Below 1 Ω
    U7-4 (E) - U7-10 (FUP)
    DOWN
    Below 1 Ω
    U7-1 (B) - U7-10 (FUP)
    DOWN
    10 kΩ or higher
    U7-4 (E) - U7-5 (FDWN)
    DOWN
    10 kΩ or higher

    Standard resistance (Lifter switch):
    Tester Connection
    Switch Condition
    Specified Condition
    U7-1 (B) - U7-7 (LUP)
    UP
    Below 1 Ω
    U7-4 (E) - U7-8 (LDWN)
    UP
    Below 1 Ω
    U7-1 (B) - U7-8 (LDWN)
    UP
    10 kΩ or higher
    U7-4 (E) - U7-7 (LUP)
    UP
    10 kΩ or higher
    U7-4 (E) - U7-7 (LUP)
    OFF
    Below 1 Ω
    U7-4 (E) - U7-8 (LDWN)
    OFF
    Below 1 Ω
    U7-1 (B) - U7-7 (LUP)
    OFF
    10 kΩ or higher
    U7-1 (B) - U7-8 (LDWN)
    OFF
    10 kΩ or higher
    U7-1 (B) - U7-8 (LDWN)
    DOWN
    Below 1 Ω
    U7-4 (E) - U7-7 (LUP)
    DOWN
    Below 1 Ω
    U7-1 (B) - U7-7 (LUP)
    DOWN
    10 kΩ or higher
    U7-4 (E) - U7-8 (LDWN)
    DOWN
    10 kΩ or higher

    Standard resistance (Reclining switch):
    Tester Connection
    Switch Condition
    Specified Condition
    U7-1 (B) - U7-3 (RCLF)
    FRONT
    Below 1 Ω
    U7-4 (E) - U7-2 (RCLR)
    FRONT
    Below 1 Ω
    U7-1 (B) - U7-2 (RCLR)
    FRONT
    10 kΩ or higher
    U7-4 (E) -U7-3 (RCLF)
    FRONT
    10 kΩ or higher
    U7-4 (E) - U7-2 (RCLR)
    OFF
    Below 1 Ω
    U7-4 (E) - U7-3 (RCLF)
    OFF
    Below 1 Ω
    U7-1 (B) - U7-3 (RCLF)
    OFF
    10 kΩ or higher
    U7-1 (B) - U7-2 (RCLR)
    OFF
    10 kΩ or higher
    U7-1 (B) - U7-2 (RCLR)
    REAR
    Below 1 Ω
    U7-4 (E) - U7-3 (RCLF)
    REAR
    Below 1 Ω
    U7-1 (B) - U7-3 (RCLF)
    REAR
    10 kΩ or higher
    U7-4 (E) - U7-2 (RCLR)
    REAR
    10 kΩ or higher

    If the result is not as specified, replace the switch.


INSPECT FRONT POWER SEAT SWITCH RH (for RHD)

  1. B105969E11
    Measure the resistance between the specified terminals when each switch is operated.

    Standard resistance (Slide switch):
    Tester Connection
    Switch Condition
    Specified Condition
    T8-1 (B) - T8-9 (SLDF)
    FRONT
    Below 1 Ω
    T8-4 (E) - T8-6 (SLDR)
    FRONT
    Below 1 Ω
    T8-1 (B) - T8-6 (SLDR)
    FRONT
    10 kΩ or higher
    T8-4 (E) - T8-9 (SLDF)
    FRONT
    10 kΩ or higher
    T8-4 (E) - T8-6 (SLDR)
    OFF
    Below 1 Ω
    T8-4 (E) - T8-9 (SLDF)
    OFF
    Below 1 Ω
    T8-1 (B) - T8-6 (SLDR)
    OFF
    10 kΩ or higher
    T8-1 (B) - T8-9 (SLDF)
    OFF
    10 kΩ or higher
    T8-1 (B) - T8-6 (SLDR)
    REAR
    Below 1 Ω
    T8-4 (E) - T8-9 (SLDF)
    REAR
    Below 1 Ω
    T8-1 (B) - T8-9 (SLDF)
    REAR
    10 kΩ or higher
    T8-4 (E) - T8-6 (SLDR)
    REAR
    10 kΩ or higher

    Standard resistance (Front vertical switch):
    Tester Connection
    Switch Condition
    Specified Condition
    T8-1 (B) - T8-5 (FUP)
    UP
    Below 1 Ω
    T8-4 (E) - T8-10 (FDWN)
    UP
    Below 1 Ω
    T8-1 (B) - T8-10 (FDWN)
    UP
    10 kΩ or higher
    T8-4 (E) - T8-5 (FUP)
    UP
    10 kΩ or higher
    T8-4 (E) - T8-10 (FDWN)
    OFF
    Below 1 Ω
    T8-4 (E) - T8-5 (FUP)
    OFF
    Below 1 Ω
    T8-1 (B) - T8- 10 (FDWN)
    OFF
    10 kΩ or higher
    T8-1 (B) - T8-5 (FUP)
    OFF
    10 kΩ or higher
    T8-1 (B) - T8-10 (FDWN)
    DOWN
    Below 1 Ω
    T8-4 (E) - T8-5 (FUP)
    DOWN
    Below 1 Ω
    T8-1 (B) - T8-5 (FUP)
    DOWN
    10 kΩ or higher
    T8-4 (E) - T8-10 (FDWN)
    DOWN
    10 kΩ or higher

    Standard resistance (Lifter switch):
    Tester Connection
    Switch Condition
    Specified Condition
    T8-1 (B) - T8-8 (LUP)
    UP
    Below 1 Ω
    T8-4 (E) - T8-7 (LDWN)
    UP
    Below 1 Ω
    T8-1 (B) - T8-7 (LDWN)
    UP
    10 kΩ or higher
    T8-4 (E) - T8-8 (LUP)
    UP
    10 kΩ or higher
    T8-4 (E) - T8-8 (LUP)
    OFF
    Below 1 Ω
    T8-4 (E) - T8-7 (LDWN)
    OFF
    Below 1 Ω
    T8-1 (B) - T8-8 (LUP)
    OFF
    10 kΩ or higher
    T8-1 (B) - T8-7 (LDWN)
    OFF
    10 kΩ or higher
    T8-1 (B) - T8-7 (LDWN)
    DOWN
    Below 1 Ω
    T8-4 (E) - T8-8 (LUP)
    DOWN
    Below 1 Ω
    T8-1 (B) - T8-8 (LUP)
    DOWN
    10 kΩ or higher
    T8-4 (E) - T8-7 (LDWN)
    DOWN
    10 kΩ or higher

    Standard resistance (Reclining switch):
    Tester Connection
    Switch Condition
    Specified Condition
    T8-1 (B) - T8-3 (RCLF)
    FRONT
    Below 1 Ω
    T8-4 (E) - T8-2 (RCLR)
    FRONT
    Below 1 Ω
    T8-1 (B) - T8-2 (RCLR)
    FRONT
    10 kΩ or higher
    T8-4 (E) - T8-3 (RCLF)
    FRONT
    10 kΩ or higher
    T8-4 (E) - T8-2 (RCLR)
    OFF
    Below 1 Ω
    T8-4 (E) - T8-3 (RCLF)
    OFF
    Below 1 Ω
    T8-1 (B) - T8- 3 (RCLF)
    OFF
    10 kΩ or higher
    T8-1 (B) - T8-2 (RCLR)
    OFF
    10 kΩ or higher
    T8-1 (B) - T8-2 (RCLR)
    REAR
    Below 1 Ω
    T8-4 (E) - T8-3 (RCLF)
    REAR
    Below 1 Ω
    T8-1 (B) - T8-3 (RCLF)
    REAR
    10 kΩ or higher
    T8-4 (E) - T8-2 (RCLR)
    REAR
    10 kΩ or higher

    If the result is not as specified, replace the switch.


INSPECT FRONT POWER SEAT SWITCH RH (for LHD)

  1. B111877E04
    Measure the resistance between the specified terminals when each switch is operated.

    Standard resistance (Slide switch):
    Tester Connection
    Switch Condition
    Specified Condition
    T8-1 (B) - T8-9 (SLDF)
    FRONT
    Below 1 Ω
    T8-4 (E) - T8-6 (SLDR)
    FRONT
    Below 1 Ω
    T8-1 (B) - T8-6 (SLDR)
    FRONT
    10 kΩ or higher
    T8-4 (E) - T8-9 (SLDF)
    FRONT
    10 kΩ or higher
    T8-4 (E) - T8-6 (SLDR)
    OFF
    Below 1 Ω
    T8-4 (E) - T8-9 (SLDF)
    OFF
    Below 1 Ω
    T8-1 (B) - T8-6 (SLDR)
    OFF
    10 kΩ or higher
    T8-1 (B) - T8-9 (SLDF)
    OFF
    10 kΩ or higher
    T8-1 (B) - T8-6 (SLDR)
    REAR
    Below 1 Ω
    T8-4 (E) - T8-9 (SLDF)
    REAR
    Below 1 Ω
    T8-1 (B) - T8-9 (SLDF)
    REAR
    10 kΩ or higher
    T8-4 (E) - T8-6 (SLDR)
    REAR
    10 kΩ or higher

    Standard resistance (Reclining switch):
    Tester Connection
    Switch Condition
    Specified Condition
    T8-1 (B) - T8-3 (RCLF)
    FRONT
    Below 1 Ω
    T8-4 (E) - T8-2 (RCLR)
    FRONT
    Below 1 Ω
    T8-1 (B) - T8-2 (RCLR)
    FRONT
    10 kΩ or higher
    T8-4 (E) - T8-3 (RCLF)
    FRONT
    10 kΩ or higher
    T8-4 (E) - T8-2 (RCLR)
    OFF
    Below 1 Ω
    T8-4 (E) - T8-3 (RCLF)
    OFF
    Below 1 Ω
    T8-1 (B) - T8- 3 (RCLF)
    OFF
    10 kΩ or higher
    T8-1 (B) - T8-2 (RCLR)
    OFF
    10 kΩ or higher
    T8-1 (B) - T8-2 (RCLR)
    REAR
    Below 1 Ω
    T8-4 (E) - T8-3 (RCLF)
    REAR
    Below 1 Ω
    T8-1 (B) - T8-3 (RCLF)
    REAR
    10 kΩ or higher
    T8-4 (E) - T8-2 (RCLR)
    REAR
    10 kΩ or higher

    If the result is not as specified, replace the switch.


INSPECT FRONT POWER SEAT SWITCH LH (for RHD)

  1. B251404E03
    Measure the resistance between the specified terminals when each switch is operated.

    Standard resistance (Slide switch):
    Tester Connection
    Switch Condition
    Specified Condition
    U7-1 (B) - U7-9 (SLDF)
    FRONT
    Below 1 Ω
    U7-4 (E) - U7-6 (SLDR)
    FRONT
    Below 1 Ω
    U7-1 (B) - U7-6 (SLDR)
    FRONT
    10 kΩ or higher
    U7-4 (E) - U7-9 (SLDF)
    FRONT
    10 kΩ or higher
    U7-4 (E) - U7-6 (SLDR)
    OFF
    Below 1 Ω
    U7-4 (E) - U7-9 (SLDF)
    OFF
    Below 1 Ω
    U7-1 (B) - U7-6 (SLDR)
    OFF
    10 kΩ or higher
    U7-1 (B) - U7-9 (SLDF)
    OFF
    10 kΩ or higher
    U7-1 (B) - U7-6 (SLDR)
    REAR
    Below 1 Ω
    U7-4 (E) - U7-9 (SLDF)
    REAR
    Below 1 Ω
    U7-1 (B) - U7-9 (SLDF)
    REAR
    10 kΩ or higher
    U7-4 (E) - U7-6 (SLDR)
    REAR
    10 kΩ or higher

    Standard resistance (Reclining switch):
    Tester Connection
    Switch Condition
    Specified Condition
    U7-1 (B) - U7-3 (RCLF)
    FRONT
    Below 1 Ω
    U7-4 (E) - U7-2 (RCLR)
    FRONT
    Below 1 Ω
    U7-1 (B) - U7-2 (RCLR)
    FRONT
    10 kΩ or higher
    U7-4 (E) -U7-3 (RCLF)
    FRONT
    10 kΩ or higher
    U7-4 (E) - U7-2 (RCLR)
    OFF
    Below 1 Ω
    U7-4 (E) - U7-3 (RCLF)
    OFF
    Below 1 Ω
    U7-1 (B) - U7-3 (RCLF)
    OFF
    10 kΩ or higher
    U7-1 (B) - U7-2 (RCLR)
    OFF
    10 kΩ or higher
    U7-1 (B) - U7-2 (RCLR)
    REAR
    Below 1 Ω
    U7-4 (E) - U7-3 (RCLF)
    REAR
    Below 1 Ω
    U7-1 (B) - U7-3 (RCLF)
    REAR
    10 kΩ or higher
    U7-4 (E) - U7-2 (RCLR)
    REAR
    10 kΩ or higher

    If the result is not as specified, replace the switch.

← REMOVAL (from Jun 2009)INSTALLATION (Oct 2006 – May 2009) →