INSPECTION
Inspection · Vehicles built from Oct 2006
| INSPECT EXHAUST MANIFOLD SUB-ASSEMBLY LH |
Using a precision straightedge and feeler gauge, measure the warpage on the contact surface of the cylinder head.

- Maximum warpage:
- 0.7 mm (0.028 in.)
- HINT:
- The maximum allowable warpage of each installation surface is 0.3 mm (0.012 in.).
| INSPECT EXHAUST MANIFOLD SUB-ASSEMBLY RH |
Using a precision straightedge and feeler gauge, measure the warpage on the contact surface of the cylinder head.

- Maximum warpage:
- 0.7 mm (0.028 in.)
- HINT:
- The maximum allowable warpage of each installation surface is 0.3 mm (0.012 in.).
| INSPECT INTAKE AIR SURGE TANK ASSEMBLY |
Using a precision straightedge and feeler gauge, measure the warpage on the contact surface of the intake manifold.

- Maximum warpage:
- 2.5 mm (0.098 in.)
If the warpage is greater than the maximum, replace the surge tank.
| INSPECT INTAKE MANIFOLD |
Cylinder head side:

Using a precision straightedge and feeler gauge, measure the surface contacting the cylinder head for warpage.
- Maximum warpage:
- 0.1 mm (0.003 in.)
If the warpage is greater than the maximum, replace the intake manifold.
Surge tank side:
Using a precision straightedge and feeler gauge, measure the surface contacting the surge tank for warpage.
- Maximum warpage:
- 0.1 mm (0.003 in.)
If the warpage is greater than the maximum, replace the intake manifold.
